{"id":17788,"date":"2024-09-26T00:00:00","date_gmt":"2024-09-26T06:00:00","guid":{"rendered":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/getting-started\/camera-calibration-fusion-maker-edge\/"},"modified":"2026-04-15T11:50:44","modified_gmt":"2026-04-15T17:50:44","slug":"camera-calibration-fusion-maker-edge","status":"publish","type":"post","link":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/calibrations\/camera-calibration-fusion-maker-edge\/","title":{"rendered":"IRIS Camera Calibration Guide"},"content":{"rendered":"<article class=\"uk-article uk-margin-large-bottom\">\n<p class=\"uk-text-meta\"><strong>Estimated Time:<\/strong> 20\u201340 Minutes \u2022 <strong>Skill Level:<\/strong> Intermediate<\/p>\n<div class=\"uk-alert-primary uk-border-rounded\" uk-alert>\n<p><strong>Important:<\/strong> All focus calibration procedures must be completed before performing a camera calibration to ensure accurate results.<\/p>\n<\/p><\/div>\n<p>Click the tabs below to switch between machine types. Each tab shows the camera calibration procedure specific to that machine.<\/p>\n<ul class=\"uk-tab uk-margin-small-bottom\" uk-switcher=\"connect: #calibration-tabs; animation: uk-animation-fade\">\n<li class=\"uk-active\"><a href=\"#\">Overview &#038; Requirements<\/a><\/li>\n<li><a href=\"#\">Fusion Edge (Overhead)<\/a><\/li>\n<li><a href=\"#\">Fusion Pro \/ Ascent<\/a><\/li>\n<\/ul>\n<ul id=\"calibration-tabs\" class=\"uk-switcher uk-margin\">\n<li>\n<div class=\"uk-card uk-card-default uk-card-body uk-border-rounded uk-box-shadow-small\">\n<p>The IRIS camera calibration ensures accurate artwork placement and reliable print-to-cut operations. It should only be completed when specific issues occur or after hardware changes.<\/p>\n<div class=\"uk-grid-divider uk-child-width-1-2@m\" uk-grid>\n<div>\n<p class=\"uk-text-bold\">Perform if you observe:<\/p>\n<ul class=\"uk-list uk-list-bullet\">\n<li>Black camera feed or semi-circle overlay.<\/li>\n<li>Feed rotated 90\u2013180 degrees.<\/li>\n<li>Artwork alignment offset.<\/li>\n<\/ul><\/div>\n<div>\n<p class=\"uk-text-bold\">Perform after changing:<\/p>\n<ul class=\"uk-list uk-list-bullet\">\n<li>Overhead or carriage camera.<\/li>\n<li>Laser focus calibration.<\/li>\n<li>Machine home position.<\/li>\n<\/ul><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/li>\n<li>\n<div class=\"uk-container uk-container-small\">\n<h2 class=\"uk-h3 uk-margin-remove-top\">Overhead Camera Calibration (Fusion Edge)<\/h2>\n<div class=\"uk-margin-small-bottom\">\n<div class=\"uk-card uk-card-default uk-card-body uk-border-rounded uk-card-small\">\n<div class=\"uk-grid-medium uk-flex-middle\" uk-grid>\n<div class=\"uk-width-expand\">\n<h3 class=\"uk-card-title\"><span class=\"uk-badge uk-margin-small-right\">1<\/span> Click the Gear Icon<\/h3>\n<p>Select the <strong>Gear Icon<\/strong> on the home screen to open the settings menu.<\/p>\n<\/p><\/div>\n<div class=\"uk-width-auto@m uk-text-center\">\n                                <img decoding=\"async\" src=\"https:\/\/support.epiloglaser.com\/staging\/assets\/img\/knowledge-base\/display_menus\/home.png\" alt=\"Home Screen\" width=\"180\" class=\"uk-border-rounded\">\n                            <\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"uk-margin-small-bottom\">\n<div class=\"uk-card uk-card-default uk-card-body uk-border-rounded uk-card-small\">\n<div class=\"uk-grid-medium uk-flex-middle\" uk-grid>\n<div class=\"uk-width-expand\">\n<h3 class=\"uk-card-title\"><span class=\"uk-badge uk-margin-small-right\">2<\/span> Long Press &#8220;Settings&#8221;<\/h3>\n<p>Press and hold the title <strong>&#8220;Settings&#8221;<\/strong> for 2-3 seconds to access the advanced settings menu.<\/p>\n<\/p><\/div>\n<div class=\"uk-width-auto@m uk-text-center\">\n                                <img decoding=\"async\" src=\"https:\/\/support.epiloglaser.com\/staging\/assets\/img\/knowledge-base\/display_menus\/settings.png\" alt=\"Long Press Settings\" width=\"180\" class=\"uk-border-rounded\">\n                            <\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"uk-margin-small-bottom\">\n<div class=\"uk-card uk-card-default uk-card-body uk-border-rounded uk-card-small uk-box-shadow-small\">\n<h3 class=\"uk-card-title uk-margin-remove-bottom\"><span class=\"uk-badge uk-margin-small-right\">3<\/span> Calibrate Cameras<\/h3>\n<p class=\"uk-margin-remove-top uk-text-small uk-text-muted\">Choose the path that matches your current firmware version:<\/p>\n<div class=\"uk-child-width-1-2@s uk-grid-small uk-margin-top\" uk-grid>\n<div class=\"uk-text-center\">\n<div class=\"uk-panel uk-background-muted uk-padding-small uk-border-rounded\" style=\"height: 100%;\">\n<div class=\"uk-label uk-margin-small-bottom\">1.1.3.9 or older<\/div>\n<p class=\"uk-text-small uk-text-bold\">Select Calibrate Cameras.<\/p>\n<p>                                    <img decoding=\"async\" src=\"https:\/\/support.epiloglaser.com\/staging\/assets\/img\/knowledge-base\/display_menus\/advanced.png\" width=\"180\" class=\"uk-border-rounded\">\n                                <\/div>\n<\/p><\/div>\n<div class=\"uk-text-center\">\n<div class=\"uk-panel uk-background-muted uk-padding-small uk-border-rounded\" style=\"height: 100%;\">\n<div class=\"uk-label uk-margin-small-bottom\">1.1.4.0 or newer<\/div>\n<p class=\"uk-text-small uk-text-bold\">Select Calibration \u2192 Calibrate Cameras.<\/p>\n<p>                                    <img decoding=\"async\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/advanced_new.png\" width=\"180\" class=\"uk-border-rounded\">\n                                <\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"uk-card uk-card-default uk-card-body uk-border-rounded uk-card-small uk-margin-top\">\n<h3 class=\"uk-card-title\"><span class=\"uk-badge uk-margin-small-right\">4<\/span> Run Calibration<\/h3>\n<ul class=\"uk-list uk-list-bullet\">\n<li><strong>Place Anodized Aluminum:<\/strong> Use 24&#215;12&#8243; sheets (Edge 12: 1, Edge 24: 2, Edge 36: 3).<\/li>\n<li><strong>Start Process:<\/strong> Close the door and press <strong>OK<\/strong>.<\/li>\n<li><strong>Wait:<\/strong> Allow 15\u201330 minutes for analysis.<\/li>\n<li><strong>Verify:<\/strong> Follow prompts to complete calibration.<\/li>\n<\/ul><\/div>\n<\/p><\/div>\n<\/li>\n<li>\n<div class=\"uk-container uk-container-small\">\n<div class=\"uk-card uk-card-default uk-border-rounded uk-margin-medium-bottom uk-box-shadow-small uk-overflow-hidden\">\n<div class=\"uk-grid-collapse uk-child-width-1-2@s uk-flex-middle\" uk-grid>\n<div class=\"uk-background-muted uk-padding-small uk-text-center\">\n                            <img decoding=\"async\" src=\"https:\/\/support.epiloglaser.com\/staging\/assets\/img\/knowledge-base\/camera_calibration\/calibration_mat.png\" alt=\"Calibration mat\" width=\"300\" class=\"uk-border-rounded\">\n                        <\/div>\n<div class=\"uk-padding-small\">\n<h3 class=\"uk-card-title uk-margin-remove-bottom uk-text-bold\">Calibration Mat Required<\/h3>\n<p class=\"uk-text-meta uk-margin-small-top\">An official Epilog Calibration Mat is necessary for the Overhead Camera process.<\/p>\n<div class=\"uk-alert-primary uk-margin-small-top\" uk-alert>\n<p class=\"uk-text-small\">\n                                    <strong>Note:<\/strong> If the mat is curled, allow it to sit on a flat surface until it is <strong>perfectly flat<\/strong>. An unrolled, flat mat is essential for accurate results.\n                                <\/p>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"uk-alert-primary uk-border-rounded uk-margin-medium-bottom\" uk-alert>\n<p class=\"uk-text-bold\"><span uk-icon=\"icon: info; ratio: 0.9\" class=\"uk-margin-small-right\"><\/span>First complete the carriage camera calibration. After finishing, switch to the Overhead tab below.<\/p>\n<\/p><\/div>\n<div class=\"uk-background-muted uk-padding-small uk-border-rounded uk-margin-bottom uk-box-shadow-small\">\n                    <span class=\"uk-text-meta uk-text-uppercase uk-margin-small-bottom uk-display-block uk-text-center\">Select Camera to Calibrate:<\/span><\/p>\n<ul class=\"uk-subnav uk-subnav-pill uk-flex-center uk-grid-small uk-child-width-expand\" uk-grid uk-switcher=\"connect: #pro-subtabs; animation: uk-animation-fade\">\n<li class=\"uk-active\"><a href=\"#\" class=\"uk-box-shadow-small uk-text-center\">Carriage Camera<\/a><\/li>\n<li><a href=\"#\" class=\"uk-box-shadow-small uk-text-center\">Overhead Camera<\/a><\/li>\n<\/ul><\/div>\n<ul id=\"pro-subtabs\" class=\"uk-switcher\">\n<li>\n<div class=\"uk-margin-small-bottom\">\n<div class=\"uk-card uk-card-default uk-card-body uk-border-rounded uk-card-small\">\n<div class=\"uk-grid-medium uk-flex-middle\" uk-grid>\n<div class=\"uk-width-expand\">\n<h3 class=\"uk-card-title\"><span class=\"uk-badge uk-margin-small-right\">1<\/span> Click the Gear Icon<\/h3>\n<p>Select the <strong>Gear Icon<\/strong> on the home screen.<\/p>\n<\/p><\/div>\n<div class=\"uk-width-auto@m\"><img decoding=\"async\" src=\"https:\/\/support.epiloglaser.com\/staging\/assets\/img\/knowledge-base\/display_menus\/home.png\" width=\"150\" class=\"uk-border-rounded\"><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"uk-margin-small-bottom\">\n<div class=\"uk-card uk-card-default uk-card-body uk-border-rounded uk-card-small\">\n<div class=\"uk-grid-medium uk-flex-middle\" uk-grid>\n<div class=\"uk-width-expand\">\n<h3 class=\"uk-card-title\"><span class=\"uk-badge uk-margin-small-right\">2<\/span> Long Press &#8220;Settings&#8221;<\/h3>\n<p>Long press the title <strong>&#8220;Settings&#8221;<\/strong> for 2-3 seconds to access the advanced settings menu.<\/p>\n<\/p><\/div>\n<div class=\"uk-width-auto@m\"><img decoding=\"async\" src=\"https:\/\/support.epiloglaser.com\/staging\/assets\/img\/knowledge-base\/display_menus\/settings.png\" width=\"150\" class=\"uk-border-rounded\"><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"uk-card uk-card-default uk-card-body uk-border-rounded uk-card-small uk-box-shadow-small\">\n<h3 class=\"uk-card-title uk-margin-remove-bottom\"><span class=\"uk-badge uk-margin-small-right\">3<\/span> Select Calibration Path<\/h3>\n<p class=\"uk-margin-remove-top uk-text-small uk-text-muted\">Choose the path that matches your current firmware version:<\/p>\n<div class=\"uk-child-width-1-2@s uk-grid-small uk-margin-top\" uk-grid>\n<div class=\"uk-text-center\">\n<div class=\"uk-panel uk-background-muted uk-padding-small uk-border-rounded\" style=\"height: 100%;\">\n<div class=\"uk-label uk-margin-small-bottom\">1.1.3.9 or older<\/div>\n<p class=\"uk-text-small uk-text-bold\">Tap: Calibrate Cameras<\/p>\n<p>                                        <img decoding=\"async\" src=\"https:\/\/support.epiloglaser.com\/staging\/assets\/img\/knowledge-base\/display_menus\/advanced.png\" width=\"180\" class=\"uk-border-rounded\">\n                                    <\/div>\n<\/p><\/div>\n<div class=\"uk-text-center\">\n<div class=\"uk-panel uk-background-muted uk-padding-small uk-border-rounded\" style=\"height: 100%;\">\n<div class=\"uk-label uk-margin-small-bottom\">1.1.4.0 or newer<\/div>\n<p class=\"uk-text-small uk-text-bold\">Tap: Calibration \u2192 Calibrate<\/p>\n<p>                                        <img decoding=\"async\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/advanced_new.png\" width=\"180\" class=\"uk-border-rounded\">\n                                    <\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"uk-card uk-card-default uk-card-body uk-border-rounded uk-card-small uk-margin-top\">\n<h3 class=\"uk-card-title\"><span class=\"uk-badge uk-margin-small-right\">4<\/span> Engrave Pattern<\/h3>\n<ul class=\"uk-list uk-list-bullet\">\n<li>Place an <strong>8&#8243; \u00d7 5&#8243;<\/strong> piece of anodized aluminum in the upper-left corner.<\/li>\n<li>Close the door and press <strong>OK<\/strong> to engrave the pattern.<\/li>\n<li>Follow prompts to complete calibration.<\/li>\n<\/ul><\/div>\n<\/li>\n<li>\n<div class=\"uk-card uk-card-default uk-card-body uk-border-rounded uk-card-small\">\n<h3 class=\"uk-card-title\">Overhead Calibration Process<\/h3>\n<ol class=\"uk-list uk-list-decimal\">\n<li><strong>Install Mat:<\/strong> Place calibration mat in the upper-left.<\/li>\n<li><strong>Positioning:<\/strong> Ensure the green circle is in the corner.\n<div class=\"uk-margin uk-text-center\"><img decoding=\"async\" src=\"https:\/\/support.epiloglaser.com\/staging\/assets\/img\/knowledge-base\/camera_calibration\/calibration_mat_installed.png\" width=\"400\" class=\"uk-border-rounded uk-box-shadow-small\"><\/div>\n<\/li>\n<li><strong>Run:<\/strong> Close doors and press <strong>OK<\/strong>.\n<li><strong>Verify:<\/strong> Follow prompts to complete calibration.<\/li>\n<\/ol><\/div>\n<\/li>\n<\/ul><\/div>\n<\/li>\n<\/ul>\n<\/article>\n\r\n\t\t\t<div id=\"daexthefu-container\"\r\n\t\t\t\tclass=\"daexthefu-container daexthefu-layout-side-by-side daexthefu-alignment-left\"\r\n\t\t\t\tdata-post-id=\"17788\">\r\n\r\n\t\t\t\t<div class=\"daexthefu-feedback\">\r\n\t\t\t\t\t<div class=\"daexthefu-text\">\r\n\t\t\t\t\t\t<h3 class=\"daexthefu-title\">Was this helpful?<\/h3>\r\n\t\t\t\t\t<\/div>\r\n\t\t\t\t\t<div class=\"daexthefu-buttons-container\">\r\n\t\t\t\t\t\t<div class=\"daexthefu-buttons\">\r\n\t\t\t\t\t\t\t\r\n\t\t\t<div class=\"daexthefu-yes daexthefu-button daexthefu-button-type-text\" data-value=\"1\">\r\n\t\t\t\t<div class=\"daexthefu-button-text\">Yes<\/div>\r\n\t\t\t<\/div>\r\n\r\n\t\t\t\t\t\t\t\t\t\t\r\n\t\t\t<div class=\"daexthefu-no daexthefu-button daexthefu-button-type-text\" data-value=\"0\">\r\n\t\t\t\t<div class=\"daexthefu-button-text\">No<\/div>\r\n\t\t\t<\/div>\r\n\r\n\t\t\t\t\t\t\t\t\t<\/div>\r\n\t\t\t\t\t<\/div>\r\n\t\t\t\t<\/div>\r\n\r\n\t\t\t\t<div class=\"daexthefu-comment\">\r\n\t\t\t\t\t<div class=\"daexthefu-comment-top-container\">\r\n\t\t\t\t\t\t<label id=\"daexthefu-comment-label\" class=\"daexthefu-comment-label\"><\/label>\r\n\t\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"daexthefu-comment-character-counter-container\">\r\n\t\t\t\t\t\t\t\t<div id=\"daexthefu-comment-character-counter-number\"\r\n\t\t\t\t\t\t\t\t\tclass=\"daexthefu-comment-character-counter-number\"><\/div>\r\n\t\t\t\t\t\t\t\t<div class=\"daexthefu-comment-character-counter-text\"><\/div>\r\n\t\t\t\t\t\t\t<\/div>\r\n\t\t\t\t\t\t\t\t\t\t\t<\/div>\r\n\t\t\t\t\t<textarea id=\"daexthefu-comment-textarea\" class=\"daexthefu-comment-textarea\"\r\n\t\t\t\t\t\t\t\tplaceholder=\"Type your message\"\r\n\t\t\t\t\t\t\t\tmaxlength=\"\r\n\t\t\t\t\t\t\t\t400\t\t\t\t\t\t\t\t\t\"><\/textarea>\r\n\t\t\t\t\t<div class=\"daexthefu-comment-buttons-container\">\r\n\t\t\t\t\t\t<button class=\"daexthefu-comment-submit daexthefu-button\">Submit<\/button>\r\n\t\t\t\t\t\t<button class=\"daexthefu-comment-cancel daexthefu-button\">Cancel<\/button>\r\n\t\t\t\t\t<\/div>\r\n\t\t\t\t<\/div>\r\n\r\n\t\t\t\t<div class=\"daexthefu-successful-submission-text\">Thanks for your feedback!<\/div>\r\n\r\n\t\t\t<\/div>\r\n\r\n\t\t\t","protected":false},"excerpt":{"rendered":"<p>Estimated Time: 20\u201340 Minutes \u2022 Skill Level: Intermediate Important: All focus calibration procedures must be completed before performing a camera calibration to ensure accurate results. Click the tabs below to switch between machine types. Each tab shows the camera calibration procedure specific to that machine. Overview &#038; Requirements Fusion Edge (Overhead) Fusion Pro \/ Ascent [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":12726,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_helpful_status":1,"_helpful_pro_status":1,"footnotes":""},"categories":[572,557],"tags":[],"laser_machine":[575,65,66,67],"post_folder":[],"class_list":["post-17788","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-calibrations","category-service-and-repair","laser_machine-fusion-ascent","laser_machine-fusion-pro","laser_machine-fusion-edge","laser_machine-fusion-maker"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.0 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>IRIS Camera Calibration Guide - Epilog Support Center<\/title>\n<meta name=\"description\" content=\"Use this step-by-step guide for camera calibration for your Epilog Fusion Maker and Fusion Edge laser engraving systems.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-edge\/maintenance-cleaning-calibrations\/camera-calibration-fusion-maker-edge\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"IRIS Camera Calibration Guide\" \/>\n<meta property=\"og:description\" content=\"Use this step-by-step guide for camera calibration for your Epilog Fusion Maker and Fusion Edge laser engraving systems.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-edge\/maintenance-cleaning-calibrations\/camera-calibration-fusion-maker-edge\/\" \/>\n<meta property=\"og:site_name\" content=\"Epilog Support Center\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/epiloglaser\" \/>\n<meta property=\"article:published_time\" content=\"2024-09-26T06:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-15T17:50:44+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/fusion-edge_wood-square_25.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"885\" \/>\n\t<meta property=\"og:image:height\" content=\"498\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Billy\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@epiloglaser\" \/>\n<meta name=\"twitter:site\" content=\"@epiloglaser\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Billy\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-edge\\\/maintenance-cleaning-calibrations\\\/camera-calibration-fusion-maker-edge\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-ascent\\\/calibrations\\\/camera-calibration-fusion-maker-edge\\\/\"},\"author\":{\"name\":\"Billy\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#\\\/schema\\\/person\\\/62709b908d1b2e3cef3756c590032c9b\"},\"headline\":\"IRIS Camera Calibration Guide\",\"datePublished\":\"2024-09-26T06:00:00+00:00\",\"dateModified\":\"2026-04-15T17:50:44+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-ascent\\\/calibrations\\\/camera-calibration-fusion-maker-edge\\\/\"},\"wordCount\":376,\"publisher\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-edge\\\/maintenance-cleaning-calibrations\\\/camera-calibration-fusion-maker-edge\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/fusion-edge_wood-square_25.jpg\",\"articleSection\":[\"Calibrations\",\"Service and Repair\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-ascent\\\/calibrations\\\/camera-calibration-fusion-maker-edge\\\/\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-edge\\\/maintenance-cleaning-calibrations\\\/camera-calibration-fusion-maker-edge\\\/\",\"name\":\"IRIS Camera Calibration Guide - Epilog Support Center\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-edge\\\/maintenance-cleaning-calibrations\\\/camera-calibration-fusion-maker-edge\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-edge\\\/maintenance-cleaning-calibrations\\\/camera-calibration-fusion-maker-edge\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/fusion-edge_wood-square_25.jpg\",\"datePublished\":\"2024-09-26T06:00:00+00:00\",\"dateModified\":\"2026-04-15T17:50:44+00:00\",\"description\":\"Use this step-by-step guide for camera calibration for your Epilog Fusion Maker and Fusion Edge laser engraving systems.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-edge\\\/maintenance-cleaning-calibrations\\\/camera-calibration-fusion-maker-edge\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-edge\\\/maintenance-cleaning-calibrations\\\/camera-calibration-fusion-maker-edge\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-edge\\\/maintenance-cleaning-calibrations\\\/camera-calibration-fusion-maker-edge\\\/#primaryimage\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/fusion-edge_wood-square_25.jpg\",\"contentUrl\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/fusion-edge_wood-square_25.jpg\",\"width\":885,\"height\":498},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-edge\\\/maintenance-cleaning-calibrations\\\/camera-calibration-fusion-maker-edge\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"IRIS Camera Calibration Guide\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#website\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/\",\"name\":\"Epilog Support Center\",\"description\":\"Imagine. Design. Create.\",\"publisher\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#organization\",\"name\":\"Epilog Laser\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/epilog-logo.png\",\"contentUrl\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/epilog-logo.png\",\"width\":215,\"height\":46,\"caption\":\"Epilog Laser\"},\"image\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/epiloglaser\",\"https:\\\/\\\/x.com\\\/epiloglaser\",\"https:\\\/\\\/www.instagram.com\\\/epiloglaser\\\/\",\"https:\\\/\\\/www.youtube.com\\\/@epiloglaser\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/epilog\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#\\\/schema\\\/person\\\/62709b908d1b2e3cef3756c590032c9b\",\"name\":\"Billy\",\"sameAs\":[\"https:\\\/\\\/support.epiloglaser.com\\\/staging\"],\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/author\\\/kbtest\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"IRIS Camera Calibration Guide - Epilog Support Center","description":"Use this step-by-step guide for camera calibration for your Epilog Fusion Maker and Fusion Edge laser engraving systems.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-edge\/maintenance-cleaning-calibrations\/camera-calibration-fusion-maker-edge\/","og_locale":"en_US","og_type":"article","og_title":"IRIS Camera Calibration Guide","og_description":"Use this step-by-step guide for camera calibration for your Epilog Fusion Maker and Fusion Edge laser engraving systems.","og_url":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-edge\/maintenance-cleaning-calibrations\/camera-calibration-fusion-maker-edge\/","og_site_name":"Epilog Support Center","article_publisher":"https:\/\/www.facebook.com\/epiloglaser","article_published_time":"2024-09-26T06:00:00+00:00","article_modified_time":"2026-04-15T17:50:44+00:00","og_image":[{"width":885,"height":498,"url":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/fusion-edge_wood-square_25.jpg","type":"image\/jpeg"}],"author":"Billy","twitter_card":"summary_large_image","twitter_creator":"@epiloglaser","twitter_site":"@epiloglaser","twitter_misc":{"Written by":"Billy","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-edge\/maintenance-cleaning-calibrations\/camera-calibration-fusion-maker-edge\/#article","isPartOf":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/calibrations\/camera-calibration-fusion-maker-edge\/"},"author":{"name":"Billy","@id":"https:\/\/support.epiloglaser.com\/staging\/#\/schema\/person\/62709b908d1b2e3cef3756c590032c9b"},"headline":"IRIS Camera Calibration Guide","datePublished":"2024-09-26T06:00:00+00:00","dateModified":"2026-04-15T17:50:44+00:00","mainEntityOfPage":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/calibrations\/camera-calibration-fusion-maker-edge\/"},"wordCount":376,"publisher":{"@id":"https:\/\/support.epiloglaser.com\/staging\/#organization"},"image":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-edge\/maintenance-cleaning-calibrations\/camera-calibration-fusion-maker-edge\/#primaryimage"},"thumbnailUrl":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/fusion-edge_wood-square_25.jpg","articleSection":["Calibrations","Service and Repair"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/calibrations\/camera-calibration-fusion-maker-edge\/","url":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-edge\/maintenance-cleaning-calibrations\/camera-calibration-fusion-maker-edge\/","name":"IRIS Camera Calibration Guide - Epilog Support Center","isPartOf":{"@id":"https:\/\/support.epiloglaser.com\/staging\/#website"},"primaryImageOfPage":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-edge\/maintenance-cleaning-calibrations\/camera-calibration-fusion-maker-edge\/#primaryimage"},"image":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-edge\/maintenance-cleaning-calibrations\/camera-calibration-fusion-maker-edge\/#primaryimage"},"thumbnailUrl":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/fusion-edge_wood-square_25.jpg","datePublished":"2024-09-26T06:00:00+00:00","dateModified":"2026-04-15T17:50:44+00:00","description":"Use this step-by-step guide for camera calibration for your Epilog Fusion Maker and Fusion Edge laser engraving systems.","breadcrumb":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-edge\/maintenance-cleaning-calibrations\/camera-calibration-fusion-maker-edge\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-edge\/maintenance-cleaning-calibrations\/camera-calibration-fusion-maker-edge\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-edge\/maintenance-cleaning-calibrations\/camera-calibration-fusion-maker-edge\/#primaryimage","url":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/fusion-edge_wood-square_25.jpg","contentUrl":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/fusion-edge_wood-square_25.jpg","width":885,"height":498},{"@type":"BreadcrumbList","@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-edge\/maintenance-cleaning-calibrations\/camera-calibration-fusion-maker-edge\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/support.epiloglaser.com\/staging\/"},{"@type":"ListItem","position":2,"name":"IRIS Camera Calibration Guide"}]},{"@type":"WebSite","@id":"https:\/\/support.epiloglaser.com\/staging\/#website","url":"https:\/\/support.epiloglaser.com\/staging\/","name":"Epilog Support Center","description":"Imagine. Design. Create.","publisher":{"@id":"https:\/\/support.epiloglaser.com\/staging\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/support.epiloglaser.com\/staging\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/support.epiloglaser.com\/staging\/#organization","name":"Epilog Laser","url":"https:\/\/support.epiloglaser.com\/staging\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/support.epiloglaser.com\/staging\/#\/schema\/logo\/image\/","url":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/epilog-logo.png","contentUrl":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/epilog-logo.png","width":215,"height":46,"caption":"Epilog Laser"},"image":{"@id":"https:\/\/support.epiloglaser.com\/staging\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/epiloglaser","https:\/\/x.com\/epiloglaser","https:\/\/www.instagram.com\/epiloglaser\/","https:\/\/www.youtube.com\/@epiloglaser","https:\/\/www.linkedin.com\/company\/epilog"]},{"@type":"Person","@id":"https:\/\/support.epiloglaser.com\/staging\/#\/schema\/person\/62709b908d1b2e3cef3756c590032c9b","name":"Billy","sameAs":["https:\/\/support.epiloglaser.com\/staging"],"url":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/author\/kbtest\/"}]}},"_links":{"self":[{"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/posts\/17788","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/comments?post=17788"}],"version-history":[{"count":15,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/posts\/17788\/revisions"}],"predecessor-version":[{"id":21549,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/posts\/17788\/revisions\/21549"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/media\/12726"}],"wp:attachment":[{"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/media?parent=17788"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/categories?post=17788"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/tags?post=17788"},{"taxonomy":"laser_machine","embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/laser_machine?post=17788"},{"taxonomy":"post_folder","embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/post_folder?post=17788"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}