{"id":20277,"date":"2025-07-11T14:10:28","date_gmt":"2025-07-11T20:10:28","guid":{"rendered":"https:\/\/support.epiloglaser.com\/staging\/?p=20277"},"modified":"2025-07-11T15:21:30","modified_gmt":"2025-07-11T21:21:30","slug":"applying-thermal-compound-to-large-aperture-fusion-pro-optics","status":"publish","type":"post","link":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/optics\/applying-thermal-compound-to-large-aperture-fusion-pro-optics\/","title":{"rendered":"Applying Thermal Compound to Large Aperture Fusion Pro Optics"},"content":{"rendered":"<p>\n  On the large aperture Fusion Pro systems, the optics are designed with a thermal compound applied between the mirror and its holder. Replacement mirrors include this compound pre-applied to the backside of the mirror. For routine cleaning and maintenance, additional thermal compound is not required-the existing layer remains sufficient for effective heat transfer from the mirror to the heat sink (mirror holder). However, if reapplication is necessary, follow the procedure below to ensure proper installation.\n<\/p>\n<h2 class=\"uk-heading-bullet\">Applying Thermal Compound<\/h2>\n<ol class=\"uk-list-large uk-list-decimal uk-list-divider\">\n<li>\n<p>Ensure both the mirror and the holder are clean and free of dust or debris.<\/p>\n<div class=\"uk-grid-small uk-child-width-1-2@s uk-flex-center uk-grid-match\" uk-grid>\n<div>\n<div class=\"uk-card uk-card-default uk-card-body uk-text-center\">\n      <img decoding=\"async\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/clean_mirror.jpg\" alt=\"Clean mirror\" width=\"400\"><\/p>\n<p class=\" uk-text-muted uk-margin-small-top\"> Mirror<\/p>\n<\/p><\/div>\n<\/p><\/div>\n<div>\n<div class=\"uk-card uk-card-default uk-card-body uk-text-center\">\n      <img decoding=\"async\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/clean_holder.jpg\" alt=\"Clean mirror holder\" width=\"400\"><\/p>\n<p class=\" uk-text-muted uk-margin-small-top\"> Mirror Holder<\/p>\n<\/p><\/div>\n<\/p><\/div>\n<\/div>\n<\/li>\n<li>\n<p>Apply a small dab (approximately 0.2&#8243; or 5 mm) of thermal compound to the center of the mirror\u2019s backside.<\/p>\n<p>    <img decoding=\"async\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/approx_5mm.png\" alt=\"Thermal compound applied to mirror\" class=\"uk-margin-medium-bottom uk-align-center\">\n  <\/li>\n<li>\n<p>Press the mirror firmly onto the holder and gently rotate it to spread the compound evenly between the surfaces.<\/p>\n<p>    <img decoding=\"async\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/mirror_pressure.png\" alt=\"Pressing and rotating the mirror onto the holder\" class=\"uk-margin-medium-bottom uk-align-center\">\n  <\/li>\n<li>\n<p>Ensure no excess compound is visible around the edge of the mirror. Only a thin internal layer should remain.<\/p>\n<p>    <img decoding=\"async\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/no_grease_showing.png\" alt=\"No thermal compound visible at the edge\" class=\"uk-margin-medium-bottom uk-align-center\">\n  <\/li>\n<li>\n<p>The goal is a very thin, well-distributed layer of thermal compound that stays within the bonded area and does not reach the outer edge of the mirror.<\/p>\n<p>    <img decoding=\"async\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/thin_layer.png\" alt=\"Proper thin layer of compound without spillover\" class=\"uk-margin-medium-bottom uk-align-center\">\n  <\/li>\n<\/ol>\n\r\n\t\t\t<div id=\"daexthefu-container\"\r\n\t\t\t\tclass=\"daexthefu-container daexthefu-layout-side-by-side daexthefu-alignment-left\"\r\n\t\t\t\tdata-post-id=\"20277\">\r\n\r\n\t\t\t\t<div class=\"daexthefu-feedback\">\r\n\t\t\t\t\t<div class=\"daexthefu-text\">\r\n\t\t\t\t\t\t<h3 class=\"daexthefu-title\">Was this helpful?<\/h3>\r\n\t\t\t\t\t<\/div>\r\n\t\t\t\t\t<div class=\"daexthefu-buttons-container\">\r\n\t\t\t\t\t\t<div class=\"daexthefu-buttons\">\r\n\t\t\t\t\t\t\t\r\n\t\t\t<div class=\"daexthefu-yes daexthefu-button daexthefu-button-type-text\" data-value=\"1\">\r\n\t\t\t\t<div class=\"daexthefu-button-text\">Yes<\/div>\r\n\t\t\t<\/div>\r\n\r\n\t\t\t\t\t\t\t\t\t\t\r\n\t\t\t<div class=\"daexthefu-no daexthefu-button daexthefu-button-type-text\" data-value=\"0\">\r\n\t\t\t\t<div class=\"daexthefu-button-text\">No<\/div>\r\n\t\t\t<\/div>\r\n\r\n\t\t\t\t\t\t\t\t\t<\/div>\r\n\t\t\t\t\t<\/div>\r\n\t\t\t\t<\/div>\r\n\r\n\t\t\t\t<div class=\"daexthefu-comment\">\r\n\t\t\t\t\t<div class=\"daexthefu-comment-top-container\">\r\n\t\t\t\t\t\t<label id=\"daexthefu-comment-label\" class=\"daexthefu-comment-label\"><\/label>\r\n\t\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"daexthefu-comment-character-counter-container\">\r\n\t\t\t\t\t\t\t\t<div id=\"daexthefu-comment-character-counter-number\"\r\n\t\t\t\t\t\t\t\t\tclass=\"daexthefu-comment-character-counter-number\"><\/div>\r\n\t\t\t\t\t\t\t\t<div class=\"daexthefu-comment-character-counter-text\"><\/div>\r\n\t\t\t\t\t\t\t<\/div>\r\n\t\t\t\t\t\t\t\t\t\t\t<\/div>\r\n\t\t\t\t\t<textarea id=\"daexthefu-comment-textarea\" class=\"daexthefu-comment-textarea\"\r\n\t\t\t\t\t\t\t\tplaceholder=\"Type your message\"\r\n\t\t\t\t\t\t\t\tmaxlength=\"\r\n\t\t\t\t\t\t\t\t400\t\t\t\t\t\t\t\t\t\"><\/textarea>\r\n\t\t\t\t\t<div class=\"daexthefu-comment-buttons-container\">\r\n\t\t\t\t\t\t<button class=\"daexthefu-comment-submit daexthefu-button\">Submit<\/button>\r\n\t\t\t\t\t\t<button class=\"daexthefu-comment-cancel daexthefu-button\">Cancel<\/button>\r\n\t\t\t\t\t<\/div>\r\n\t\t\t\t<\/div>\r\n\r\n\t\t\t\t<div class=\"daexthefu-successful-submission-text\">Thanks for your feedback!<\/div>\r\n\r\n\t\t\t<\/div>\r\n\r\n\t\t\t","protected":false},"excerpt":{"rendered":"<p>On the large aperture Fusion Pro systems, the optics are designed with a thermal compound applied between the mirror and its holder. Replacement mirrors include this compound pre-applied to the backside of the mirror. For routine cleaning and maintenance, additional thermal compound is not required-the existing layer remains sufficient for effective heat transfer from the [&hellip;]<\/p>\n","protected":false},"author":5,"featured_media":20289,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_helpful_status":1,"_helpful_pro_status":1,"footnotes":""},"categories":[565,557],"tags":[],"laser_machine":[65],"post_folder":[],"class_list":["post-20277","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-optics","category-service-and-repair","laser_machine-fusion-pro"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.0 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Applying Thermal Compound to Large Aperture Fusion Pro Optics - Epilog Support Center<\/title>\n<meta name=\"description\" content=\"A detailed guide for applying thermal compound to large aperture Fusion Pro optics. Improve performance and ensure proper installation.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/optics\/applying-thermal-compound-to-large-aperture-fusion-pro-optics\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Applying Thermal Compound to Large Aperture Fusion Pro Optics\" \/>\n<meta property=\"og:description\" content=\"A detailed guide for applying thermal compound to large aperture Fusion Pro optics. Improve performance and ensure proper installation.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/optics\/applying-thermal-compound-to-large-aperture-fusion-pro-optics\/\" \/>\n<meta property=\"og:site_name\" content=\"Epilog Support Center\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/epiloglaser\" \/>\n<meta property=\"article:published_time\" content=\"2025-07-11T20:10:28+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-07-11T21:21:30+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/large_aperture_mirror.png\" \/>\n\t<meta property=\"og:image:width\" content=\"350\" \/>\n\t<meta property=\"og:image:height\" content=\"197\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Tyler Brock\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@epiloglaser\" \/>\n<meta name=\"twitter:site\" content=\"@epiloglaser\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Tyler Brock\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-pro\\\/optics\\\/applying-thermal-compound-to-large-aperture-fusion-pro-optics\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-pro\\\/optics\\\/applying-thermal-compound-to-large-aperture-fusion-pro-optics\\\/\"},\"author\":{\"name\":\"Tyler Brock\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#\\\/schema\\\/person\\\/db690367f94e26f7d0b8f3bb258d4cdd\"},\"headline\":\"Applying Thermal Compound to Large Aperture Fusion Pro Optics\",\"datePublished\":\"2025-07-11T20:10:28+00:00\",\"dateModified\":\"2025-07-11T21:21:30+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-pro\\\/optics\\\/applying-thermal-compound-to-large-aperture-fusion-pro-optics\\\/\"},\"wordCount\":188,\"publisher\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-pro\\\/optics\\\/applying-thermal-compound-to-large-aperture-fusion-pro-optics\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/large_aperture_mirror.png\",\"articleSection\":[\"Optics\",\"Service and Repair\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-pro\\\/optics\\\/applying-thermal-compound-to-large-aperture-fusion-pro-optics\\\/\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-pro\\\/optics\\\/applying-thermal-compound-to-large-aperture-fusion-pro-optics\\\/\",\"name\":\"Applying Thermal Compound to Large Aperture Fusion Pro Optics - Epilog Support Center\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-pro\\\/optics\\\/applying-thermal-compound-to-large-aperture-fusion-pro-optics\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-pro\\\/optics\\\/applying-thermal-compound-to-large-aperture-fusion-pro-optics\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/large_aperture_mirror.png\",\"datePublished\":\"2025-07-11T20:10:28+00:00\",\"dateModified\":\"2025-07-11T21:21:30+00:00\",\"description\":\"A detailed guide for applying thermal compound to large aperture Fusion Pro optics. Improve performance and ensure proper installation.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-pro\\\/optics\\\/applying-thermal-compound-to-large-aperture-fusion-pro-optics\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-pro\\\/optics\\\/applying-thermal-compound-to-large-aperture-fusion-pro-optics\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-pro\\\/optics\\\/applying-thermal-compound-to-large-aperture-fusion-pro-optics\\\/#primaryimage\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/large_aperture_mirror.png\",\"contentUrl\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/large_aperture_mirror.png\",\"width\":350,\"height\":197},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-pro\\\/optics\\\/applying-thermal-compound-to-large-aperture-fusion-pro-optics\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Applying Thermal Compound to Large Aperture Fusion Pro Optics\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#website\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/\",\"name\":\"Epilog Support Center\",\"description\":\"Imagine. Design. Create.\",\"publisher\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#organization\",\"name\":\"Epilog Laser\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/epilog-logo.png\",\"contentUrl\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/epilog-logo.png\",\"width\":215,\"height\":46,\"caption\":\"Epilog Laser\"},\"image\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/epiloglaser\",\"https:\\\/\\\/x.com\\\/epiloglaser\",\"https:\\\/\\\/www.instagram.com\\\/epiloglaser\\\/\",\"https:\\\/\\\/www.youtube.com\\\/@epiloglaser\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/epilog\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#\\\/schema\\\/person\\\/db690367f94e26f7d0b8f3bb258d4cdd\",\"name\":\"Tyler Brock\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/author\\\/tyler\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Applying Thermal Compound to Large Aperture Fusion Pro Optics - Epilog Support Center","description":"A detailed guide for applying thermal compound to large aperture Fusion Pro optics. Improve performance and ensure proper installation.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/optics\/applying-thermal-compound-to-large-aperture-fusion-pro-optics\/","og_locale":"en_US","og_type":"article","og_title":"Applying Thermal Compound to Large Aperture Fusion Pro Optics","og_description":"A detailed guide for applying thermal compound to large aperture Fusion Pro optics. Improve performance and ensure proper installation.","og_url":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/optics\/applying-thermal-compound-to-large-aperture-fusion-pro-optics\/","og_site_name":"Epilog Support Center","article_publisher":"https:\/\/www.facebook.com\/epiloglaser","article_published_time":"2025-07-11T20:10:28+00:00","article_modified_time":"2025-07-11T21:21:30+00:00","og_image":[{"width":350,"height":197,"url":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/large_aperture_mirror.png","type":"image\/png"}],"author":"Tyler Brock","twitter_card":"summary_large_image","twitter_creator":"@epiloglaser","twitter_site":"@epiloglaser","twitter_misc":{"Written by":"Tyler Brock","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/optics\/applying-thermal-compound-to-large-aperture-fusion-pro-optics\/#article","isPartOf":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/optics\/applying-thermal-compound-to-large-aperture-fusion-pro-optics\/"},"author":{"name":"Tyler Brock","@id":"https:\/\/support.epiloglaser.com\/staging\/#\/schema\/person\/db690367f94e26f7d0b8f3bb258d4cdd"},"headline":"Applying Thermal Compound to Large Aperture Fusion Pro Optics","datePublished":"2025-07-11T20:10:28+00:00","dateModified":"2025-07-11T21:21:30+00:00","mainEntityOfPage":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/optics\/applying-thermal-compound-to-large-aperture-fusion-pro-optics\/"},"wordCount":188,"publisher":{"@id":"https:\/\/support.epiloglaser.com\/staging\/#organization"},"image":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/optics\/applying-thermal-compound-to-large-aperture-fusion-pro-optics\/#primaryimage"},"thumbnailUrl":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/large_aperture_mirror.png","articleSection":["Optics","Service and Repair"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/optics\/applying-thermal-compound-to-large-aperture-fusion-pro-optics\/","url":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/optics\/applying-thermal-compound-to-large-aperture-fusion-pro-optics\/","name":"Applying Thermal Compound to Large Aperture Fusion Pro Optics - Epilog Support Center","isPartOf":{"@id":"https:\/\/support.epiloglaser.com\/staging\/#website"},"primaryImageOfPage":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/optics\/applying-thermal-compound-to-large-aperture-fusion-pro-optics\/#primaryimage"},"image":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/optics\/applying-thermal-compound-to-large-aperture-fusion-pro-optics\/#primaryimage"},"thumbnailUrl":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/large_aperture_mirror.png","datePublished":"2025-07-11T20:10:28+00:00","dateModified":"2025-07-11T21:21:30+00:00","description":"A detailed guide for applying thermal compound to large aperture Fusion Pro optics. Improve performance and ensure proper installation.","breadcrumb":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/optics\/applying-thermal-compound-to-large-aperture-fusion-pro-optics\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/optics\/applying-thermal-compound-to-large-aperture-fusion-pro-optics\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/optics\/applying-thermal-compound-to-large-aperture-fusion-pro-optics\/#primaryimage","url":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/large_aperture_mirror.png","contentUrl":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/large_aperture_mirror.png","width":350,"height":197},{"@type":"BreadcrumbList","@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-pro\/optics\/applying-thermal-compound-to-large-aperture-fusion-pro-optics\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/support.epiloglaser.com\/staging\/"},{"@type":"ListItem","position":2,"name":"Applying Thermal Compound to Large Aperture Fusion Pro Optics"}]},{"@type":"WebSite","@id":"https:\/\/support.epiloglaser.com\/staging\/#website","url":"https:\/\/support.epiloglaser.com\/staging\/","name":"Epilog Support Center","description":"Imagine. Design. Create.","publisher":{"@id":"https:\/\/support.epiloglaser.com\/staging\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/support.epiloglaser.com\/staging\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/support.epiloglaser.com\/staging\/#organization","name":"Epilog Laser","url":"https:\/\/support.epiloglaser.com\/staging\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/support.epiloglaser.com\/staging\/#\/schema\/logo\/image\/","url":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/epilog-logo.png","contentUrl":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/epilog-logo.png","width":215,"height":46,"caption":"Epilog Laser"},"image":{"@id":"https:\/\/support.epiloglaser.com\/staging\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/epiloglaser","https:\/\/x.com\/epiloglaser","https:\/\/www.instagram.com\/epiloglaser\/","https:\/\/www.youtube.com\/@epiloglaser","https:\/\/www.linkedin.com\/company\/epilog"]},{"@type":"Person","@id":"https:\/\/support.epiloglaser.com\/staging\/#\/schema\/person\/db690367f94e26f7d0b8f3bb258d4cdd","name":"Tyler Brock","url":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/author\/tyler\/"}]}},"_links":{"self":[{"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/posts\/20277","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/comments?post=20277"}],"version-history":[{"count":6,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/posts\/20277\/revisions"}],"predecessor-version":[{"id":20287,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/posts\/20277\/revisions\/20287"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/media\/20289"}],"wp:attachment":[{"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/media?parent=20277"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/categories?post=20277"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/tags?post=20277"},{"taxonomy":"laser_machine","embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/laser_machine?post=20277"},{"taxonomy":"post_folder","embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/post_folder?post=20277"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}