Skip to main content
Tech Support: (+1) 303-215-9171
|
Sales: (+1) 303-277-1188
| made in usa

220VAC Power Connections: Core End Type and Photo

What type of power cord do I need to run on 220VAC?

220V power cord information.

Systems: All

Epilog's laser systems use auto-switching power supplies accommodating 110 to 240 volts at 50-60Hz. We recommend a dedicated 15A breaker regardless of voltage. If you are going to be running your laser on a 220V and are located in the United States, you will receive a cord with a NEMA L6-15R receptacle (Hubble HBL4570C equivalent). This cord end can also be acquired from a local electrical house or a local hardware store in some cases. A picture has been provided below of both the male and the female sides of this connection.

All international shipments that require a 220V connection will receive a cord with no receptacle on the end so you can dictate which receptacle to use based on local standards.

If further assistance is required, please contact Epilog Laser Technical Support by phone at 303-215-9171, or by email at tech@epiloglaser.com.