{"id":22111,"date":"2026-07-07T17:33:45","date_gmt":"2026-07-07T23:33:45","guid":{"rendered":"https:\/\/support.epiloglaser.com\/staging\/?p=22111"},"modified":"2026-07-07T17:38:45","modified_gmt":"2026-07-07T23:38:45","slug":"carriage-camera-calibration","status":"publish","type":"post","link":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/calibration\/carriage-camera-calibration\/","title":{"rendered":"Carriage Camera Calibration"},"content":{"rendered":"<div>\n<p>The following procedure must be performed first for all Fusion Ascent machines. Turn on the engraver, and let it complete the startup process.<\/p>\n<ol class=\"uk-list uk-list-decimal\">\n<li>On the display, press the gear icon to enter the Settings Menu.\n<div class=\"uk-padding\">\n        <img decoding=\"async\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/manual\/Settings-Menu.png\" alt=\"Settings menu\" class=\"uk-image\">\n    <\/div>\n<\/li>\n<li>Long Press the \u201cSettings\u201d text for 2-3 seconds to enter the Advanced Settings Menu.\n<div class=\"uk-padding\">\n        <img decoding=\"async\" src=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/manual\/advanced_new.png\" alt=\"Advanced settings menu\" class=\"uk-image\">\n    <\/div>\n<\/li>\n<li>Click on \u201cCalibration\u201d followed by \u201cCalibrate Cameras\u201d to enter the Camera Calibration menu. If using 1.1.2.8 or older, just tap \u201cCalibrate Cameras\u201d.\n    <\/li>\n<li>Place an 8\u201d x 5\u201d (200mm x 125mm) piece of anodized aluminum in the top left corner of the table.<\/li>\n<li>Close the top door of the engraver.<\/li>\n<li>Press OK to begin the carriage camera calibration and the engraver will move the table to the appropriate focal height for calibration.<\/li>\n<li>The engraver will mark the anodized aluminum with a pattern that the carriage camera analyzes for calibration. Once the job is complete, a success message should appear.<\/li>\n<li>Follow the on-screen prompts to continue to the overhead camera calibration.<\/li>\n<\/ol>\n<\/div>\n<p><!--more--><br \/>\n<!-- {\"type\":\"layout\",\"children\":[{\"type\":\"section\",\"props\":{\"image_position\":\"center-center\",\"style\":\"default\",\"title_breakpoint\":\"xl\",\"title_position\":\"top-left\",\"title_rotation\":\"left\",\"vertical_align\":\"middle\",\"width\":\"default\"},\"children\":[{\"type\":\"row\",\"children\":[{\"type\":\"column\",\"props\":{\"image_position\":\"center-center\",\"position_sticky_breakpoint\":\"m\"},\"children\":[{\"type\":\"html\",\"props\":{\"content\":\"\n\n<p>The following procedure must be performed first for all Fusion Ascent machines. Turn on the engraver, and let it complete the startup process.<\/p>\n\n\\n\\n\n\n<ol class=\\\"uk-list uk-list-decimal\\\">\\n    \n\n<li>On the display, press the gear icon to enter the Settings Menu.\\n    \n\n<div class=\\\"uk-padding\\\">\\n        <img src=\\\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/manual\/Settings-Menu.png\\\" alt=\\\"Settings menu\\\" class=\\\"uk-image\\\">\\n    <\/div>\n\n<\/li>\n\n\\n    \n\n<li>Long Press the \u201cSettings\u201d text for 2-3 seconds to enter the Advanced Settings Menu.\\n    \n\n<div class=\\\"uk-padding\\\">\\n        <img src=\\\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/manual\/advanced_new.png\\\" alt=\\\"Advanced settings menu\\\" class=\\\"uk-image\\\">\\n    <\/div>\n\n<\/li>\n\n\\n    \n\n<li>Click on \u201cCalibration\u201d followed by \u201cCalibrate Cameras\u201d to enter the Camera Calibration menu. If using 1.1.2.8 or older, just tap \u201cCalibrate Cameras\u201d.\\n    <\/li>\n\n\\n    \n\n<li>Place an 8\u201d x 5\u201d (200mm x 125mm) piece of anodized aluminum in the top left corner of the table.<\/li>\n\n\\n    \n\n<li>Close the top door of the engraver.<\/li>\n\n\\n    \n\n<li>Press OK to begin the carriage camera calibration and the engraver will move the table to the appropriate focal height for calibration.<\/li>\n\n\\n    \n\n<li>The engraver will mark the anodized aluminum with a pattern that the carriage camera analyzes for calibration. Once the job is complete, a success message should appear.<\/li>\n\n\\n    \n\n<li>Follow the on-screen prompts to continue to the overhead camera calibration.<\/li>\n\n\\n<\/ol>\n\n\\n\\n\"}}]}]}]}],\"version\":\"5.0.35\"} --><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The following procedure must be performed first for all Fusion Ascent machines. Turn on the engraver, and let it complete the startup process. On the display, press the gear icon to enter the Settings Menu. Long Press the \u201cSettings\u201d text for 2-3 seconds to enter the Advanced Settings Menu. Click on \u201cCalibration\u201d followed by \u201cCalibrate [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[591,578],"tags":[],"laser_machine":[575],"post_folder":[],"class_list":["post-22111","post","type-post","status-publish","format-standard","hentry","category-calibration","category-manual","laser_machine-fusion-ascent"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.0 (Yoast SEO v28.1) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Carriage Camera Calibration - Epilog Support Center<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/calibration\/carriage-camera-calibration\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Carriage Camera Calibration\" \/>\n<meta property=\"og:description\" content=\"The following procedure must be performed first for all Fusion Ascent machines. Turn on the engraver, and let it complete the startup process. On the display, press the gear icon to enter the Settings Menu. Long Press the \u201cSettings\u201d text for 2-3 seconds to enter the Advanced Settings Menu. Click on \u201cCalibration\u201d followed by \u201cCalibrate [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/calibration\/carriage-camera-calibration\/\" \/>\n<meta property=\"og:site_name\" content=\"Epilog Support Center\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/epiloglaser\" \/>\n<meta property=\"article:published_time\" content=\"2026-07-07T23:33:45+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-07T23:38:45+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/manual\/Settings-Menu.png\" \/>\n<meta name=\"author\" content=\"Billy\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@epiloglaser\" \/>\n<meta name=\"twitter:site\" content=\"@epiloglaser\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Billy\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-ascent\\\/calibration\\\/carriage-camera-calibration\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-ascent\\\/calibration\\\/carriage-camera-calibration\\\/\"},\"author\":{\"name\":\"Billy\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#\\\/schema\\\/person\\\/62709b908d1b2e3cef3756c590032c9b\"},\"headline\":\"Carriage Camera Calibration\",\"datePublished\":\"2026-07-07T23:33:45+00:00\",\"dateModified\":\"2026-07-07T23:38:45+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-ascent\\\/calibration\\\/carriage-camera-calibration\\\/\"},\"wordCount\":158,\"publisher\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-ascent\\\/calibration\\\/carriage-camera-calibration\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/manual\\\/Settings-Menu.png\",\"articleSection\":[\"Calibration\",\"Manual\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-ascent\\\/calibration\\\/carriage-camera-calibration\\\/\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-ascent\\\/calibration\\\/carriage-camera-calibration\\\/\",\"name\":\"Carriage Camera Calibration - Epilog Support Center\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-ascent\\\/calibration\\\/carriage-camera-calibration\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-ascent\\\/calibration\\\/carriage-camera-calibration\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/manual\\\/Settings-Menu.png\",\"datePublished\":\"2026-07-07T23:33:45+00:00\",\"dateModified\":\"2026-07-07T23:38:45+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-ascent\\\/calibration\\\/carriage-camera-calibration\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-ascent\\\/calibration\\\/carriage-camera-calibration\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-ascent\\\/calibration\\\/carriage-camera-calibration\\\/#primaryimage\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/manual\\\/Settings-Menu.png\",\"contentUrl\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/manual\\\/Settings-Menu.png\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-ascent\\\/calibration\\\/carriage-camera-calibration\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Carriage Camera Calibration\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#website\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/\",\"name\":\"Epilog Support Center\",\"description\":\"Imagine. Design. Create.\",\"publisher\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#organization\",\"name\":\"Epilog Laser\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/epilog-logo.png\",\"contentUrl\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/epilog-logo.png\",\"width\":215,\"height\":46,\"caption\":\"Epilog Laser\"},\"image\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/epiloglaser\",\"https:\\\/\\\/x.com\\\/epiloglaser\",\"https:\\\/\\\/www.instagram.com\\\/epiloglaser\\\/\",\"https:\\\/\\\/www.youtube.com\\\/@epiloglaser\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/epilog\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#\\\/schema\\\/person\\\/62709b908d1b2e3cef3756c590032c9b\",\"name\":\"Billy\",\"sameAs\":[\"https:\\\/\\\/support.epiloglaser.com\\\/staging\"],\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/author\\\/kbtest\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Carriage Camera Calibration - Epilog Support Center","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/calibration\/carriage-camera-calibration\/","og_locale":"en_US","og_type":"article","og_title":"Carriage Camera Calibration","og_description":"The following procedure must be performed first for all Fusion Ascent machines. Turn on the engraver, and let it complete the startup process. On the display, press the gear icon to enter the Settings Menu. Long Press the \u201cSettings\u201d text for 2-3 seconds to enter the Advanced Settings Menu. Click on \u201cCalibration\u201d followed by \u201cCalibrate [&hellip;]","og_url":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/calibration\/carriage-camera-calibration\/","og_site_name":"Epilog Support Center","article_publisher":"https:\/\/www.facebook.com\/epiloglaser","article_published_time":"2026-07-07T23:33:45+00:00","article_modified_time":"2026-07-07T23:38:45+00:00","og_image":[{"url":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/manual\/Settings-Menu.png","type":"","width":"","height":""}],"author":"Billy","twitter_card":"summary_large_image","twitter_creator":"@epiloglaser","twitter_site":"@epiloglaser","twitter_misc":{"Written by":"Billy"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/calibration\/carriage-camera-calibration\/#article","isPartOf":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/calibration\/carriage-camera-calibration\/"},"author":{"name":"Billy","@id":"https:\/\/support.epiloglaser.com\/staging\/#\/schema\/person\/62709b908d1b2e3cef3756c590032c9b"},"headline":"Carriage Camera Calibration","datePublished":"2026-07-07T23:33:45+00:00","dateModified":"2026-07-07T23:38:45+00:00","mainEntityOfPage":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/calibration\/carriage-camera-calibration\/"},"wordCount":158,"publisher":{"@id":"https:\/\/support.epiloglaser.com\/staging\/#organization"},"image":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/calibration\/carriage-camera-calibration\/#primaryimage"},"thumbnailUrl":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/manual\/Settings-Menu.png","articleSection":["Calibration","Manual"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/calibration\/carriage-camera-calibration\/","url":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/calibration\/carriage-camera-calibration\/","name":"Carriage Camera Calibration - Epilog Support Center","isPartOf":{"@id":"https:\/\/support.epiloglaser.com\/staging\/#website"},"primaryImageOfPage":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/calibration\/carriage-camera-calibration\/#primaryimage"},"image":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/calibration\/carriage-camera-calibration\/#primaryimage"},"thumbnailUrl":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/manual\/Settings-Menu.png","datePublished":"2026-07-07T23:33:45+00:00","dateModified":"2026-07-07T23:38:45+00:00","breadcrumb":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/calibration\/carriage-camera-calibration\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/calibration\/carriage-camera-calibration\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/calibration\/carriage-camera-calibration\/#primaryimage","url":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/manual\/Settings-Menu.png","contentUrl":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/manual\/Settings-Menu.png"},{"@type":"BreadcrumbList","@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/calibration\/carriage-camera-calibration\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/support.epiloglaser.com\/staging\/"},{"@type":"ListItem","position":2,"name":"Carriage Camera Calibration"}]},{"@type":"WebSite","@id":"https:\/\/support.epiloglaser.com\/staging\/#website","url":"https:\/\/support.epiloglaser.com\/staging\/","name":"Epilog Support Center","description":"Imagine. Design. Create.","publisher":{"@id":"https:\/\/support.epiloglaser.com\/staging\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/support.epiloglaser.com\/staging\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/support.epiloglaser.com\/staging\/#organization","name":"Epilog Laser","url":"https:\/\/support.epiloglaser.com\/staging\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/support.epiloglaser.com\/staging\/#\/schema\/logo\/image\/","url":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/epilog-logo.png","contentUrl":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/epilog-logo.png","width":215,"height":46,"caption":"Epilog Laser"},"image":{"@id":"https:\/\/support.epiloglaser.com\/staging\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/epiloglaser","https:\/\/x.com\/epiloglaser","https:\/\/www.instagram.com\/epiloglaser\/","https:\/\/www.youtube.com\/@epiloglaser","https:\/\/www.linkedin.com\/company\/epilog"]},{"@type":"Person","@id":"https:\/\/support.epiloglaser.com\/staging\/#\/schema\/person\/62709b908d1b2e3cef3756c590032c9b","name":"Billy","sameAs":["https:\/\/support.epiloglaser.com\/staging"],"url":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/author\/kbtest\/"}]}},"_links":{"self":[{"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/posts\/22111","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/comments?post=22111"}],"version-history":[{"count":2,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/posts\/22111\/revisions"}],"predecessor-version":[{"id":22113,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/posts\/22111\/revisions\/22113"}],"wp:attachment":[{"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/media?parent=22111"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/categories?post=22111"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/tags?post=22111"},{"taxonomy":"laser_machine","embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/laser_machine?post=22111"},{"taxonomy":"post_folder","embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/post_folder?post=22111"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}