{"id":21600,"date":"2026-04-21T16:44:41","date_gmt":"2026-04-21T22:44:41","guid":{"rendered":"https:\/\/support.epiloglaser.com\/staging\/?p=21600"},"modified":"2026-04-22T14:48:27","modified_gmt":"2026-04-22T20:48:27","slug":"air-assist-default-to-shop-air-conversion","status":"publish","type":"post","link":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/system-requirements-setup\/air-assist-default-to-shop-air-conversion\/","title":{"rendered":"Air Assist &#8211; Default to Shop Air Conversion"},"content":{"rendered":"<div class=\"uk-container uk-container-small uk-margin-medium-top uk-margin-large-bottom\">\n<div class=\"uk-card uk-card-default uk-margin-bottom\">\n<div class=\"uk-card-body\">\n<p class=\"uk-text-lead uk-margin-remove-top\">Understanding the Air Assist Solenoid<\/p>\n<p>The Ascent laser\u2019s air assist solenoid manages airflow differently depending on your compressor setup. It is critical to configure the internal tubing correctly to prevent equipment damage or excessive compressor wear.<\/p>\n<ul class=\"uk-list uk-list-divider\">\n<li><strong>Default Configuration (Constant-Run Pumps):<\/strong> Small diaphragm pumps lack a pressure shut-off switch and must run continuously. In this setup, the solenoid is plumbed to vent the air safely inside the cabinet when the laser is not actively firing. This prevents the pump from &#8220;dead-heading,&#8221; which causes overheating and motor failure.\n<div class=\"uk-text-center\">\n                                <img decoding=\"async\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/air_pump_standard.webp\" width=\"400\" alt=\"Power Switch\" class=\"uk-border-rounded\">\n                            <\/div>\n<\/li>\n<li><strong>Tank &#038; Shop Air Configuration:<\/strong> Standard air compressors feature an internal tank and a pressure switch that automatically shuts the motor off once filled. If used with the default laser tubing, the solenoid would constantly vent the tank, causing your compressor to run indefinitely. This reroute procedure switches the solenoid into a blocking configuration, holding the pressurized air at the valve until the machine triggers it for an engraving or cutting job.\n<div class=\"uk-text-center\">\n                                <img decoding=\"async\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/tank_compressor.webp\" width=\"400\" alt=\"Power Switch\" class=\"uk-border-rounded\">\n                            <\/div>\n<\/li>\n<\/ul><\/div>\n<\/p><\/div>\n<h2 class=\"uk-margin-large-top uk-margin-bottom\">Instructions for Shop Air Conversion<\/h2>\n<div class=\"uk-card uk-card-default uk-card-body uk-margin-bottom\">\n<h3 class=\"uk-card-title\">1. Disconnect Power<\/h3>\n<p>Power off the machine and completely disconnect the main power cable.<\/p>\n<div class=\"uk-grid-small uk-child-width-1-2@s uk-margin-top\" uk-grid>\n<div><img decoding=\"async\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/19k_disconnect_power-scaled.png\" alt=\"Power Switch\" class=\"uk-border-rounded\"><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"uk-card uk-card-default uk-card-body uk-margin-bottom\">\n<h3 class=\"uk-card-title\">2. Remove the Side Panel<\/h3>\n<p>Take off the right-side panel of the machine to access the solenoid.<\/p>\n<div class=\"uk-alert-warning\" uk-alert uk-border-rounded>\n<p class=\"uk-text-primary\"><strong><span uk-icon=\"icon: warning\"><\/span> High Voltage Warning:<\/strong> Do not touch any exposed power supply components.<\/p>\n<\/p><\/div>\n<div class=\"uk-grid-small uk-child-width-1-2@s uk-margin-top\" uk-grid>\n            <img decoding=\"async\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/19k_remove_right-scaled.png\" alt=\"Remove Right Panel\" class=\"uk-border-rounded\">\n        <\/div>\n<\/p><\/div>\n<div class=\"uk-card uk-card-default uk-card-body uk-margin-bottom\">\n<h3 class=\"uk-card-title\">3. Disconnect the Input Hose<\/h3>\n<p>Locate the hose running from the back of the machine to the right side of the solenoid. It is marked with a small black cable tie (and colored green in the image below). Press the collar of the push-to-connect fitting and pull the hose out.<\/p>\n<div class=\"uk-grid-small uk-child-width-1-2@s uk-margin-top\" uk-grid>\n<div><img decoding=\"async\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/19k_default_air-scaled.png\" alt=\"Locate Hose with Cable Tie\" class=\"uk-border-rounded\"><\/div>\n<figure>\n<div><img decoding=\"async\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/19k_press_to_release-scaled.png\" alt=\"Disconnect Push to Connect Fitting\" class=\"uk-border-rounded\"><\/div><figcaption class=\"uk-text-center uk-text-small uk-margin-small-top\">Air Assist Solenoid<\/figcaption><\/figure>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"uk-card uk-card-default uk-card-body uk-margin-bottom\">\n<h3 class=\"uk-card-title\">4. Disconnect the X-Axis Hose<\/h3>\n<p>Disconnect the left-side hose from the solenoid (colored in purple). This is the hose that routes up through the cable chain to the X-Axis.<\/p>\n<div class=\"uk-grid-small uk-child-width-1-2@s uk-margin-top\" uk-grid>\n            <img decoding=\"async\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/19k_right_default-scaled.png\" alt=\"Disconnect Left Hose\" class=\"uk-border-rounded\">\n        <\/div>\n<\/p><\/div>\n<div class=\"uk-card uk-card-default uk-card-body uk-margin-bottom\">\n<h3 class=\"uk-card-title\">5. Swap the Hoses<\/h3>\n<p>Reverse the configuration for shop air:<\/p>\n<ul class=\"uk-list uk-list-bullet\">\n<li>Connect the hose <strong>with the cable tie<\/strong> (running to the back) to the <strong>left<\/strong> side of the solenoid.<\/li>\n<li>Connect the hose <strong>without the cable tie<\/strong> (running to the X-Axis) to the <strong>right<\/strong> side of the solenoid.<\/li>\n<\/ul>\n<p>Simply press the hoses into the fittings to make the connections.<\/p>\n<div class=\"uk-grid-small uk-child-width-1-2@s uk-margin-top\" uk-grid>\n<div><img decoding=\"async\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/19k_shop_air-scaled.png\" alt=\"Connect Cable Tie Hose to Left\" class=\"uk-border-rounded\"><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"uk-card uk-card-default uk-card-body uk-margin-bottom\">\n<h3 class=\"uk-card-title\">6. Verification<\/h3>\n<p>Make sure all air connections are secure and routed correctly.<\/p>\n<\/p><\/div>\n<div class=\"uk-card uk-card-default uk-card-body uk-margin-bottom\">\n<h3 class=\"uk-card-title\">8. Install the Side Panel<\/h3>\n<p>Install the right-side panel of the machine.<\/p>\n<div class=\"uk-grid-small uk-child-width-1-2@s uk-margin-top\" uk-grid>\n            <img decoding=\"async\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/19k_remove_right-scaled.png\" alt=\"Remove Right Panel\" class=\"uk-border-rounded\">\n        <\/div>\n<\/p><\/div>\n<div class=\"uk-alert-success\" uk-alert uk-border-rounded>\n<p><strong>Success:<\/strong> Once you have swapped the hoses, you are now in the &#8220;Tank &#038; Shop Air Configuration&#8221;. Air should no longer vent out of the solenoid. If it does, shut down the machine and recheck the connections.<\/p>\n<\/p><\/div>\n<\/div>\n\r\n\t\t\t<div id=\"daexthefu-container\"\r\n\t\t\t\tclass=\"daexthefu-container daexthefu-layout-side-by-side daexthefu-alignment-left\"\r\n\t\t\t\tdata-post-id=\"21600\">\r\n\r\n\t\t\t\t<div class=\"daexthefu-feedback\">\r\n\t\t\t\t\t<div class=\"daexthefu-text\">\r\n\t\t\t\t\t\t<h3 class=\"daexthefu-title\">Was this helpful?<\/h3>\r\n\t\t\t\t\t<\/div>\r\n\t\t\t\t\t<div class=\"daexthefu-buttons-container\">\r\n\t\t\t\t\t\t<div class=\"daexthefu-buttons\">\r\n\t\t\t\t\t\t\t\r\n\t\t\t<div class=\"daexthefu-yes daexthefu-button daexthefu-button-type-text\" data-value=\"1\">\r\n\t\t\t\t<div class=\"daexthefu-button-text\">Yes<\/div>\r\n\t\t\t<\/div>\r\n\r\n\t\t\t\t\t\t\t\t\t\t\r\n\t\t\t<div class=\"daexthefu-no daexthefu-button daexthefu-button-type-text\" data-value=\"0\">\r\n\t\t\t\t<div class=\"daexthefu-button-text\">No<\/div>\r\n\t\t\t<\/div>\r\n\r\n\t\t\t\t\t\t\t\t\t<\/div>\r\n\t\t\t\t\t<\/div>\r\n\t\t\t\t<\/div>\r\n\r\n\t\t\t\t<div class=\"daexthefu-comment\">\r\n\t\t\t\t\t<div class=\"daexthefu-comment-top-container\">\r\n\t\t\t\t\t\t<label id=\"daexthefu-comment-label\" class=\"daexthefu-comment-label\"><\/label>\r\n\t\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"daexthefu-comment-character-counter-container\">\r\n\t\t\t\t\t\t\t\t<div id=\"daexthefu-comment-character-counter-number\"\r\n\t\t\t\t\t\t\t\t\tclass=\"daexthefu-comment-character-counter-number\"><\/div>\r\n\t\t\t\t\t\t\t\t<div class=\"daexthefu-comment-character-counter-text\"><\/div>\r\n\t\t\t\t\t\t\t<\/div>\r\n\t\t\t\t\t\t\t\t\t\t\t<\/div>\r\n\t\t\t\t\t<textarea id=\"daexthefu-comment-textarea\" class=\"daexthefu-comment-textarea\"\r\n\t\t\t\t\t\t\t\tplaceholder=\"Type your message\"\r\n\t\t\t\t\t\t\t\tmaxlength=\"\r\n\t\t\t\t\t\t\t\t400\t\t\t\t\t\t\t\t\t\"><\/textarea>\r\n\t\t\t\t\t<div class=\"daexthefu-comment-buttons-container\">\r\n\t\t\t\t\t\t<button class=\"daexthefu-comment-submit daexthefu-button\">Submit<\/button>\r\n\t\t\t\t\t\t<button class=\"daexthefu-comment-cancel daexthefu-button\">Cancel<\/button>\r\n\t\t\t\t\t<\/div>\r\n\t\t\t\t<\/div>\r\n\r\n\t\t\t\t<div class=\"daexthefu-successful-submission-text\">Thanks for your feedback!<\/div>\r\n\r\n\t\t\t<\/div>\r\n\r\n\t\t\t","protected":false},"excerpt":{"rendered":"<p>Understanding the Air Assist Solenoid The Ascent laser\u2019s air assist solenoid manages airflow differently depending on your compressor setup. It is critical to configure the internal tubing correctly to prevent equipment damage or excessive compressor wear. Default Configuration (Constant-Run Pumps): Small diaphragm pumps lack a pressure shut-off switch and must run continuously. In this setup, [&hellip;]<\/p>\n","protected":false},"author":5,"featured_media":21599,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_helpful_status":1,"_helpful_pro_status":1,"footnotes":""},"categories":[550,548],"tags":[],"laser_machine":[575],"post_folder":[],"class_list":["post-21600","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-system-requirements-setup","category-usage-and-operation","laser_machine-fusion-ascent"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.0 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Air Assist - Default to Shop Air Conversion - Epilog Support Center<\/title>\n<meta name=\"description\" content=\"Optimize your laser\u2019s air assist solenoid for any compressor setup. Ensure proper airflow and prevent equipment damage.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/system-requirements-setup\/air-assist-default-to-shop-air-conversion\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Air Assist - Default to Shop Air Conversion\" \/>\n<meta property=\"og:description\" content=\"Optimize your laser\u2019s air assist solenoid for any compressor setup. Ensure proper airflow and prevent equipment damage.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/system-requirements-setup\/air-assist-default-to-shop-air-conversion\/\" \/>\n<meta property=\"og:site_name\" content=\"Epilog Support Center\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/epiloglaser\" \/>\n<meta property=\"article:published_time\" content=\"2026-04-21T22:44:41+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-22T20:48:27+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/air_pump_standard.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"675\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"Tyler Brock\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@epiloglaser\" \/>\n<meta name=\"twitter:site\" content=\"@epiloglaser\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Tyler Brock\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-ascent\\\/system-requirements-setup\\\/air-assist-default-to-shop-air-conversion\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-ascent\\\/system-requirements-setup\\\/air-assist-default-to-shop-air-conversion\\\/\"},\"author\":{\"name\":\"Tyler Brock\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#\\\/schema\\\/person\\\/db690367f94e26f7d0b8f3bb258d4cdd\"},\"headline\":\"Air Assist &#8211; Default to Shop Air Conversion\",\"datePublished\":\"2026-04-21T22:44:41+00:00\",\"dateModified\":\"2026-04-22T20:48:27+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-ascent\\\/system-requirements-setup\\\/air-assist-default-to-shop-air-conversion\\\/\"},\"wordCount\":405,\"publisher\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-ascent\\\/system-requirements-setup\\\/air-assist-default-to-shop-air-conversion\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/air_pump_standard.webp\",\"articleSection\":[\"System Requirements &amp; Setup\",\"Usage and Operation\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-ascent\\\/system-requirements-setup\\\/air-assist-default-to-shop-air-conversion\\\/\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-ascent\\\/system-requirements-setup\\\/air-assist-default-to-shop-air-conversion\\\/\",\"name\":\"Air Assist - Default to Shop Air Conversion - Epilog Support Center\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-ascent\\\/system-requirements-setup\\\/air-assist-default-to-shop-air-conversion\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-ascent\\\/system-requirements-setup\\\/air-assist-default-to-shop-air-conversion\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/air_pump_standard.webp\",\"datePublished\":\"2026-04-21T22:44:41+00:00\",\"dateModified\":\"2026-04-22T20:48:27+00:00\",\"description\":\"Optimize your laser\u2019s air assist solenoid for any compressor setup. Ensure proper airflow and prevent equipment damage.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-ascent\\\/system-requirements-setup\\\/air-assist-default-to-shop-air-conversion\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-ascent\\\/system-requirements-setup\\\/air-assist-default-to-shop-air-conversion\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-ascent\\\/system-requirements-setup\\\/air-assist-default-to-shop-air-conversion\\\/#primaryimage\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/air_pump_standard.webp\",\"contentUrl\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/air_pump_standard.webp\",\"width\":1200,\"height\":675},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-ascent\\\/system-requirements-setup\\\/air-assist-default-to-shop-air-conversion\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Air Assist &#8211; Default to Shop Air Conversion\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#website\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/\",\"name\":\"Epilog Support Center\",\"description\":\"Imagine. Design. Create.\",\"publisher\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#organization\",\"name\":\"Epilog Laser\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/epilog-logo.png\",\"contentUrl\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/epilog-logo.png\",\"width\":215,\"height\":46,\"caption\":\"Epilog Laser\"},\"image\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/epiloglaser\",\"https:\\\/\\\/x.com\\\/epiloglaser\",\"https:\\\/\\\/www.instagram.com\\\/epiloglaser\\\/\",\"https:\\\/\\\/www.youtube.com\\\/@epiloglaser\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/epilog\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#\\\/schema\\\/person\\\/db690367f94e26f7d0b8f3bb258d4cdd\",\"name\":\"Tyler Brock\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/author\\\/tyler\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Air Assist - Default to Shop Air Conversion - Epilog Support Center","description":"Optimize your laser\u2019s air assist solenoid for any compressor setup. Ensure proper airflow and prevent equipment damage.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/system-requirements-setup\/air-assist-default-to-shop-air-conversion\/","og_locale":"en_US","og_type":"article","og_title":"Air Assist - Default to Shop Air Conversion","og_description":"Optimize your laser\u2019s air assist solenoid for any compressor setup. Ensure proper airflow and prevent equipment damage.","og_url":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/system-requirements-setup\/air-assist-default-to-shop-air-conversion\/","og_site_name":"Epilog Support Center","article_publisher":"https:\/\/www.facebook.com\/epiloglaser","article_published_time":"2026-04-21T22:44:41+00:00","article_modified_time":"2026-04-22T20:48:27+00:00","og_image":[{"width":1200,"height":675,"url":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/air_pump_standard.webp","type":"image\/webp"}],"author":"Tyler Brock","twitter_card":"summary_large_image","twitter_creator":"@epiloglaser","twitter_site":"@epiloglaser","twitter_misc":{"Written by":"Tyler Brock","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/system-requirements-setup\/air-assist-default-to-shop-air-conversion\/#article","isPartOf":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/system-requirements-setup\/air-assist-default-to-shop-air-conversion\/"},"author":{"name":"Tyler Brock","@id":"https:\/\/support.epiloglaser.com\/staging\/#\/schema\/person\/db690367f94e26f7d0b8f3bb258d4cdd"},"headline":"Air Assist &#8211; Default to Shop Air Conversion","datePublished":"2026-04-21T22:44:41+00:00","dateModified":"2026-04-22T20:48:27+00:00","mainEntityOfPage":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/system-requirements-setup\/air-assist-default-to-shop-air-conversion\/"},"wordCount":405,"publisher":{"@id":"https:\/\/support.epiloglaser.com\/staging\/#organization"},"image":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/system-requirements-setup\/air-assist-default-to-shop-air-conversion\/#primaryimage"},"thumbnailUrl":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/air_pump_standard.webp","articleSection":["System Requirements &amp; Setup","Usage and Operation"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/system-requirements-setup\/air-assist-default-to-shop-air-conversion\/","url":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/system-requirements-setup\/air-assist-default-to-shop-air-conversion\/","name":"Air Assist - Default to Shop Air Conversion - Epilog Support Center","isPartOf":{"@id":"https:\/\/support.epiloglaser.com\/staging\/#website"},"primaryImageOfPage":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/system-requirements-setup\/air-assist-default-to-shop-air-conversion\/#primaryimage"},"image":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/system-requirements-setup\/air-assist-default-to-shop-air-conversion\/#primaryimage"},"thumbnailUrl":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/air_pump_standard.webp","datePublished":"2026-04-21T22:44:41+00:00","dateModified":"2026-04-22T20:48:27+00:00","description":"Optimize your laser\u2019s air assist solenoid for any compressor setup. Ensure proper airflow and prevent equipment damage.","breadcrumb":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/system-requirements-setup\/air-assist-default-to-shop-air-conversion\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/system-requirements-setup\/air-assist-default-to-shop-air-conversion\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/system-requirements-setup\/air-assist-default-to-shop-air-conversion\/#primaryimage","url":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/air_pump_standard.webp","contentUrl":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/air_pump_standard.webp","width":1200,"height":675},{"@type":"BreadcrumbList","@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/system-requirements-setup\/air-assist-default-to-shop-air-conversion\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/support.epiloglaser.com\/staging\/"},{"@type":"ListItem","position":2,"name":"Air Assist &#8211; Default to Shop Air Conversion"}]},{"@type":"WebSite","@id":"https:\/\/support.epiloglaser.com\/staging\/#website","url":"https:\/\/support.epiloglaser.com\/staging\/","name":"Epilog Support Center","description":"Imagine. Design. Create.","publisher":{"@id":"https:\/\/support.epiloglaser.com\/staging\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/support.epiloglaser.com\/staging\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/support.epiloglaser.com\/staging\/#organization","name":"Epilog Laser","url":"https:\/\/support.epiloglaser.com\/staging\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/support.epiloglaser.com\/staging\/#\/schema\/logo\/image\/","url":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/epilog-logo.png","contentUrl":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/epilog-logo.png","width":215,"height":46,"caption":"Epilog Laser"},"image":{"@id":"https:\/\/support.epiloglaser.com\/staging\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/epiloglaser","https:\/\/x.com\/epiloglaser","https:\/\/www.instagram.com\/epiloglaser\/","https:\/\/www.youtube.com\/@epiloglaser","https:\/\/www.linkedin.com\/company\/epilog"]},{"@type":"Person","@id":"https:\/\/support.epiloglaser.com\/staging\/#\/schema\/person\/db690367f94e26f7d0b8f3bb258d4cdd","name":"Tyler Brock","url":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/author\/tyler\/"}]}},"_links":{"self":[{"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/posts\/21600","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/comments?post=21600"}],"version-history":[{"count":5,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/posts\/21600\/revisions"}],"predecessor-version":[{"id":21607,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/posts\/21600\/revisions\/21607"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/media\/21599"}],"wp:attachment":[{"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/media?parent=21600"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/categories?post=21600"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/tags?post=21600"},{"taxonomy":"laser_machine","embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/laser_machine?post=21600"},{"taxonomy":"post_folder","embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/post_folder?post=21600"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}