Instrucciones de levantamiento del Fusion Ascent Los sistemas láser Ascent 12, 24 y 36 pueden levantarse y transportarse con la ayuda de dos o más personas situadas a ambos lados de la máquina.
Instrucciones de cuidado de Fusion Ascent Operating Altitude – 2,000 m (6,562 ft) maximum. Operation above 2,000 m (6,562 ft) is outside the equipment’s rated conditions. Contact Epilog before installing at higher elevations. Relative Humidity – 80% max, non-condensing Disposal (EU / EEA): This equipment is marked with the crossed-out wheeled-bin symbol and must not be (...)
Características de seguridad y cumplimiento normativo Epilog has incorporated specific safety features into the Model 19000 Laser System in order to meet the requirements of 21 CFR 1040 and the International Standard EN 60825-1. These safety features include: A safety enclosure (cabinet), which fully encloses the engraving laser and its beam path in Class 2 mode. (...)
Seguridad eléctrica Warning: The AC input power to the Epilog Model 19000 Laser System is potentially lethal and is fully contained within the cabinet. DO NOT open any of the machine’s access panels while the unit is plugged in. Opening a panel may expose the operator to the unit’s AC input power. (...)
Seguridad con el láser The Epilog Model 19000 Laser Systems are classified as a Class 2 laser product, as defined in International Standard EN 60825-1:2014/A11:2021. The Epilog Model 19000 complies with 21 CFR 1040.10 and 1040.11, the Federal Performance Standards for Light-Emitting Products, except for deviations pursuant to Laser Notice No. 56, dated May (...)