{"id":22117,"date":"2026-07-07T17:41:42","date_gmt":"2026-07-07T23:41:42","guid":{"rendered":"https:\/\/support.epiloglaser.com\/staging\/?p=22117"},"modified":"2026-07-08T16:26:19","modified_gmt":"2026-07-08T22:26:19","slug":"machine-settings","status":"publish","type":"post","link":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/calibration\/machine-settings\/","title":{"rendered":"Machine Settings"},"content":{"rendered":"<div>\n<h4>Key Machine Settings<\/h4>\n<ul class=\"uk-list uk-list-disc\">\n<li><strong>Acceleration Match Offset [cnts]:<\/strong> Number of encoder counts to delay firing laser when accelerating. Used for raster quality adjustments.<\/li>\n<li><strong>Deceleration Match Offset [cnts]:<\/strong> Number of encoder counts to delay firing laser when decelerating. Used for raster quality adjustments.<\/li>\n<li><strong>Bed Margins [in]:<\/strong> The margins around the bed, in inches that the carriage can travel to. Format is: TOP,LEFT,BOTTOM,RIGHT.<\/li>\n<li><strong>Bed Size [in]:<\/strong> The size of the bed in the machine in inches. Format is: WIDTH,HEIGHT. Requires \u201cHome Axis\u201d to take effect.<\/li>\n<li><strong>Disable Table Homing:<\/strong> Setting to disable homing the table when the machine boots. For optimal operation, leave this at a value of 0. A value of 1 will disable table homing. Will take effect after reboot.<\/li>\n<li><strong>Rotary Encoder [cnts\/in]:<\/strong> The number of encoder counts per inch of travel for the rotary device. Requires \u201cHome Axis\u201d to take effect.<\/li>\n<li><strong>X Axis Encoder [cnts\/in]:<\/strong> The number of encoder counter per inch of travel for the X Axis. Requires \u201cHome Axis\u201d to take effect. Must recalibrate cameras if this changes.<\/li>\n<li><strong>Y Axis Encoder [cnts\/in]:<\/strong> The number of encoder counter per inch of travel for the Y Axis. Requires \u201cHome Axis\u201d to take effect. Must recalibrate cameras if this changes.<\/li>\n<li><strong>Home Offset [in]:<\/strong> The offset of the table origin, relative to the X and Y limit switches. Requires \u201cPark Axis\u201d to take effect. Must recalibrate cameras if this changes.<\/li>\n<li><strong>Joystick Center X:<\/strong> The center X position of the joystick, in joystick units.<\/li>\n<li><strong>Joystick Center Y:<\/strong> The center Y position of the joystick, in joystick units.<\/li>\n<li><strong>Joystick Deadzone [%\/100]:<\/strong> The percentage of dead zone around the center of the joystick.<\/li>\n<li><strong>Joystick Limit X:<\/strong> The MIN and MAX limits for the X axis of the joystick, in joystick units. Format is: MIN,MAX.<\/li>\n<li><strong>Joystick Limit Y:<\/strong> The MIN and MAX limits for the Y axis of the joystick, in joystick units. Format is: MIN,MAX.<\/li>\n<li><strong>Laser Match [cnts]:<\/strong> Adjustment to synchronize left to right and right to left raster lines. Units are in number of encoder counts.<\/li>\n<li><strong>Laser Match Offset [cnts]:<\/strong> Offset of the raster data in X. Used to align raster and vector if needed. Units are in number of encoder counts.<\/li>\n<li><strong>Velocity Match Offset [cnts]:<\/strong> Offset of the raster data proportional to velocity. Units are in number of encoder counts.<\/li>\n<li><strong>Park Position [in]:<\/strong> The position in inches to park the laser head when the machine is idle. Requires \u201cPark Axis\u201d to take effect.<\/li>\n<li><strong>Plunger Offset [cnts]:<\/strong> The distance in table encoder counts from the laser zero focus position, to the auto focus plunger.<\/li>\n<li><strong>Rotary Offset [in]:<\/strong> The offset of the rotary origin, relative to the X and Y limit switches.<\/li>\n<li><strong>Rotary Table Height [in]:<\/strong> The distance in inches to clear the rotary device.<\/li>\n<li><strong>Scale [mm\/in]:<\/strong> A scale factor to adjust the scale of the X and Y axis. Format is: X,Y. Requires \u201cHome Axis\u201d to take effect. Must recalibrate cameras if this changes.<\/li>\n<li><strong>Table Switch Locations [cnts]:<\/strong> A list of the locations in which the table switches were located.<\/li>\n<li><strong>Table Current [A]:<\/strong> The current in Amps to run the table drive.<\/li>\n<li><strong>Table Resolution [cnts\/in]:<\/strong> The number of encoder counts per inch of travel for the table. Must \u201cHome Table\u201d if this value is changed.<\/li>\n<li><strong>CO2 Tickle Duration [us]:<\/strong> The duration of the laser tickle pulse in microseconds.<\/li>\n<li><strong>CO2 Tickle Frequency [Hz]:<\/strong> The frequency of the laser tickle pulse in hertz.<\/li>\n<li><strong>CO2 Tickle Holdoff [us]:<\/strong> The duration in which the laser tickle is stalled after a laser pulse in microseconds.<\/li>\n<li><strong>CO2 Pulse Stretch [us]:<\/strong> The amount to stretch all laser pulses in microseconds.<\/li>\n<li><strong>Table Focus Offset [cnts]:<\/strong> The distance in table encoder counts from the top crash switch, to the laser focus position.<\/li>\n<li><strong>RHS Y Skew [cnts]:<\/strong> The number of encoder counts to skew the right hand side of the Y axis after homing. Requires \u201cHome Axis\u201d to take effect.<\/li>\n<li><strong>Air Assist Delay [s]:<\/strong> The number of seconds to delay turning ON and turning OFF the air assist before and after a job finished. Format is: ON,OFF.<\/li>\n<\/ul>\n<\/div>\n<p><!--more--><br \/>\n<!-- {\"type\":\"layout\",\"children\":[{\"type\":\"section\",\"props\":{\"image_position\":\"center-center\",\"style\":\"default\",\"title_breakpoint\":\"xl\",\"title_position\":\"top-left\",\"title_rotation\":\"left\",\"vertical_align\":\"middle\",\"width\":\"default\"},\"children\":[{\"type\":\"row\",\"children\":[{\"type\":\"column\",\"props\":{\"image_position\":\"center-center\",\"position_sticky_breakpoint\":\"m\"},\"children\":[{\"type\":\"html\",\"props\":{\"content\":\"\n\n<h4>Key Machine Settings<\/h4>\n\n\\n\n\n<ul class=\\\"uk-list uk-list-disc\\\">\\n    \n\n<li><strong>Acceleration Match Offset [cnts]:<\/strong> Number of encoder counts to delay firing laser when accelerating. Used for raster quality adjustments.<\/li>\n\n\\n    \n\n<li><strong>Deceleration Match Offset [cnts]:<\/strong> Number of encoder counts to delay firing laser when decelerating. Used for raster quality adjustments.<\/li>\n\n\\n    \n\n<li><strong>Bed Margins [in]:<\/strong> The margins around the bed, in inches that the carriage can travel to. Format is: TOP,LEFT,BOTTOM,RIGHT.<\/li>\n\n\\n    \n\n<li><strong>Bed Size [in]:<\/strong> The size of the bed in the machine in inches. Format is: WIDTH,HEIGHT. Requires \u201cHome Axis\u201d to take effect.<\/li>\n\n\\n    \n\n<li><strong>Disable Table Homing:<\/strong> Setting to disable homing the table when the machine boots. For optimal operation, leave this at a value of 0. A value of 1 will disable table homing. Will take effect after reboot.<\/li>\n\n\\n    \n\n<li><strong>Rotary Encoder [cnts\/in]:<\/strong> The number of encoder counts per inch of travel for the rotary device. Requires \u201cHome Axis\u201d to take effect.<\/li>\n\n\\n    \n\n<li><strong>X Axis Encoder [cnts\/in]:<\/strong> The number of encoder counter per inch of travel for the X Axis. Requires \u201cHome Axis\u201d to take effect. Must recalibrate cameras if this changes.<\/li>\n\n\\n    \n\n<li><strong>Y Axis Encoder [cnts\/in]:<\/strong> The number of encoder counter per inch of travel for the Y Axis. Requires \u201cHome Axis\u201d to take effect. Must recalibrate cameras if this changes.<\/li>\n\n\\n    \n\n<li><strong>Home Offset [in]:<\/strong> The offset of the table origin, relative to the X and Y limit switches. Requires \u201cPark Axis\u201d to take effect. Must recalibrate cameras if this changes.<\/li>\n\n\\n    \n\n<li><strong>Joystick Center X:<\/strong> The center X position of the joystick, in joystick units.<\/li>\n\n\\n    \n\n<li><strong>Joystick Center Y:<\/strong> The center Y position of the joystick, in joystick units.<\/li>\n\n\\n    \n\n<li><strong>Joystick Deadzone [%\/100]:<\/strong> The percentage of dead zone around the center of the joystick.<\/li>\n\n\\n    \n\n<li><strong>Joystick Limit X:<\/strong> The MIN and MAX limits for the X axis of the joystick, in joystick units. Format is: MIN,MAX.<\/li>\n\n\\n    \n\n<li><strong>Joystick Limit Y:<\/strong> The MIN and MAX limits for the Y axis of the joystick, in joystick units. Format is: MIN,MAX.<\/li>\n\n\\n    \n\n<li><strong>Laser Match [cnts]:<\/strong> Adjustment to synchronize left to right and right to left raster lines. Units are in number of encoder counts.<\/li>\n\n\\n    \n\n<li><strong>Laser Match Offset [cnts]:<\/strong> Offset of the raster data in X. Used to align raster and vector if needed. Units are in number of encoder counts.<\/li>\n\n\\n    \n\n<li><strong>Velocity Match Offset [cnts]:<\/strong> Offset of the raster data proportional to velocity. Units are in number of encoder counts.<\/li>\n\n\\n    \n\n<li><strong>Park Position [in]:<\/strong> The position in inches to park the laser head when the machine is idle. Requires \u201cPark Axis\u201d to take effect.<\/li>\n\n\\n    \n\n<li><strong>Plunger Offset [cnts]:<\/strong> The distance in table encoder counts from the laser zero focus position, to the auto focus plunger.<\/li>\n\n\\n    \n\n<li><strong>Rotary Offset [in]:<\/strong> The offset of the rotary origin, relative to the X and Y limit switches.<\/li>\n\n\\n    \n\n<li><strong>Rotary Table Height [in]:<\/strong> The distance in inches to clear the rotary device.<\/li>\n\n\\n    \n\n<li><strong>Scale [mm\/in]:<\/strong> A scale factor to adjust the scale of the X and Y axis. Format is: X,Y. Requires \u201cHome Axis\u201d to take effect. Must recalibrate cameras if this changes.<\/li>\n\n\\n    \n\n<li><strong>Table Switch Locations [cnts]:<\/strong> A list of the locations in which the table switches were located.<\/li>\n\n\\n    \n\n<li><strong>Table Current [A]:<\/strong> The current in Amps to run the table drive.<\/li>\n\n\\n    \n\n<li><strong>Table Resolution [cnts\/in]:<\/strong> The number of encoder counts per inch of travel for the table. Must \u201cHome Table\u201d if this value is changed.<\/li>\n\n\\n    \n\n<li><strong>CO2 Tickle Duration [us]:<\/strong> The duration of the laser tickle pulse in microseconds.<\/li>\n\n\\n    \n\n<li><strong>CO2 Tickle Frequency [Hz]:<\/strong> The frequency of the laser tickle pulse in hertz.<\/li>\n\n\\n    \n\n<li><strong>CO2 Tickle Holdoff [us]:<\/strong> The duration in which the laser tickle is stalled after a laser pulse in microseconds.<\/li>\n\n\\n    \n\n<li><strong>CO2 Pulse Stretch [us]:<\/strong> The amount to stretch all laser pulses in microseconds.<\/li>\n\n\\n    \n\n<li><strong>Table Focus Offset [cnts]:<\/strong> The distance in table encoder counts from the top crash switch, to the laser focus position.<\/li>\n\n\\n    \n\n<li><strong>RHS Y Skew [cnts]:<\/strong> The number of encoder counts to skew the right hand side of the Y axis after homing. Requires \u201cHome Axis\u201d to take effect.<\/li>\n\n\\n    \n\n<li><strong>Air Assist Delay [s]:<\/strong> The number of seconds to delay turning ON and turning OFF the air assist before and after a job finished. Format is: ON,OFF.<\/li>\n\n\\n<\/ul>\n\n\"}}]}]}]}],\"version\":\"5.0.35\"} --><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Key Machine Settings Acceleration Match Offset [cnts]: Number of encoder counts to delay firing laser when accelerating. Used for raster quality adjustments. Deceleration Match Offset [cnts]: Number of encoder counts to delay firing laser when decelerating. Used for raster quality adjustments. Bed Margins [in]: The margins around the bed, in inches that the carriage can [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[591,578],"tags":[],"laser_machine":[575],"post_folder":[],"class_list":["post-22117","post","type-post","status-publish","format-standard","hentry","category-calibration","category-manual","laser_machine-fusion-ascent"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.0 (Yoast SEO v28.1) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Machine Settings - Epilog Support Center<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/calibration\/machine-settings\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Machine Settings\" \/>\n<meta property=\"og:description\" content=\"Key Machine Settings Acceleration Match Offset [cnts]: Number of encoder counts to delay firing laser when accelerating. Used for raster quality adjustments. Deceleration Match Offset [cnts]: Number of encoder counts to delay firing laser when decelerating. Used for raster quality adjustments. Bed Margins [in]: The margins around the bed, in inches that the carriage can [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/calibration\/machine-settings\/\" \/>\n<meta property=\"og:site_name\" content=\"Epilog Support Center\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/epiloglaser\" \/>\n<meta property=\"article:published_time\" content=\"2026-07-07T23:41:42+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-08T22:26:19+00:00\" \/>\n<meta name=\"author\" content=\"Billy\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@epiloglaser\" \/>\n<meta name=\"twitter:site\" content=\"@epiloglaser\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Billy\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-ascent\\\/calibration\\\/machine-settings\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-ascent\\\/calibration\\\/machine-settings\\\/\"},\"author\":{\"name\":\"Billy\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#\\\/schema\\\/person\\\/62709b908d1b2e3cef3756c590032c9b\"},\"headline\":\"Machine Settings\",\"datePublished\":\"2026-07-07T23:41:42+00:00\",\"dateModified\":\"2026-07-08T22:26:19+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-ascent\\\/calibration\\\/machine-settings\\\/\"},\"wordCount\":674,\"publisher\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#organization\"},\"articleSection\":[\"Calibration\",\"Manual\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-ascent\\\/calibration\\\/machine-settings\\\/\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-ascent\\\/calibration\\\/machine-settings\\\/\",\"name\":\"Machine Settings - Epilog Support Center\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#website\"},\"datePublished\":\"2026-07-07T23:41:42+00:00\",\"dateModified\":\"2026-07-08T22:26:19+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-ascent\\\/calibration\\\/machine-settings\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-ascent\\\/calibration\\\/machine-settings\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/fusion-ascent\\\/calibration\\\/machine-settings\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Machine Settings\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#website\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/\",\"name\":\"Epilog Support Center\",\"description\":\"Imagine. Design. Create.\",\"publisher\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#organization\",\"name\":\"Epilog Laser\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/epilog-logo.png\",\"contentUrl\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/wp-content\\\/uploads\\\/epilog-logo.png\",\"width\":215,\"height\":46,\"caption\":\"Epilog Laser\"},\"image\":{\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/epiloglaser\",\"https:\\\/\\\/x.com\\\/epiloglaser\",\"https:\\\/\\\/www.instagram.com\\\/epiloglaser\\\/\",\"https:\\\/\\\/www.youtube.com\\\/@epiloglaser\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/epilog\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/#\\\/schema\\\/person\\\/62709b908d1b2e3cef3756c590032c9b\",\"name\":\"Billy\",\"sameAs\":[\"https:\\\/\\\/support.epiloglaser.com\\\/staging\"],\"url\":\"https:\\\/\\\/support.epiloglaser.com\\\/staging\\\/laser-machine\\\/author\\\/kbtest\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Machine Settings - Epilog Support Center","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/calibration\/machine-settings\/","og_locale":"en_US","og_type":"article","og_title":"Machine Settings","og_description":"Key Machine Settings Acceleration Match Offset [cnts]: Number of encoder counts to delay firing laser when accelerating. Used for raster quality adjustments. Deceleration Match Offset [cnts]: Number of encoder counts to delay firing laser when decelerating. Used for raster quality adjustments. Bed Margins [in]: The margins around the bed, in inches that the carriage can [&hellip;]","og_url":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/calibration\/machine-settings\/","og_site_name":"Epilog Support Center","article_publisher":"https:\/\/www.facebook.com\/epiloglaser","article_published_time":"2026-07-07T23:41:42+00:00","article_modified_time":"2026-07-08T22:26:19+00:00","author":"Billy","twitter_card":"summary_large_image","twitter_creator":"@epiloglaser","twitter_site":"@epiloglaser","twitter_misc":{"Written by":"Billy"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/calibration\/machine-settings\/#article","isPartOf":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/calibration\/machine-settings\/"},"author":{"name":"Billy","@id":"https:\/\/support.epiloglaser.com\/staging\/#\/schema\/person\/62709b908d1b2e3cef3756c590032c9b"},"headline":"Machine Settings","datePublished":"2026-07-07T23:41:42+00:00","dateModified":"2026-07-08T22:26:19+00:00","mainEntityOfPage":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/calibration\/machine-settings\/"},"wordCount":674,"publisher":{"@id":"https:\/\/support.epiloglaser.com\/staging\/#organization"},"articleSection":["Calibration","Manual"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/calibration\/machine-settings\/","url":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/calibration\/machine-settings\/","name":"Machine Settings - Epilog Support Center","isPartOf":{"@id":"https:\/\/support.epiloglaser.com\/staging\/#website"},"datePublished":"2026-07-07T23:41:42+00:00","dateModified":"2026-07-08T22:26:19+00:00","breadcrumb":{"@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/calibration\/machine-settings\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/calibration\/machine-settings\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/fusion-ascent\/calibration\/machine-settings\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/support.epiloglaser.com\/staging\/"},{"@type":"ListItem","position":2,"name":"Machine Settings"}]},{"@type":"WebSite","@id":"https:\/\/support.epiloglaser.com\/staging\/#website","url":"https:\/\/support.epiloglaser.com\/staging\/","name":"Epilog Support Center","description":"Imagine. Design. Create.","publisher":{"@id":"https:\/\/support.epiloglaser.com\/staging\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/support.epiloglaser.com\/staging\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/support.epiloglaser.com\/staging\/#organization","name":"Epilog Laser","url":"https:\/\/support.epiloglaser.com\/staging\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/support.epiloglaser.com\/staging\/#\/schema\/logo\/image\/","url":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/epilog-logo.png","contentUrl":"https:\/\/support.epiloglaser.com\/staging\/wp-content\/uploads\/epilog-logo.png","width":215,"height":46,"caption":"Epilog Laser"},"image":{"@id":"https:\/\/support.epiloglaser.com\/staging\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/epiloglaser","https:\/\/x.com\/epiloglaser","https:\/\/www.instagram.com\/epiloglaser\/","https:\/\/www.youtube.com\/@epiloglaser","https:\/\/www.linkedin.com\/company\/epilog"]},{"@type":"Person","@id":"https:\/\/support.epiloglaser.com\/staging\/#\/schema\/person\/62709b908d1b2e3cef3756c590032c9b","name":"Billy","sameAs":["https:\/\/support.epiloglaser.com\/staging"],"url":"https:\/\/support.epiloglaser.com\/staging\/laser-machine\/author\/kbtest\/"}]}},"_links":{"self":[{"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/posts\/22117","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/comments?post=22117"}],"version-history":[{"count":5,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/posts\/22117\/revisions"}],"predecessor-version":[{"id":22210,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/posts\/22117\/revisions\/22210"}],"wp:attachment":[{"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/media?parent=22117"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/categories?post=22117"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/tags?post=22117"},{"taxonomy":"laser_machine","embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/laser_machine?post=22117"},{"taxonomy":"post_folder","embeddable":true,"href":"https:\/\/support.epiloglaser.com\/staging\/wp-json\/wp\/v2\/post_folder?post=22117"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}