{"id":19125,"date":"2025-04-11T10:12:36","date_gmt":"2025-04-11T16:12:36","guid":{"rendered":"https:\/\/support.epiloglaser.com\/staging\/?p=19125"},"modified":"2025-04-11T10:48:30","modified_gmt":"2025-04-11T16:48:30","slug":"autofocus-plunger-replacement","status":"publish","type":"post","link":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/legend-36ext\/service-and-repair\/autofocus-plunger-replacement\/","title":{"rendered":"Autofocus Plunger Replacement &#8211; Legend 36EXT"},"content":{"rendered":"<p>This document outlines the step-by-step procedure for replacing the Auto Focus sensor on the Epilog Legend EXT laser system. Before beginning, make sure the machine is powered off to ensure safety during the process. Familiarity with the X-carriage assembly is recommended; refer to the exploded view diagram for part identification as needed. By following the instructions carefully, users can safely and effectively install a new Auto Focus sensor and restore proper machine functionality.<\/p>\n<p>Please see the attachment for the detailed procedure.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>This document outlines the step-by-step procedure for replacing the Auto Focus sensor on the Epilog Legend EXT laser system. Before beginning, make sure the machine is powered off to ensure safety during the process. Familiarity with the X-carriage assembly is recommended; refer to the exploded view diagram for part identification as needed. By following the [&hellip;]<\/p>\n","protected":false},"author":5,"featured_media":1593,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[557,558],"tags":[],"laser_machine":[73],"post_folder":[],"class_list":["post-19125","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-service-and-repair","category-x-axis","laser_machine-legend-36ext"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.0 (Yoast SEO v28.1) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Autofocus Plunger Replacement - Legend 36EXT - Epilog Support Center<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/legend-36ext\/service-and-repair\/autofocus-plunger-replacement\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Autofocus Plunger Replacement - Legend 36EXT\" \/>\n<meta property=\"og:description\" content=\"This document outlines the step-by-step procedure for replacing the Auto Focus sensor on the Epilog Legend EXT laser system. Before beginning, make sure the machine is powered off to ensure safety during the process. Familiarity with the X-carriage assembly is recommended; refer to the exploded view diagram for part identification as needed. By following the [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/legend-36ext\/service-and-repair\/autofocus-plunger-replacement\/\" \/>\n<meta property=\"og:site_name\" content=\"Epilog Support Center\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/epiloglaser\" \/>\n<meta property=\"article:published_time\" content=\"2025-04-11T16:12:36+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-04-11T16:48:30+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/legend-36ext.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"400\" \/>\n\t<meta property=\"og:image:height\" content=\"300\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Tyler Brock\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@epiloglaser\" \/>\n<meta name=\"twitter:site\" content=\"@epiloglaser\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Tyler Brock\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/legend-36ext\\\/service-and-repair\\\/autofocus-plunger-replacement\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/legend-36ext\\\/service-and-repair\\\/autofocus-plunger-replacement\\\/\"},\"author\":{\"name\":\"Tyler Brock\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#\\\/schema\\\/person\\\/db690367f94e26f7d0b8f3bb258d4cdd\"},\"headline\":\"Autofocus Plunger Replacement &#8211; Legend 36EXT\",\"datePublished\":\"2025-04-11T16:12:36+00:00\",\"dateModified\":\"2025-04-11T16:48:30+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/legend-36ext\\\/service-and-repair\\\/autofocus-plunger-replacement\\\/\"},\"wordCount\":87,\"publisher\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/legend-36ext\\\/service-and-repair\\\/autofocus-plunger-replacement\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/legend-36ext.jpg\",\"articleSection\":[\"Service and Repair\",\"X-Axis\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/legend-36ext\\\/service-and-repair\\\/autofocus-plunger-replacement\\\/\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/legend-36ext\\\/service-and-repair\\\/autofocus-plunger-replacement\\\/\",\"name\":\"Autofocus Plunger Replacement - Legend 36EXT - Epilog Support Center\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/legend-36ext\\\/service-and-repair\\\/autofocus-plunger-replacement\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/legend-36ext\\\/service-and-repair\\\/autofocus-plunger-replacement\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/legend-36ext.jpg\",\"datePublished\":\"2025-04-11T16:12:36+00:00\",\"dateModified\":\"2025-04-11T16:48:30+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/legend-36ext\\\/service-and-repair\\\/autofocus-plunger-replacement\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/legend-36ext\\\/service-and-repair\\\/autofocus-plunger-replacement\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/legend-36ext\\\/service-and-repair\\\/autofocus-plunger-replacement\\\/#primaryimage\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/legend-36ext.jpg\",\"contentUrl\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/legend-36ext.jpg\",\"width\":400,\"height\":300},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/legend-36ext\\\/service-and-repair\\\/autofocus-plunger-replacement\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Autofocus Plunger Replacement &#8211; Legend 36EXT\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#website\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/\",\"name\":\"Epilog Support Center\",\"description\":\"Imagine. Design. Create.\",\"publisher\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#organization\",\"name\":\"Epilog Laser\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/epilog-logo.png\",\"contentUrl\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/epilog-logo.png\",\"width\":215,\"height\":46,\"caption\":\"Epilog Laser\"},\"image\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/epiloglaser\",\"https:\\\/\\\/x.com\\\/epiloglaser\",\"https:\\\/\\\/www.instagram.com\\\/epiloglaser\\\/\",\"https:\\\/\\\/www.youtube.com\\\/@epiloglaser\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/epilog\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#\\\/schema\\\/person\\\/db690367f94e26f7d0b8f3bb258d4cdd\",\"name\":\"Tyler Brock\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/author\\\/tyler\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Autofocus Plunger Replacement - Legend 36EXT - Epilog Support Center","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/legend-36ext\/service-and-repair\/autofocus-plunger-replacement\/","og_locale":"en_US","og_type":"article","og_title":"Autofocus Plunger Replacement - Legend 36EXT","og_description":"This document outlines the step-by-step procedure for replacing the Auto Focus sensor on the Epilog Legend EXT laser system. Before beginning, make sure the machine is powered off to ensure safety during the process. Familiarity with the X-carriage assembly is recommended; refer to the exploded view diagram for part identification as needed. By following the [&hellip;]","og_url":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/legend-36ext\/service-and-repair\/autofocus-plunger-replacement\/","og_site_name":"Epilog Support Center","article_publisher":"https:\/\/www.facebook.com\/epiloglaser","article_published_time":"2025-04-11T16:12:36+00:00","article_modified_time":"2025-04-11T16:48:30+00:00","og_image":[{"width":400,"height":300,"url":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/legend-36ext.jpg","type":"image\/jpeg"}],"author":"Tyler Brock","twitter_card":"summary_large_image","twitter_creator":"@epiloglaser","twitter_site":"@epiloglaser","twitter_misc":{"Written by":"Tyler Brock","Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/legend-36ext\/service-and-repair\/autofocus-plunger-replacement\/#article","isPartOf":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/legend-36ext\/service-and-repair\/autofocus-plunger-replacement\/"},"author":{"name":"Tyler Brock","@id":"https:\/\/support.epiloglaser.com\/staging\/#\/schema\/person\/db690367f94e26f7d0b8f3bb258d4cdd"},"headline":"Autofocus Plunger Replacement &#8211; Legend 36EXT","datePublished":"2025-04-11T16:12:36+00:00","dateModified":"2025-04-11T16:48:30+00:00","mainEntityOfPage":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/legend-36ext\/service-and-repair\/autofocus-plunger-replacement\/"},"wordCount":87,"publisher":{"@id":"https:\/\/support.epiloglaser.com\/staging\/#organization"},"image":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/legend-36ext\/service-and-repair\/autofocus-plunger-replacement\/#primaryimage"},"thumbnailUrl":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/legend-36ext.jpg","articleSection":["Service and Repair","X-Axis"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/legend-36ext\/service-and-repair\/autofocus-plunger-replacement\/","url":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/legend-36ext\/service-and-repair\/autofocus-plunger-replacement\/","name":"Autofocus Plunger Replacement - Legend 36EXT - Epilog Support Center","isPartOf":{"@id":"https:\/\/support.epiloglaser.com\/staging\/#website"},"primaryImageOfPage":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/legend-36ext\/service-and-repair\/autofocus-plunger-replacement\/#primaryimage"},"image":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/legend-36ext\/service-and-repair\/autofocus-plunger-replacement\/#primaryimage"},"thumbnailUrl":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/legend-36ext.jpg","datePublished":"2025-04-11T16:12:36+00:00","dateModified":"2025-04-11T16:48:30+00:00","breadcrumb":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/legend-36ext\/service-and-repair\/autofocus-plunger-replacement\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/support.epiloglaser.com\/staging\/laser-machine\/legend-36ext\/service-and-repair\/autofocus-plunger-replacement\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/legend-36ext\/service-and-repair\/autofocus-plunger-replacement\/#primaryimage","url":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/legend-36ext.jpg","contentUrl":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/legend-36ext.jpg","width":400,"height":300},{"@type":"BreadcrumbList","@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/legend-36ext\/service-and-repair\/autofocus-plunger-replacement\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/support.epiloglaser.com\/staging\/"},{"@type":"ListItem","position":2,"name":"Autofocus Plunger Replacement &#8211; Legend 36EXT"}]},{"@type":"WebSite","@id":"https:\/\/support.epiloglaser.com\/staging\/#website","url":"https:\/\/support.epiloglaser.com\/staging\/","name":"Epilog Support Center","description":"Imagine. Design. Create.","publisher":{"@id":"https:\/\/support.epiloglaser.com\/staging\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/support.epiloglaser.com\/staging\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/support.epiloglaser.com\/staging\/#organization","name":"Epilog Laser","url":"https:\/\/support.epiloglaser.com\/staging\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/support.epiloglaser.com\/staging\/#\/schema\/logo\/image\/","url":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/epilog-logo.png","contentUrl":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/epilog-logo.png","width":215,"height":46,"caption":"Epilog Laser"},"image":{"@id":"https:\/\/support.epiloglaser.com\/staging\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/epiloglaser","https:\/\/x.com\/epiloglaser","https:\/\/www.instagram.com\/epiloglaser\/","https:\/\/www.youtube.com\/@epiloglaser","https:\/\/www.linkedin.com\/company\/epilog"]},{"@type":"Person","@id":"https:\/\/support.epiloglaser.com\/staging\/#\/schema\/person\/db690367f94e26f7d0b8f3bb258d4cdd","name":"Tyler Brock","url":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/author\/tyler\/"}]}},"_links":{"self":[{"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/posts\/19125","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/comments?post=19125"}],"version-history":[{"count":3,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/posts\/19125\/revisions"}],"predecessor-version":[{"id":19136,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/posts\/19125\/revisions\/19136"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/media\/1593"}],"wp:attachment":[{"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/media?parent=19125"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/categories?post=19125"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/tags?post=19125"},{"taxonomy":"laser_machine","embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/laser_machine?post=19125"},{"taxonomy":"post_folder","embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/post_folder?post=19125"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}