{"id":19714,"date":"2025-05-30T10:04:18","date_gmt":"2025-05-30T16:04:18","guid":{"rendered":"https:\/\/support.epiloglaser.com\/staging\/?p=19714"},"modified":"2025-05-30T10:05:14","modified_gmt":"2025-05-30T16:05:14","slug":"autofocus-switch-replacement-pro-48-large-aperture","status":"publish","type":"post","link":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/service-and-repair\/autofocus-switch-replacement-pro-48-large-aperture\/","title":{"rendered":"Autofocus Switch Replacement &#8211; Pro 48 (Large Aperture)"},"content":{"rendered":"<p>This guide provides step-by-step instructions for replacing the Autofocus Switch in a large aperture Fusion Pro 48 laser system. It includes all necessary removal and installation steps, along with the required tools and parts. Be sure to follow safety precautions and power off the machine before beginning any maintenance work.<\/p>\n<h2 class=\"uk-heading-bullet\">Removal<\/h2>\n<ol class=\"uk-list uk-list-decimal uk-list-divider uk-list-large\">\n<li>\n<p>Power off the machine and disconnect the power cable.<\/p>\n<p>    <img decoding=\"async\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/pro48_x_motor_large_aperture_001.png\" alt=\"Powering off and unplugging the Fusion Pro 48 laser system\" class=\"uk-margin-small\">\n  <\/li>\n<li>\n<p>Move the X-Axis rail to the center of the machine.<\/p>\n<p>    <img decoding=\"async\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/pro48_x_motor_large_aperture_003.png\" alt=\"X-axis rail centered in Fusion Pro 48\" class=\"uk-margin-small\">\n  <\/li>\n<li>\n<p>Move the carriage to the center of the machine.<\/p>\n<p>    <img decoding=\"async\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/pro48_af_switch_large_aperture_001.png\" alt=\"Carriage positioned at center of X-axis rail\" class=\"uk-margin-small\">\n  <\/li>\n<li>\n<p>Remove the carriage camera cover.<\/p>\n<p>    <img decoding=\"async\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/pro48_af_switch_large_aperture_002.png\" alt=\"Removing carriage camera cover \u2013 front view\" class=\"uk-margin-small\"><br \/>\n    <img decoding=\"async\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/pro48_af_switch_large_aperture_003.png\" alt=\"Removing carriage camera cover \u2013 side view\" class=\"uk-margin-small\">\n  <\/li>\n<li>\n<p>Disconnect the electrical harness to the Autofocus Switch.<\/p>\n<p>    <img decoding=\"async\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/pro48_af_switch_large_aperture_004.png\" alt=\"Disconnecting Autofocus Switch electrical harness\" class=\"uk-margin-small\">\n  <\/li>\n<li>\n<p>Remove the screw securing the Autofocus Switch.<\/p>\n<p>    <img decoding=\"async\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/pro48_af_switch_large_aperture_005.png\" alt=\"Removing Autofocus Switch screw from carriage\" class=\"uk-margin-small\">\n  <\/li>\n<\/ol>\n<h2 class=\"uk-heading-bullet\">Installation<\/h2>\n<ol class=\"uk-list uk-list-decimal uk-list-large uk-list-divider\">\n<li>\n<p>Install the Autofocus Switch onto the carriage.<\/p>\n<p>    <img decoding=\"async\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/pro48_af_switch_large_aperture_006.png\" alt=\"Installing Autofocus Switch on Fusion Pro 48 carriage\" class=\"uk-margin-small\">\n  <\/li>\n<li>\n<p>Reconnect the electrical harness to the Autofocus Switch.<\/p>\n<p>    <img decoding=\"async\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/pro48_af_switch_large_aperture_007.png\" alt=\"Reconnecting Autofocus Switch electrical harness\" class=\"uk-margin-small\">\n  <\/li>\n<li>\n<p>Reattach the carriage camera cover.<\/p>\n<p>    <img decoding=\"async\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/pro48_af_switch_large_aperture_008.png\" alt=\"Attaching carriage camera cover \u2013 front view\" class=\"uk-margin-small\"><br \/>\n    <img decoding=\"async\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/pro48_af_switch_large_aperture_009.png\" alt=\"Attaching carriage camera cover \u2013 top view\" class=\"uk-margin-small\">\n  <\/li>\n<\/ol>\n\r\n\t\t\t<div id=\"daexthefu-container\"\r\n\t\t\t\tclass=\"daexthefu-container daexthefu-layout-side-by-side daexthefu-alignment-left\"\r\n\t\t\t\tdata-post-id=\"19714\">\r\n\r\n\t\t\t\t<div class=\"daexthefu-feedback\">\r\n\t\t\t\t\t<div class=\"daexthefu-text\">\r\n\t\t\t\t\t\t<h3 class=\"daexthefu-title\">Was this helpful?<\/h3>\r\n\t\t\t\t\t<\/div>\r\n\t\t\t\t\t<div class=\"daexthefu-buttons-container\">\r\n\t\t\t\t\t\t<div class=\"daexthefu-buttons\">\r\n\t\t\t\t\t\t\t\r\n\t\t\t<div class=\"daexthefu-yes daexthefu-button daexthefu-button-type-text\" data-value=\"1\">\r\n\t\t\t\t<div class=\"daexthefu-button-text\">Yes<\/div>\r\n\t\t\t<\/div>\r\n\r\n\t\t\t\t\t\t\t\t\t\t\r\n\t\t\t<div class=\"daexthefu-no daexthefu-button daexthefu-button-type-text\" data-value=\"0\">\r\n\t\t\t\t<div class=\"daexthefu-button-text\">No<\/div>\r\n\t\t\t<\/div>\r\n\r\n\t\t\t\t\t\t\t\t\t<\/div>\r\n\t\t\t\t\t<\/div>\r\n\t\t\t\t<\/div>\r\n\r\n\t\t\t\t<div class=\"daexthefu-comment\">\r\n\t\t\t\t\t<div class=\"daexthefu-comment-top-container\">\r\n\t\t\t\t\t\t<label id=\"daexthefu-comment-label\" class=\"daexthefu-comment-label\"><\/label>\r\n\t\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"daexthefu-comment-character-counter-container\">\r\n\t\t\t\t\t\t\t\t<div id=\"daexthefu-comment-character-counter-number\"\r\n\t\t\t\t\t\t\t\t\tclass=\"daexthefu-comment-character-counter-number\"><\/div>\r\n\t\t\t\t\t\t\t\t<div class=\"daexthefu-comment-character-counter-text\"><\/div>\r\n\t\t\t\t\t\t\t<\/div>\r\n\t\t\t\t\t\t\t\t\t\t\t<\/div>\r\n\t\t\t\t\t<textarea id=\"daexthefu-comment-textarea\" class=\"daexthefu-comment-textarea\"\r\n\t\t\t\t\t\t\t\tplaceholder=\"Type your message\"\r\n\t\t\t\t\t\t\t\tmaxlength=\"\r\n\t\t\t\t\t\t\t\t400\t\t\t\t\t\t\t\t\t\"><\/textarea>\r\n\t\t\t\t\t<div class=\"daexthefu-comment-buttons-container\">\r\n\t\t\t\t\t\t<button class=\"daexthefu-comment-submit daexthefu-button\">Submit<\/button>\r\n\t\t\t\t\t\t<button class=\"daexthefu-comment-cancel daexthefu-button\">Cancel<\/button>\r\n\t\t\t\t\t<\/div>\r\n\t\t\t\t<\/div>\r\n\r\n\t\t\t\t<div class=\"daexthefu-successful-submission-text\">Thanks for your feedback!<\/div>\r\n\r\n\t\t\t<\/div>\r\n\r\n\t\t\t","protected":false},"excerpt":{"rendered":"<p>This guide provides step-by-step instructions for replacing the Autofocus Switch in a large aperture Fusion Pro 48 laser system. It includes all necessary removal and installation steps, along with the required tools and parts. Be sure to follow safety precautions and power off the machine before beginning any maintenance work. Removal Power off the machine [&hellip;]<\/p>\n","protected":false},"author":5,"featured_media":11750,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_helpful_status":1,"_helpful_pro_status":1,"footnotes":""},"categories":[557,558],"tags":[],"laser_machine":[65],"post_folder":[],"class_list":["post-19714","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-service-and-repair","category-x-axis","laser_machine-fusion-pro"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.0 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Autofocus Switch Replacement - Pro 48 (Large Aperture) - Epilog Support Center<\/title>\n<meta name=\"description\" content=\"Step-by-step guide to replacing the Autofocus Switch in a Fusion Pro 48 large aperture laser system, with images and installation details\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/service-and-repair\/autofocus-switch-replacement-pro-48-large-aperture\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Autofocus Switch Replacement - Pro 48 (Large Aperture)\" \/>\n<meta property=\"og:description\" content=\"Step-by-step guide to replacing the Autofocus Switch in a Fusion Pro 48 large aperture laser system, with images and installation details\" \/>\n<meta property=\"og:url\" content=\"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/service-and-repair\/autofocus-switch-replacement-pro-48-large-aperture\/\" \/>\n<meta property=\"og:site_name\" content=\"Epilog Support Center\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/epiloglaser\" \/>\n<meta property=\"article:published_time\" content=\"2025-05-30T16:04:18+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-05-30T16:05:14+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/fusion-pro_x-axis-tensioning-belt_01.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"1080\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Tyler Brock\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@epiloglaser\" \/>\n<meta name=\"twitter:site\" content=\"@epiloglaser\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Tyler Brock\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-pro\\\/service-and-repair\\\/autofocus-switch-replacement-pro-48-large-aperture\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-pro\\\/service-and-repair\\\/autofocus-switch-replacement-pro-48-large-aperture\\\/\"},\"author\":{\"name\":\"Tyler Brock\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#\\\/schema\\\/person\\\/db690367f94e26f7d0b8f3bb258d4cdd\"},\"headline\":\"Autofocus Switch Replacement &#8211; Pro 48 (Large Aperture)\",\"datePublished\":\"2025-05-30T16:04:18+00:00\",\"dateModified\":\"2025-05-30T16:05:14+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-pro\\\/service-and-repair\\\/autofocus-switch-replacement-pro-48-large-aperture\\\/\"},\"wordCount\":126,\"publisher\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-pro\\\/service-and-repair\\\/autofocus-switch-replacement-pro-48-large-aperture\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/fusion-pro_x-axis-tensioning-belt_01.jpg\",\"articleSection\":[\"Service and Repair\",\"X-Axis\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-pro\\\/service-and-repair\\\/autofocus-switch-replacement-pro-48-large-aperture\\\/\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-pro\\\/service-and-repair\\\/autofocus-switch-replacement-pro-48-large-aperture\\\/\",\"name\":\"Autofocus Switch Replacement - Pro 48 (Large Aperture) - Epilog Support Center\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-pro\\\/service-and-repair\\\/autofocus-switch-replacement-pro-48-large-aperture\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-pro\\\/service-and-repair\\\/autofocus-switch-replacement-pro-48-large-aperture\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/fusion-pro_x-axis-tensioning-belt_01.jpg\",\"datePublished\":\"2025-05-30T16:04:18+00:00\",\"dateModified\":\"2025-05-30T16:05:14+00:00\",\"description\":\"Step-by-step guide to replacing the Autofocus Switch in a Fusion Pro 48 large aperture laser system, with images and installation details\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-pro\\\/service-and-repair\\\/autofocus-switch-replacement-pro-48-large-aperture\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-pro\\\/service-and-repair\\\/autofocus-switch-replacement-pro-48-large-aperture\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-pro\\\/service-and-repair\\\/autofocus-switch-replacement-pro-48-large-aperture\\\/#primaryimage\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/fusion-pro_x-axis-tensioning-belt_01.jpg\",\"contentUrl\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/fusion-pro_x-axis-tensioning-belt_01.jpg\",\"width\":1920,\"height\":1080},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-pro\\\/service-and-repair\\\/autofocus-switch-replacement-pro-48-large-aperture\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Autofocus Switch Replacement &#8211; Pro 48 (Large Aperture)\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#website\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/\",\"name\":\"Epilog Support Center\",\"description\":\"Imagine. Design. Create.\",\"publisher\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#organization\",\"name\":\"Epilog Laser\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/epilog-logo.png\",\"contentUrl\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/epilog-logo.png\",\"width\":215,\"height\":46,\"caption\":\"Epilog Laser\"},\"image\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/epiloglaser\",\"https:\\\/\\\/x.com\\\/epiloglaser\",\"https:\\\/\\\/www.instagram.com\\\/epiloglaser\\\/\",\"https:\\\/\\\/www.youtube.com\\\/@epiloglaser\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/epilog\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#\\\/schema\\\/person\\\/db690367f94e26f7d0b8f3bb258d4cdd\",\"name\":\"Tyler Brock\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/author\\\/tyler\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Autofocus Switch Replacement - Pro 48 (Large Aperture) - Epilog Support Center","description":"Step-by-step guide to replacing the Autofocus Switch in a Fusion Pro 48 large aperture laser system, with images and installation details","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/service-and-repair\/autofocus-switch-replacement-pro-48-large-aperture\/","og_locale":"en_US","og_type":"article","og_title":"Autofocus Switch Replacement - Pro 48 (Large Aperture)","og_description":"Step-by-step guide to replacing the Autofocus Switch in a Fusion Pro 48 large aperture laser system, with images and installation details","og_url":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/service-and-repair\/autofocus-switch-replacement-pro-48-large-aperture\/","og_site_name":"Epilog Support Center","article_publisher":"https:\/\/www.facebook.com\/epiloglaser","article_published_time":"2025-05-30T16:04:18+00:00","article_modified_time":"2025-05-30T16:05:14+00:00","og_image":[{"width":1920,"height":1080,"url":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/fusion-pro_x-axis-tensioning-belt_01.jpg","type":"image\/jpeg"}],"author":"Tyler Brock","twitter_card":"summary_large_image","twitter_creator":"@epiloglaser","twitter_site":"@epiloglaser","twitter_misc":{"Written by":"Tyler Brock","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/service-and-repair\/autofocus-switch-replacement-pro-48-large-aperture\/#article","isPartOf":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/service-and-repair\/autofocus-switch-replacement-pro-48-large-aperture\/"},"author":{"name":"Tyler Brock","@id":"https:\/\/support.epiloglaser.com\/staging\/#\/schema\/person\/db690367f94e26f7d0b8f3bb258d4cdd"},"headline":"Autofocus Switch Replacement &#8211; Pro 48 (Large Aperture)","datePublished":"2025-05-30T16:04:18+00:00","dateModified":"2025-05-30T16:05:14+00:00","mainEntityOfPage":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/service-and-repair\/autofocus-switch-replacement-pro-48-large-aperture\/"},"wordCount":126,"publisher":{"@id":"https:\/\/support.epiloglaser.com\/staging\/#organization"},"image":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/service-and-repair\/autofocus-switch-replacement-pro-48-large-aperture\/#primaryimage"},"thumbnailUrl":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/fusion-pro_x-axis-tensioning-belt_01.jpg","articleSection":["Service and Repair","X-Axis"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/service-and-repair\/autofocus-switch-replacement-pro-48-large-aperture\/","url":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/service-and-repair\/autofocus-switch-replacement-pro-48-large-aperture\/","name":"Autofocus Switch Replacement - Pro 48 (Large Aperture) - Epilog Support Center","isPartOf":{"@id":"https:\/\/support.epiloglaser.com\/staging\/#website"},"primaryImageOfPage":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/service-and-repair\/autofocus-switch-replacement-pro-48-large-aperture\/#primaryimage"},"image":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/service-and-repair\/autofocus-switch-replacement-pro-48-large-aperture\/#primaryimage"},"thumbnailUrl":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/fusion-pro_x-axis-tensioning-belt_01.jpg","datePublished":"2025-05-30T16:04:18+00:00","dateModified":"2025-05-30T16:05:14+00:00","description":"Step-by-step guide to replacing the Autofocus Switch in a Fusion Pro 48 large aperture laser system, with images and installation details","breadcrumb":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/service-and-repair\/autofocus-switch-replacement-pro-48-large-aperture\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/service-and-repair\/autofocus-switch-replacement-pro-48-large-aperture\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/service-and-repair\/autofocus-switch-replacement-pro-48-large-aperture\/#primaryimage","url":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/fusion-pro_x-axis-tensioning-belt_01.jpg","contentUrl":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/fusion-pro_x-axis-tensioning-belt_01.jpg","width":1920,"height":1080},{"@type":"BreadcrumbList","@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/service-and-repair\/autofocus-switch-replacement-pro-48-large-aperture\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/support.epiloglaser.com\/staging\/"},{"@type":"ListItem","position":2,"name":"Autofocus Switch Replacement &#8211; Pro 48 (Large Aperture)"}]},{"@type":"WebSite","@id":"https:\/\/support.epiloglaser.com\/staging\/#website","url":"https:\/\/support.epiloglaser.com\/staging\/","name":"Epilog Support Center","description":"Imagine. Design. Create.","publisher":{"@id":"https:\/\/support.epiloglaser.com\/staging\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/support.epiloglaser.com\/staging\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/support.epiloglaser.com\/staging\/#organization","name":"Epilog Laser","url":"https:\/\/support.epiloglaser.com\/staging\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/support.epiloglaser.com\/staging\/#\/schema\/logo\/image\/","url":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/epilog-logo.png","contentUrl":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/epilog-logo.png","width":215,"height":46,"caption":"Epilog Laser"},"image":{"@id":"https:\/\/support.epiloglaser.com\/staging\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/epiloglaser","https:\/\/x.com\/epiloglaser","https:\/\/www.instagram.com\/epiloglaser\/","https:\/\/www.youtube.com\/@epiloglaser","https:\/\/www.linkedin.com\/company\/epilog"]},{"@type":"Person","@id":"https:\/\/support.epiloglaser.com\/staging\/#\/schema\/person\/db690367f94e26f7d0b8f3bb258d4cdd","name":"Tyler Brock","url":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/author\/tyler\/"}]}},"_links":{"self":[{"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/posts\/19714","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/comments?post=19714"}],"version-history":[{"count":3,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/posts\/19714\/revisions"}],"predecessor-version":[{"id":19725,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/posts\/19714\/revisions\/19725"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/media\/11750"}],"wp:attachment":[{"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/media?parent=19714"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/categories?post=19714"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/tags?post=19714"},{"taxonomy":"laser_machine","embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/laser_machine?post=19714"},{"taxonomy":"post_folder","embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/post_folder?post=19714"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}