This guide covers replacing the fiber laser power supply (48V to 24V DC-DC converter) on the Fusion Galvo G100. The power supply is reached through the bottom of the engraver.
Parts Required
- LC0437 – Power Supply, +48V to +24V DC-DC
Tools Required
- T30 Torx Driver
- Phillips Screwdriver
Safety First: Ensure the engraver is completely powered off and the power cord is disconnected before removing any panels or touching internal electronics. This procedure requires laying the engraver on its back, so have a second person available to help.
Fiber Power Supply Removal
Tilt Engraver
Carefully tilt the engraver backward.
Note: The engraver is heavy. Use two people to tilt it and lower it onto its back.
Lay Engraver on Its Back
Lower the engraver until it rests on its back, giving access to the bottom panel.
Remove Bottom Panel Screws
Loosen and remove the screws around the bottom panel (highlighted in red).
Disconnect Harnesses
Follow the two harnesses from the power supply along the paths of the arrows and disconnect them.
Remove PSU Screws
Loosen and remove the four screws securing the power supply (highlighted in red).
Fiber Power Supply Installation
Tilt Engraver Upright
With a second person, tilt the engraver back toward its upright position.