{"id":18082,"date":"2024-09-24T00:00:00","date_gmt":"2024-09-24T06:00:00","guid":{"rendered":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/getting-started\/x-axis-air-assist-aa-tubing-replacement-fusion-pro-32-48\/"},"modified":"2025-10-23T13:48:26","modified_gmt":"2025-10-23T19:48:26","slug":"x-axis-air-assist-aa-tubing-replacement-fusion-pro-32-48","status":"publish","type":"post","link":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/service-and-repair\/x-axis-air-assist-aa-tubing-replacement-fusion-pro-32-48\/","title":{"rendered":"X-Axis Air Assist (AA) Tubing Replacement &#8211; Fusion Pro 32 &#038; 48"},"content":{"rendered":"<p>The X-Axis Air Assist (AA) Tubing Replacement process for the Fusion Pro 32 and 48 engravers ensures proper air flow during operation. Over time, the tubing may wear out and require replacement to maintain optimal performance. This guide provides step-by-step instructions on how to safely remove and install new AA tubing using the required tools and materials. By following these procedures, users can help ensure their engraver continues to function efficiently.<\/p>\n<h2>X-Axis AA Tubing Removal<\/h2>\n<ol class=\"uk-list uk-list-decimal uk-list-divider uk-list-large\">\n<li>Turn off the engraver.<\/li>\n<li>Disconnect engraver from power source.<\/li>\n<li>Remove the right panel of the engraver.<\/li>\n<li>Remove the nine (9) Torx screws that secure the carriage assembly cover and remove the cover.<br \/>\n\t\t<img decoding=\"async\" class=\"uk-margin-bottom\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/16k_air_assist_tubing_001.png\" alt= \"screenshot\"><\/li>\n<li>Remove the carriage cover.<br \/>\n\t\t<img decoding=\"async\" class=\"uk-margin-bottom\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/16k_air_assist_tubing_002.png\" alt= \"screenshot\"><\/li>\n<li>Disconnect the AA tubing from the connector on the carriage assembly.<br \/>\n\t\t<img decoding=\"async\" class=\"uk-margin-bottom\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/16k_air_assist_tubing_003.png\" alt= \"screenshot\"><\/li>\n<li>Disconnect the lens camera PCB USB cable.<br \/>\n\t\t<img decoding=\"async\" class=\"uk-margin-bottom\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/16k_air_assist_tubing_004.png\" alt= \"screenshot\"><\/li>\n<li>Loosen and remove the two (2) Phillips screws that secure the cable track to the rear of the x-axis assembly.<br \/>\n\t\t<img decoding=\"async\" class=\"uk-margin-bottom\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/16k_air_assist_tubing_005.png\" alt= \"screenshot\"><\/li>\n<li>Pull the cable track to the left side of the machine to straighten it.\n\t\t<\/li>\n<li>\n<p>Pull the AA tubing towards the right side of the machine to remove it from the cable track.<\/p>\n<div class=\"uk-panel uk-tile-muted uk-padding\">\n<p><i><strong><span class=\"uk-text-primary uk-h4\"><i class=\"fas fa-exclamation-circle uk-margin-small-right\"><\/i>Note: <\/span><\/strong>The AA tubing and carriage camera USB cable may be ziptied to the x-axis assembly in certain points. If this is the case, remove the zipties and replace them once the installation of the AA tubing is complete. Take care not to over-tighten the zipties.<\/i><\/p>\n<\/div>\n<\/li>\n<li>Disconnect the AA tubing from the elbow connector at right side of the x-axis assembly. \t<img decoding=\"async\" class=\"uk-margin-bottom\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/16k_air_assist_tubing_006.png\" alt= \"screenshot\"><\/li>\n<li>Remove the AA tubing from the engraver.<\/li>\n<\/ol>\n<h2>X-Axis AA Tubing Installation<\/h2>\n<ol class=\"uk-list uk-list-decimal uk-list-divider uk-list-large\">\n<li>Connect the AA tubing to the elbow connector at right side of the x-axis assembly.<br \/>\n\t\t<img decoding=\"async\" class=\"uk-margin-bottom\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/16k_air_assist_tubing_006.png\" alt= \"screenshot\"><\/li>\n<li>Route the AA tubing through the opening on the right side of the x-axis assembly.<\/li>\n<li>Insert the AA tubing into the right side of the cable track and push it towards the left side.<\/li>\n<li>Place the cable track into position and tighten the two (2) Phillips screws that secure the cable track to the rear of the x-axis assembly.<br \/>\n\t\t<img decoding=\"async\" class=\"uk-margin-bottom\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/16k_air_assist_tubing_005.png\" alt= \"screenshot\"><\/li>\n<li>Connect the camera board USB cable.<br \/>\n\t\t<img decoding=\"async\" class=\"uk-margin-bottom\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/16k_air_assist_tubing_007.png\" alt= \"screenshot\"><\/li>\n<li>Connect the AA tubing to the connector on the carriage assembly.<br \/>\n\t\t<img decoding=\"async\" class=\"uk-margin-bottom\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/16k_air_assist_tubing_008.png\" alt= \"screenshot\"><\/li>\n<li>Install the carriage cover<br \/>\n\t\t<img decoding=\"async\" class=\"uk-margin-bottom\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/16k_air_assist_tubing_002.png\" alt= \"screenshot\">.<\/li>\n<li>Install and tighten the nine (9) Torx screws on the carriage cover.<br \/>\n\t\t<img decoding=\"async\" class=\"uk-margin-bottom\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/16k_air_assist_tubing_001.png\" alt= \"screenshot\"><\/li>\n<li>Replace the right panel of the engraver.<\/li>\n<\/ol>\n\r\n\t\t\t<div id=\"daexthefu-container\"\r\n\t\t\t\tclass=\"daexthefu-container daexthefu-layout-side-by-side daexthefu-alignment-left\"\r\n\t\t\t\tdata-post-id=\"18082\">\r\n\r\n\t\t\t\t<div class=\"daexthefu-feedback\">\r\n\t\t\t\t\t<div class=\"daexthefu-text\">\r\n\t\t\t\t\t\t<h3 class=\"daexthefu-title\">Was this helpful?<\/h3>\r\n\t\t\t\t\t<\/div>\r\n\t\t\t\t\t<div class=\"daexthefu-buttons-container\">\r\n\t\t\t\t\t\t<div class=\"daexthefu-buttons\">\r\n\t\t\t\t\t\t\t\r\n\t\t\t<div class=\"daexthefu-yes daexthefu-button daexthefu-button-type-text\" data-value=\"1\">\r\n\t\t\t\t<div class=\"daexthefu-button-text\">Yes<\/div>\r\n\t\t\t<\/div>\r\n\r\n\t\t\t\t\t\t\t\t\t\t\r\n\t\t\t<div class=\"daexthefu-no daexthefu-button daexthefu-button-type-text\" data-value=\"0\">\r\n\t\t\t\t<div class=\"daexthefu-button-text\">No<\/div>\r\n\t\t\t<\/div>\r\n\r\n\t\t\t\t\t\t\t\t\t<\/div>\r\n\t\t\t\t\t<\/div>\r\n\t\t\t\t<\/div>\r\n\r\n\t\t\t\t<div class=\"daexthefu-comment\">\r\n\t\t\t\t\t<div class=\"daexthefu-comment-top-container\">\r\n\t\t\t\t\t\t<label id=\"daexthefu-comment-label\" class=\"daexthefu-comment-label\"><\/label>\r\n\t\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"daexthefu-comment-character-counter-container\">\r\n\t\t\t\t\t\t\t\t<div id=\"daexthefu-comment-character-counter-number\"\r\n\t\t\t\t\t\t\t\t\tclass=\"daexthefu-comment-character-counter-number\"><\/div>\r\n\t\t\t\t\t\t\t\t<div class=\"daexthefu-comment-character-counter-text\"><\/div>\r\n\t\t\t\t\t\t\t<\/div>\r\n\t\t\t\t\t\t\t\t\t\t\t<\/div>\r\n\t\t\t\t\t<textarea id=\"daexthefu-comment-textarea\" class=\"daexthefu-comment-textarea\"\r\n\t\t\t\t\t\t\t\tplaceholder=\"Type your message\"\r\n\t\t\t\t\t\t\t\tmaxlength=\"\r\n\t\t\t\t\t\t\t\t400\t\t\t\t\t\t\t\t\t\"><\/textarea>\r\n\t\t\t\t\t<div class=\"daexthefu-comment-buttons-container\">\r\n\t\t\t\t\t\t<button class=\"daexthefu-comment-submit daexthefu-button\">Submit<\/button>\r\n\t\t\t\t\t\t<button class=\"daexthefu-comment-cancel daexthefu-button\">Cancel<\/button>\r\n\t\t\t\t\t<\/div>\r\n\t\t\t\t<\/div>\r\n\r\n\t\t\t\t<div class=\"daexthefu-successful-submission-text\">Thanks for your feedback!<\/div>\r\n\r\n\t\t\t<\/div>\r\n\r\n\t\t\t","protected":false},"excerpt":{"rendered":"<p>The X-Axis Air Assist (AA) Tubing Replacement process for the Fusion Pro 32 and 48 engravers ensures proper air flow during operation. Over time, the tubing may wear out and require replacement to maintain optimal performance. This guide provides step-by-step instructions on how to safely remove and install new AA tubing using the required tools [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":11400,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_helpful_status":1,"_helpful_pro_status":1,"footnotes":""},"categories":[557,558],"tags":[],"laser_machine":[65],"post_folder":[],"class_list":["post-18082","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-service-and-repair","category-x-axis","laser_machine-fusion-pro"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.0 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>X-Axis Air Assist (AA) Tubing Replacement - Fusion Pro 32 &amp; 48 - Epilog Support Center<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/service-and-repair\/x-axis-air-assist-aa-tubing-replacement-fusion-pro-32-48\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"X-Axis Air Assist (AA) Tubing Replacement - Fusion Pro 32 &amp; 48\" \/>\n<meta property=\"og:description\" content=\"The X-Axis Air Assist (AA) Tubing Replacement process for the Fusion Pro 32 and 48 engravers ensures proper air flow during operation. Over time, the tubing may wear out and require replacement to maintain optimal performance. This guide provides step-by-step instructions on how to safely remove and install new AA tubing using the required tools [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/service-and-repair\/x-axis-air-assist-aa-tubing-replacement-fusion-pro-32-48\/\" \/>\n<meta property=\"og:site_name\" content=\"Epilog Support Center\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/epiloglaser\" \/>\n<meta property=\"article:published_time\" content=\"2024-09-24T06:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-10-23T19:48:26+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/fusion-pro_replacing-optics_16.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"830\" \/>\n\t<meta property=\"og:image:height\" content=\"467\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Billy\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@epiloglaser\" \/>\n<meta name=\"twitter:site\" content=\"@epiloglaser\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Billy\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-pro\\\/service-and-repair\\\/x-axis-air-assist-aa-tubing-replacement-fusion-pro-32-48\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-pro\\\/service-and-repair\\\/x-axis-air-assist-aa-tubing-replacement-fusion-pro-32-48\\\/\"},\"author\":{\"name\":\"Billy\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#\\\/schema\\\/person\\\/62709b908d1b2e3cef3756c590032c9b\"},\"headline\":\"X-Axis Air Assist (AA) Tubing Replacement &#8211; Fusion Pro 32 &#038; 48\",\"datePublished\":\"2024-09-24T06:00:00+00:00\",\"dateModified\":\"2025-10-23T19:48:26+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-pro\\\/service-and-repair\\\/x-axis-air-assist-aa-tubing-replacement-fusion-pro-32-48\\\/\"},\"wordCount\":370,\"publisher\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-pro\\\/service-and-repair\\\/x-axis-air-assist-aa-tubing-replacement-fusion-pro-32-48\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/fusion-pro_replacing-optics_16.jpg\",\"articleSection\":[\"Service and Repair\",\"X-Axis\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-pro\\\/service-and-repair\\\/x-axis-air-assist-aa-tubing-replacement-fusion-pro-32-48\\\/\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-pro\\\/service-and-repair\\\/x-axis-air-assist-aa-tubing-replacement-fusion-pro-32-48\\\/\",\"name\":\"X-Axis Air Assist (AA) Tubing Replacement - Fusion Pro 32 & 48 - Epilog Support Center\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-pro\\\/service-and-repair\\\/x-axis-air-assist-aa-tubing-replacement-fusion-pro-32-48\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-pro\\\/service-and-repair\\\/x-axis-air-assist-aa-tubing-replacement-fusion-pro-32-48\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/fusion-pro_replacing-optics_16.jpg\",\"datePublished\":\"2024-09-24T06:00:00+00:00\",\"dateModified\":\"2025-10-23T19:48:26+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-pro\\\/service-and-repair\\\/x-axis-air-assist-aa-tubing-replacement-fusion-pro-32-48\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-pro\\\/service-and-repair\\\/x-axis-air-assist-aa-tubing-replacement-fusion-pro-32-48\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-pro\\\/service-and-repair\\\/x-axis-air-assist-aa-tubing-replacement-fusion-pro-32-48\\\/#primaryimage\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/fusion-pro_replacing-optics_16.jpg\",\"contentUrl\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/fusion-pro_replacing-optics_16.jpg\",\"width\":830,\"height\":467},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-pro\\\/service-and-repair\\\/x-axis-air-assist-aa-tubing-replacement-fusion-pro-32-48\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"X-Axis Air Assist (AA) Tubing Replacement &#8211; Fusion Pro 32 &#038; 48\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#website\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/\",\"name\":\"Epilog Support Center\",\"description\":\"Imagine. Design. Create.\",\"publisher\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#organization\",\"name\":\"Epilog Laser\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/epilog-logo.png\",\"contentUrl\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/epilog-logo.png\",\"width\":215,\"height\":46,\"caption\":\"Epilog Laser\"},\"image\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/epiloglaser\",\"https:\\\/\\\/x.com\\\/epiloglaser\",\"https:\\\/\\\/www.instagram.com\\\/epiloglaser\\\/\",\"https:\\\/\\\/www.youtube.com\\\/@epiloglaser\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/epilog\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#\\\/schema\\\/person\\\/62709b908d1b2e3cef3756c590032c9b\",\"name\":\"Billy\",\"sameAs\":[\"https:\\\/\\\/support.epiloglaser.com\\\/staging\"],\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/author\\\/kbtest\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"X-Axis Air Assist (AA) Tubing Replacement - Fusion Pro 32 & 48 - Epilog Support Center","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/service-and-repair\/x-axis-air-assist-aa-tubing-replacement-fusion-pro-32-48\/","og_locale":"en_US","og_type":"article","og_title":"X-Axis Air Assist (AA) Tubing Replacement - Fusion Pro 32 & 48","og_description":"The X-Axis Air Assist (AA) Tubing Replacement process for the Fusion Pro 32 and 48 engravers ensures proper air flow during operation. Over time, the tubing may wear out and require replacement to maintain optimal performance. This guide provides step-by-step instructions on how to safely remove and install new AA tubing using the required tools [&hellip;]","og_url":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/service-and-repair\/x-axis-air-assist-aa-tubing-replacement-fusion-pro-32-48\/","og_site_name":"Epilog Support Center","article_publisher":"https:\/\/www.facebook.com\/epiloglaser","article_published_time":"2024-09-24T06:00:00+00:00","article_modified_time":"2025-10-23T19:48:26+00:00","og_image":[{"width":830,"height":467,"url":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/fusion-pro_replacing-optics_16.jpg","type":"image\/jpeg"}],"author":"Billy","twitter_card":"summary_large_image","twitter_creator":"@epiloglaser","twitter_site":"@epiloglaser","twitter_misc":{"Written by":"Billy","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/service-and-repair\/x-axis-air-assist-aa-tubing-replacement-fusion-pro-32-48\/#article","isPartOf":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/service-and-repair\/x-axis-air-assist-aa-tubing-replacement-fusion-pro-32-48\/"},"author":{"name":"Billy","@id":"https:\/\/support.epiloglaser.com\/staging\/#\/schema\/person\/62709b908d1b2e3cef3756c590032c9b"},"headline":"X-Axis Air Assist (AA) Tubing Replacement &#8211; Fusion Pro 32 &#038; 48","datePublished":"2024-09-24T06:00:00+00:00","dateModified":"2025-10-23T19:48:26+00:00","mainEntityOfPage":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/service-and-repair\/x-axis-air-assist-aa-tubing-replacement-fusion-pro-32-48\/"},"wordCount":370,"publisher":{"@id":"https:\/\/support.epiloglaser.com\/staging\/#organization"},"image":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/service-and-repair\/x-axis-air-assist-aa-tubing-replacement-fusion-pro-32-48\/#primaryimage"},"thumbnailUrl":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/fusion-pro_replacing-optics_16.jpg","articleSection":["Service and Repair","X-Axis"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/service-and-repair\/x-axis-air-assist-aa-tubing-replacement-fusion-pro-32-48\/","url":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/service-and-repair\/x-axis-air-assist-aa-tubing-replacement-fusion-pro-32-48\/","name":"X-Axis Air Assist (AA) Tubing Replacement - Fusion Pro 32 & 48 - Epilog Support Center","isPartOf":{"@id":"https:\/\/support.epiloglaser.com\/staging\/#website"},"primaryImageOfPage":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/service-and-repair\/x-axis-air-assist-aa-tubing-replacement-fusion-pro-32-48\/#primaryimage"},"image":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/service-and-repair\/x-axis-air-assist-aa-tubing-replacement-fusion-pro-32-48\/#primaryimage"},"thumbnailUrl":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/fusion-pro_replacing-optics_16.jpg","datePublished":"2024-09-24T06:00:00+00:00","dateModified":"2025-10-23T19:48:26+00:00","breadcrumb":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/service-and-repair\/x-axis-air-assist-aa-tubing-replacement-fusion-pro-32-48\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/service-and-repair\/x-axis-air-assist-aa-tubing-replacement-fusion-pro-32-48\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/service-and-repair\/x-axis-air-assist-aa-tubing-replacement-fusion-pro-32-48\/#primaryimage","url":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/fusion-pro_replacing-optics_16.jpg","contentUrl":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/fusion-pro_replacing-optics_16.jpg","width":830,"height":467},{"@type":"BreadcrumbList","@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/service-and-repair\/x-axis-air-assist-aa-tubing-replacement-fusion-pro-32-48\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/support.epiloglaser.com\/staging\/"},{"@type":"ListItem","position":2,"name":"X-Axis Air Assist (AA) Tubing Replacement &#8211; Fusion Pro 32 &#038; 48"}]},{"@type":"WebSite","@id":"https:\/\/support.epiloglaser.com\/staging\/#website","url":"https:\/\/support.epiloglaser.com\/staging\/","name":"Epilog Support Center","description":"Imagine. Design. Create.","publisher":{"@id":"https:\/\/support.epiloglaser.com\/staging\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/support.epiloglaser.com\/staging\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/support.epiloglaser.com\/staging\/#organization","name":"Epilog Laser","url":"https:\/\/support.epiloglaser.com\/staging\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/support.epiloglaser.com\/staging\/#\/schema\/logo\/image\/","url":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/epilog-logo.png","contentUrl":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/epilog-logo.png","width":215,"height":46,"caption":"Epilog Laser"},"image":{"@id":"https:\/\/support.epiloglaser.com\/staging\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/epiloglaser","https:\/\/x.com\/epiloglaser","https:\/\/www.instagram.com\/epiloglaser\/","https:\/\/www.youtube.com\/@epiloglaser","https:\/\/www.linkedin.com\/company\/epilog"]},{"@type":"Person","@id":"https:\/\/support.epiloglaser.com\/staging\/#\/schema\/person\/62709b908d1b2e3cef3756c590032c9b","name":"Billy","sameAs":["https:\/\/support.epiloglaser.com\/staging"],"url":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/author\/kbtest\/"}]}},"_links":{"self":[{"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/posts\/18082","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/comments?post=18082"}],"version-history":[{"count":8,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/posts\/18082\/revisions"}],"predecessor-version":[{"id":20882,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/posts\/18082\/revisions\/20882"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/media\/11400"}],"wp:attachment":[{"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/media?parent=18082"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/categories?post=18082"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/tags?post=18082"},{"taxonomy":"laser_machine","embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/laser_machine?post=18082"},{"taxonomy":"post_folder","embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/post_folder?post=18082"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}