{"id":22114,"date":"2026-07-07T17:39:39","date_gmt":"2026-07-07T23:39:39","guid":{"rendered":"https:\/\/support.epiloglaser.com\/staging\/?p=22114"},"modified":"2026-07-07T17:40:57","modified_gmt":"2026-07-07T23:40:57","slug":"overhead-camera-calibration","status":"publish","type":"post","link":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/calibration\/overhead-camera-calibration\/","title":{"rendered":"Overhead Camera Calibration"},"content":{"rendered":"<div>\n<ol class=\"uk-list uk-list-decimal uk-list-large\">\n<li>Install Mat: Place calibration mat in the upper-left corner of the table. Ensure the green circle is in the corner.<\/li>\n<li>Run: Close doors and press OK.<\/li>\n<li>Follow the prompt and close the top door of the engraver.<\/li>\n<li>Allow the process to run until completion. The camera at the laser head will take pictures of the mat to calibrate itself. This process takes several minutes.<\/li>\n<li>Once the calibration has successfully finished, a dialog will appear. The \u201cReprojection error\u201d will be listed and is used to determine the quality of the calibration. The lower the value, the better. A value of 0.6 or lower is desired. If the reprojection error is above 2.0, the user will see an error \u201cCalibration unsuccessful. Error too high\u201d.<\/li>\n<\/ol>\n<\/div>\n<p><!--more--><br \/>\n<!-- {\"type\":\"layout\",\"children\":[{\"type\":\"section\",\"props\":{\"image_position\":\"center-center\",\"style\":\"default\",\"title_breakpoint\":\"xl\",\"title_position\":\"top-left\",\"title_rotation\":\"left\",\"vertical_align\":\"middle\",\"width\":\"default\"},\"children\":[{\"type\":\"row\",\"children\":[{\"type\":\"column\",\"props\":{\"image_position\":\"center-center\",\"position_sticky_breakpoint\":\"m\"},\"children\":[{\"type\":\"html\",\"props\":{\"content\":\"\n\n<ol class=\\\"uk-list uk-list-decimal uk-list-large\\\">\\n    \n\n<li>Install Mat: Place calibration mat in the upper-left corner of the table. Ensure the green circle is in the corner.<\/li>\n\n\\n    \n\n<li>Run: Close doors and press OK.<\/li>\n\n\\n    \n\n<li>Follow the prompt and close the top door of the engraver.<\/li>\n\n\\n    \n\n<li>Allow the process to run until completion. The camera at the laser head will take pictures of the mat to calibrate itself. This process takes several minutes.<\/li>\n\n\\n    \n\n<li>Once the calibration has successfully finished, a dialog will appear. The \u201cReprojection error\u201d will be listed and is used to determine the quality of the calibration. The lower the value, the better. A value of 0.6 or lower is desired. If the reprojection error is above 2.0, the user will see an error \u201cCalibration unsuccessful. Error too high\u201d.<\/li>\n\n\\n<\/ol>\n\n\"}}]}]}]}],\"version\":\"5.0.35\"} --><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Install Mat: Place calibration mat in the upper-left corner of the table. Ensure the green circle is in the corner. Run: Close doors and press OK. Follow the prompt and close the top door of the engraver. Allow the process to run until completion. The camera at the laser head will take pictures of the [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[591,578],"tags":[],"laser_machine":[575],"post_folder":[],"class_list":["post-22114","post","type-post","status-publish","format-standard","hentry","category-calibration","category-manual","laser_machine-fusion-ascent"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.0 (Yoast SEO v28.1) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Overhead Camera Calibration - Epilog Support Center<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/calibration\/overhead-camera-calibration\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Overhead Camera Calibration\" \/>\n<meta property=\"og:description\" content=\"Install Mat: Place calibration mat in the upper-left corner of the table. Ensure the green circle is in the corner. Run: Close doors and press OK. Follow the prompt and close the top door of the engraver. Allow the process to run until completion. The camera at the laser head will take pictures of the [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/calibration\/overhead-camera-calibration\/\" \/>\n<meta property=\"og:site_name\" content=\"Epilog Support Center\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/epiloglaser\" \/>\n<meta property=\"article:published_time\" content=\"2026-07-07T23:39:39+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-07T23:40:57+00:00\" \/>\n<meta name=\"author\" content=\"Billy\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@epiloglaser\" \/>\n<meta name=\"twitter:site\" content=\"@epiloglaser\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Billy\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-ascent\\\/calibration\\\/overhead-camera-calibration\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-ascent\\\/calibration\\\/overhead-camera-calibration\\\/\"},\"author\":{\"name\":\"Billy\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#\\\/schema\\\/person\\\/62709b908d1b2e3cef3756c590032c9b\"},\"headline\":\"Overhead Camera Calibration\",\"datePublished\":\"2026-07-07T23:39:39+00:00\",\"dateModified\":\"2026-07-07T23:40:57+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-ascent\\\/calibration\\\/overhead-camera-calibration\\\/\"},\"wordCount\":123,\"publisher\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#organization\"},\"articleSection\":[\"Calibration\",\"Manual\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-ascent\\\/calibration\\\/overhead-camera-calibration\\\/\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-ascent\\\/calibration\\\/overhead-camera-calibration\\\/\",\"name\":\"Overhead Camera Calibration - Epilog Support Center\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#website\"},\"datePublished\":\"2026-07-07T23:39:39+00:00\",\"dateModified\":\"2026-07-07T23:40:57+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-ascent\\\/calibration\\\/overhead-camera-calibration\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-ascent\\\/calibration\\\/overhead-camera-calibration\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-ascent\\\/calibration\\\/overhead-camera-calibration\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Overhead Camera Calibration\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#website\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/\",\"name\":\"Epilog Support Center\",\"description\":\"Imagine. Design. Create.\",\"publisher\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#organization\",\"name\":\"Epilog Laser\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/epilog-logo.png\",\"contentUrl\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/epilog-logo.png\",\"width\":215,\"height\":46,\"caption\":\"Epilog Laser\"},\"image\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/epiloglaser\",\"https:\\\/\\\/x.com\\\/epiloglaser\",\"https:\\\/\\\/www.instagram.com\\\/epiloglaser\\\/\",\"https:\\\/\\\/www.youtube.com\\\/@epiloglaser\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/epilog\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#\\\/schema\\\/person\\\/62709b908d1b2e3cef3756c590032c9b\",\"name\":\"Billy\",\"sameAs\":[\"https:\\\/\\\/support.epiloglaser.com\\\/staging\"],\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/author\\\/kbtest\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Overhead Camera Calibration - Epilog Support Center","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/calibration\/overhead-camera-calibration\/","og_locale":"en_US","og_type":"article","og_title":"Overhead Camera Calibration","og_description":"Install Mat: Place calibration mat in the upper-left corner of the table. Ensure the green circle is in the corner. Run: Close doors and press OK. Follow the prompt and close the top door of the engraver. Allow the process to run until completion. The camera at the laser head will take pictures of the [&hellip;]","og_url":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/calibration\/overhead-camera-calibration\/","og_site_name":"Epilog Support Center","article_publisher":"https:\/\/www.facebook.com\/epiloglaser","article_published_time":"2026-07-07T23:39:39+00:00","article_modified_time":"2026-07-07T23:40:57+00:00","author":"Billy","twitter_card":"summary_large_image","twitter_creator":"@epiloglaser","twitter_site":"@epiloglaser","twitter_misc":{"Written by":"Billy"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/calibration\/overhead-camera-calibration\/#article","isPartOf":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/calibration\/overhead-camera-calibration\/"},"author":{"name":"Billy","@id":"https:\/\/support.epiloglaser.com\/staging\/#\/schema\/person\/62709b908d1b2e3cef3756c590032c9b"},"headline":"Overhead Camera Calibration","datePublished":"2026-07-07T23:39:39+00:00","dateModified":"2026-07-07T23:40:57+00:00","mainEntityOfPage":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/calibration\/overhead-camera-calibration\/"},"wordCount":123,"publisher":{"@id":"https:\/\/support.epiloglaser.com\/staging\/#organization"},"articleSection":["Calibration","Manual"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/calibration\/overhead-camera-calibration\/","url":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/calibration\/overhead-camera-calibration\/","name":"Overhead Camera Calibration - Epilog Support Center","isPartOf":{"@id":"https:\/\/support.epiloglaser.com\/staging\/#website"},"datePublished":"2026-07-07T23:39:39+00:00","dateModified":"2026-07-07T23:40:57+00:00","breadcrumb":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/calibration\/overhead-camera-calibration\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/calibration\/overhead-camera-calibration\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/calibration\/overhead-camera-calibration\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/support.epiloglaser.com\/staging\/"},{"@type":"ListItem","position":2,"name":"Overhead Camera Calibration"}]},{"@type":"WebSite","@id":"https:\/\/support.epiloglaser.com\/staging\/#website","url":"https:\/\/support.epiloglaser.com\/staging\/","name":"Epilog Support Center","description":"Imagine. Design. Create.","publisher":{"@id":"https:\/\/support.epiloglaser.com\/staging\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/support.epiloglaser.com\/staging\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/support.epiloglaser.com\/staging\/#organization","name":"Epilog Laser","url":"https:\/\/support.epiloglaser.com\/staging\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/support.epiloglaser.com\/staging\/#\/schema\/logo\/image\/","url":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/epilog-logo.png","contentUrl":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/epilog-logo.png","width":215,"height":46,"caption":"Epilog Laser"},"image":{"@id":"https:\/\/support.epiloglaser.com\/staging\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/epiloglaser","https:\/\/x.com\/epiloglaser","https:\/\/www.instagram.com\/epiloglaser\/","https:\/\/www.youtube.com\/@epiloglaser","https:\/\/www.linkedin.com\/company\/epilog"]},{"@type":"Person","@id":"https:\/\/support.epiloglaser.com\/staging\/#\/schema\/person\/62709b908d1b2e3cef3756c590032c9b","name":"Billy","sameAs":["https:\/\/support.epiloglaser.com\/staging"],"url":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/author\/kbtest\/"}]}},"_links":{"self":[{"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/posts\/22114","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/comments?post=22114"}],"version-history":[{"count":2,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/posts\/22114\/revisions"}],"predecessor-version":[{"id":22116,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/posts\/22114\/revisions\/22116"}],"wp:attachment":[{"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/media?parent=22114"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/categories?post=22114"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/tags?post=22114"},{"taxonomy":"laser_machine","embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/laser_machine?post=22114"},{"taxonomy":"post_folder","embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/post_folder?post=22114"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}