{"id":19240,"date":"2025-04-21T12:14:45","date_gmt":"2025-04-21T18:14:45","guid":{"rendered":"https:\/\/support.epiloglaser.com\/staging\/?p=19240"},"modified":"2025-12-31T10:17:00","modified_gmt":"2025-12-31T17:17:00","slug":"manual-focus-gauge-calibration-fusion-maker-edge-pro","status":"publish","type":"post","link":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-edge\/calibrations\/manual-focus-gauge-calibration-fusion-maker-edge-pro\/","title":{"rendered":"Manual Focus Gauge Calibration &#8211; Fusion Maker, Edge, Pro"},"content":{"rendered":"<p>This procedure outlines the steps required to calibrate the manual focus gauge after completing the Focus Calibration Wizard. Proper calibration ensures that the gauge accurately reflects the correct focal height determined using the Calibration Wizard.<\/p>\n<div class=\"uk-alert-primary uk-padding-small uk-margin-small-top\" uk-alert>\n      <strong>Note:<\/strong> The Calibration Wizard is available only on firmware version 1.1.2.1 or later. To update your firmware, navigate to Support &gt; Software and Firmware Downloads.\n    <\/div>\n<h2>Calibrating the Manual Focus Gauge<\/h2>\n<ol class=\"uk-list-decimal uk-list-divider uk-margin-top\">\n<li>\n<p>After completing the Focus Calibration Wizard, jog the carriage so it is positioned above the engraved anodized aluminum test pattern.<\/p>\n<p>\t<img decoding=\"async\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/calibrating_focus_gauge_001.png\" alt=\"jog carriage over anodized\"> <\/li>\n<li>\n<p>Press <strong>Auto Focus<\/strong>.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/calibrating_focus_gauge_004.png\" alt=\"press autofocus\"><\/li>\n<li>\n<p>Place the manual focus gauge on the carriage in its designated mounting location.<\/p>\n<p>\t<img decoding=\"async\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/calibrating_focus_gauge_002.png\" alt=\"focus gauge on carriage\"> <\/li>\n<li>\n<p>Verify that the tip of the focus tool makes light contact with the surface of the material.<\/p>\n<p>\t<img decoding=\"async\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/calibrating_focus_gauge_008.png\" alt=\"tool touching material\"> <\/li>\n<li>\n<p>If adjustment is needed, loosen the two brass fittings located at the end of the gauge.<\/p>\n<p>\t  \t<img decoding=\"async\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/calibrating_focus_gauge_003.png\" alt=\"adjust brass fittings\"><\/li>\n<li>\n<p>Turn the lower brass fitting to raise or lower the gauge until the tip lightly touches the material.<\/p>\n<p>\t  \t<img decoding=\"async\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/calibrating_focus_gauge_005.png\" alt=\"loosen brass fitting\"><\/li>\n<li>\n<p>Verify that the tip of the focus tool makes light contact with the surface of the material.<\/p>\n<p>\t<img decoding=\"async\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/calibrating_focus_gauge_008.png\" alt=\"tool touching material\"> <\/li>\n<li>\n<p>Once the correct height is set, hold the bottom fitting and tighten the upper brass fitting.<\/p>\n<p>\t  \t<img decoding=\"async\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/calibrating_focus_gauge_006.png\" alt=\"tighten brass fitting\"><\/li>\n<\/ol>\n\r\n\t\t\t<div id=\"daexthefu-container\"\r\n\t\t\t\tclass=\"daexthefu-container daexthefu-layout-side-by-side daexthefu-alignment-left\"\r\n\t\t\t\tdata-post-id=\"19240\">\r\n\r\n\t\t\t\t<div class=\"daexthefu-feedback\">\r\n\t\t\t\t\t<div class=\"daexthefu-text\">\r\n\t\t\t\t\t\t<h3 class=\"daexthefu-title\">Was this helpful?<\/h3>\r\n\t\t\t\t\t<\/div>\r\n\t\t\t\t\t<div class=\"daexthefu-buttons-container\">\r\n\t\t\t\t\t\t<div class=\"daexthefu-buttons\">\r\n\t\t\t\t\t\t\t\r\n\t\t\t<div class=\"daexthefu-yes daexthefu-button daexthefu-button-type-text\" data-value=\"1\">\r\n\t\t\t\t<div class=\"daexthefu-button-text\">Yes<\/div>\r\n\t\t\t<\/div>\r\n\r\n\t\t\t\t\t\t\t\t\t\t\r\n\t\t\t<div class=\"daexthefu-no daexthefu-button daexthefu-button-type-text\" data-value=\"0\">\r\n\t\t\t\t<div class=\"daexthefu-button-text\">No<\/div>\r\n\t\t\t<\/div>\r\n\r\n\t\t\t\t\t\t\t\t\t<\/div>\r\n\t\t\t\t\t<\/div>\r\n\t\t\t\t<\/div>\r\n\r\n\t\t\t\t<div class=\"daexthefu-comment\">\r\n\t\t\t\t\t<div class=\"daexthefu-comment-top-container\">\r\n\t\t\t\t\t\t<label id=\"daexthefu-comment-label\" class=\"daexthefu-comment-label\"><\/label>\r\n\t\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"daexthefu-comment-character-counter-container\">\r\n\t\t\t\t\t\t\t\t<div id=\"daexthefu-comment-character-counter-number\"\r\n\t\t\t\t\t\t\t\t\tclass=\"daexthefu-comment-character-counter-number\"><\/div>\r\n\t\t\t\t\t\t\t\t<div class=\"daexthefu-comment-character-counter-text\"><\/div>\r\n\t\t\t\t\t\t\t<\/div>\r\n\t\t\t\t\t\t\t\t\t\t\t<\/div>\r\n\t\t\t\t\t<textarea id=\"daexthefu-comment-textarea\" class=\"daexthefu-comment-textarea\"\r\n\t\t\t\t\t\t\t\tplaceholder=\"Type your message\"\r\n\t\t\t\t\t\t\t\tmaxlength=\"\r\n\t\t\t\t\t\t\t\t400\t\t\t\t\t\t\t\t\t\"><\/textarea>\r\n\t\t\t\t\t<div class=\"daexthefu-comment-buttons-container\">\r\n\t\t\t\t\t\t<button class=\"daexthefu-comment-submit daexthefu-button\">Submit<\/button>\r\n\t\t\t\t\t\t<button class=\"daexthefu-comment-cancel daexthefu-button\">Cancel<\/button>\r\n\t\t\t\t\t<\/div>\r\n\t\t\t\t<\/div>\r\n\r\n\t\t\t\t<div class=\"daexthefu-successful-submission-text\">Thanks for your feedback!<\/div>\r\n\r\n\t\t\t<\/div>\r\n\r\n\t\t\t","protected":false},"excerpt":{"rendered":"<p>This procedure outlines the steps required to calibrate the manual focus gauge after completing the Focus Calibration Wizard. Proper calibration ensures that the gauge accurately reflects the correct focal height determined using the Calibration Wizard. Note: The Calibration Wizard is available only on firmware version 1.1.2.1 or later. To update your firmware, navigate to Support [&hellip;]<\/p>\n","protected":false},"author":5,"featured_media":10891,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_helpful_status":1,"_helpful_pro_status":1,"footnotes":""},"categories":[572,557],"tags":[],"laser_machine":[65,66,67],"post_folder":[],"class_list":["post-19240","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-calibrations","category-service-and-repair","laser_machine-fusion-pro","laser_machine-fusion-edge","laser_machine-fusion-maker"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.0 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Manual Focus Gauge Calibration - Fusion Maker, Edge, Pro - Epilog Support Center<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/maintenance-cleaning-calibrations\/manual-focus-gauge-calibration-fusion-maker-edge-pro\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Manual Focus Gauge Calibration - Fusion Maker, Edge, Pro\" \/>\n<meta property=\"og:description\" content=\"This procedure outlines the steps required to calibrate the manual focus gauge after completing the Focus Calibration Wizard. Proper calibration ensures that the gauge accurately reflects the correct focal height determined using the Calibration Wizard. Note: The Calibration Wizard is available only on firmware version 1.1.2.1 or later. To update your firmware, navigate to Support [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/maintenance-cleaning-calibrations\/manual-focus-gauge-calibration-fusion-maker-edge-pro\/\" \/>\n<meta property=\"og:site_name\" content=\"Epilog Support Center\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/epiloglaser\" \/>\n<meta property=\"article:published_time\" content=\"2025-04-21T18:14:45+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-12-31T17:17:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/fusion-edge_optics_17.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"830\" \/>\n\t<meta property=\"og:image:height\" content=\"467\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Tyler Brock\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@epiloglaser\" \/>\n<meta name=\"twitter:site\" content=\"@epiloglaser\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Tyler Brock\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-pro\\\/maintenance-cleaning-calibrations\\\/manual-focus-gauge-calibration-fusion-maker-edge-pro\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-edge\\\/calibrations\\\/manual-focus-gauge-calibration-fusion-maker-edge-pro\\\/\"},\"author\":{\"name\":\"Tyler Brock\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#\\\/schema\\\/person\\\/db690367f94e26f7d0b8f3bb258d4cdd\"},\"headline\":\"Manual Focus Gauge Calibration &#8211; Fusion Maker, Edge, Pro\",\"datePublished\":\"2025-04-21T18:14:45+00:00\",\"dateModified\":\"2025-12-31T17:17:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-edge\\\/calibrations\\\/manual-focus-gauge-calibration-fusion-maker-edge-pro\\\/\"},\"wordCount\":193,\"publisher\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-pro\\\/maintenance-cleaning-calibrations\\\/manual-focus-gauge-calibration-fusion-maker-edge-pro\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/fusion-edge_optics_17.jpg\",\"articleSection\":[\"Calibrations\",\"Service and Repair\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-edge\\\/calibrations\\\/manual-focus-gauge-calibration-fusion-maker-edge-pro\\\/\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-pro\\\/maintenance-cleaning-calibrations\\\/manual-focus-gauge-calibration-fusion-maker-edge-pro\\\/\",\"name\":\"Manual Focus Gauge Calibration - Fusion Maker, Edge, Pro - Epilog Support Center\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-pro\\\/maintenance-cleaning-calibrations\\\/manual-focus-gauge-calibration-fusion-maker-edge-pro\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-pro\\\/maintenance-cleaning-calibrations\\\/manual-focus-gauge-calibration-fusion-maker-edge-pro\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/fusion-edge_optics_17.jpg\",\"datePublished\":\"2025-04-21T18:14:45+00:00\",\"dateModified\":\"2025-12-31T17:17:00+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-pro\\\/maintenance-cleaning-calibrations\\\/manual-focus-gauge-calibration-fusion-maker-edge-pro\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-pro\\\/maintenance-cleaning-calibrations\\\/manual-focus-gauge-calibration-fusion-maker-edge-pro\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-pro\\\/maintenance-cleaning-calibrations\\\/manual-focus-gauge-calibration-fusion-maker-edge-pro\\\/#primaryimage\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/fusion-edge_optics_17.jpg\",\"contentUrl\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/fusion-edge_optics_17.jpg\",\"width\":830,\"height\":467},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-pro\\\/maintenance-cleaning-calibrations\\\/manual-focus-gauge-calibration-fusion-maker-edge-pro\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Manual Focus Gauge Calibration &#8211; Fusion Maker, Edge, Pro\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#website\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/\",\"name\":\"Epilog Support Center\",\"description\":\"Imagine. Design. Create.\",\"publisher\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#organization\",\"name\":\"Epilog Laser\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/epilog-logo.png\",\"contentUrl\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/epilog-logo.png\",\"width\":215,\"height\":46,\"caption\":\"Epilog Laser\"},\"image\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/epiloglaser\",\"https:\\\/\\\/x.com\\\/epiloglaser\",\"https:\\\/\\\/www.instagram.com\\\/epiloglaser\\\/\",\"https:\\\/\\\/www.youtube.com\\\/@epiloglaser\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/epilog\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#\\\/schema\\\/person\\\/db690367f94e26f7d0b8f3bb258d4cdd\",\"name\":\"Tyler Brock\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/author\\\/tyler\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Manual Focus Gauge Calibration - Fusion Maker, Edge, Pro - Epilog Support Center","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/maintenance-cleaning-calibrations\/manual-focus-gauge-calibration-fusion-maker-edge-pro\/","og_locale":"en_US","og_type":"article","og_title":"Manual Focus Gauge Calibration - Fusion Maker, Edge, Pro","og_description":"This procedure outlines the steps required to calibrate the manual focus gauge after completing the Focus Calibration Wizard. Proper calibration ensures that the gauge accurately reflects the correct focal height determined using the Calibration Wizard. Note: The Calibration Wizard is available only on firmware version 1.1.2.1 or later. To update your firmware, navigate to Support [&hellip;]","og_url":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/maintenance-cleaning-calibrations\/manual-focus-gauge-calibration-fusion-maker-edge-pro\/","og_site_name":"Epilog Support Center","article_publisher":"https:\/\/www.facebook.com\/epiloglaser","article_published_time":"2025-04-21T18:14:45+00:00","article_modified_time":"2025-12-31T17:17:00+00:00","og_image":[{"width":830,"height":467,"url":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/fusion-edge_optics_17.jpg","type":"image\/jpeg"}],"author":"Tyler Brock","twitter_card":"summary_large_image","twitter_creator":"@epiloglaser","twitter_site":"@epiloglaser","twitter_misc":{"Written by":"Tyler Brock","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/maintenance-cleaning-calibrations\/manual-focus-gauge-calibration-fusion-maker-edge-pro\/#article","isPartOf":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-edge\/calibrations\/manual-focus-gauge-calibration-fusion-maker-edge-pro\/"},"author":{"name":"Tyler Brock","@id":"https:\/\/support.epiloglaser.com\/staging\/#\/schema\/person\/db690367f94e26f7d0b8f3bb258d4cdd"},"headline":"Manual Focus Gauge Calibration &#8211; Fusion Maker, Edge, Pro","datePublished":"2025-04-21T18:14:45+00:00","dateModified":"2025-12-31T17:17:00+00:00","mainEntityOfPage":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-edge\/calibrations\/manual-focus-gauge-calibration-fusion-maker-edge-pro\/"},"wordCount":193,"publisher":{"@id":"https:\/\/support.epiloglaser.com\/staging\/#organization"},"image":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/maintenance-cleaning-calibrations\/manual-focus-gauge-calibration-fusion-maker-edge-pro\/#primaryimage"},"thumbnailUrl":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/fusion-edge_optics_17.jpg","articleSection":["Calibrations","Service and Repair"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-edge\/calibrations\/manual-focus-gauge-calibration-fusion-maker-edge-pro\/","url":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/maintenance-cleaning-calibrations\/manual-focus-gauge-calibration-fusion-maker-edge-pro\/","name":"Manual Focus Gauge Calibration - Fusion Maker, Edge, Pro - Epilog Support Center","isPartOf":{"@id":"https:\/\/support.epiloglaser.com\/staging\/#website"},"primaryImageOfPage":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/maintenance-cleaning-calibrations\/manual-focus-gauge-calibration-fusion-maker-edge-pro\/#primaryimage"},"image":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/maintenance-cleaning-calibrations\/manual-focus-gauge-calibration-fusion-maker-edge-pro\/#primaryimage"},"thumbnailUrl":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/fusion-edge_optics_17.jpg","datePublished":"2025-04-21T18:14:45+00:00","dateModified":"2025-12-31T17:17:00+00:00","breadcrumb":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/maintenance-cleaning-calibrations\/manual-focus-gauge-calibration-fusion-maker-edge-pro\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/maintenance-cleaning-calibrations\/manual-focus-gauge-calibration-fusion-maker-edge-pro\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/maintenance-cleaning-calibrations\/manual-focus-gauge-calibration-fusion-maker-edge-pro\/#primaryimage","url":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/fusion-edge_optics_17.jpg","contentUrl":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/fusion-edge_optics_17.jpg","width":830,"height":467},{"@type":"BreadcrumbList","@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/maintenance-cleaning-calibrations\/manual-focus-gauge-calibration-fusion-maker-edge-pro\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/support.epiloglaser.com\/staging\/"},{"@type":"ListItem","position":2,"name":"Manual Focus Gauge Calibration &#8211; Fusion Maker, Edge, Pro"}]},{"@type":"WebSite","@id":"https:\/\/support.epiloglaser.com\/staging\/#website","url":"https:\/\/support.epiloglaser.com\/staging\/","name":"Epilog Support Center","description":"Imagine. Design. Create.","publisher":{"@id":"https:\/\/support.epiloglaser.com\/staging\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/support.epiloglaser.com\/staging\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/support.epiloglaser.com\/staging\/#organization","name":"Epilog Laser","url":"https:\/\/support.epiloglaser.com\/staging\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/support.epiloglaser.com\/staging\/#\/schema\/logo\/image\/","url":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/epilog-logo.png","contentUrl":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/epilog-logo.png","width":215,"height":46,"caption":"Epilog Laser"},"image":{"@id":"https:\/\/support.epiloglaser.com\/staging\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/epiloglaser","https:\/\/x.com\/epiloglaser","https:\/\/www.instagram.com\/epiloglaser\/","https:\/\/www.youtube.com\/@epiloglaser","https:\/\/www.linkedin.com\/company\/epilog"]},{"@type":"Person","@id":"https:\/\/support.epiloglaser.com\/staging\/#\/schema\/person\/db690367f94e26f7d0b8f3bb258d4cdd","name":"Tyler Brock","url":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/author\/tyler\/"}]}},"_links":{"self":[{"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/posts\/19240","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/comments?post=19240"}],"version-history":[{"count":8,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/posts\/19240\/revisions"}],"predecessor-version":[{"id":19409,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/posts\/19240\/revisions\/19409"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/media\/10891"}],"wp:attachment":[{"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/media?parent=19240"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/categories?post=19240"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/tags?post=19240"},{"taxonomy":"laser_machine","embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/laser_machine?post=19240"},{"taxonomy":"post_folder","embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/post_folder?post=19240"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}