This guide covers calibrating the Fusion M2 32 and 40 in a single procedure: the manual focus gauge, table home, X-Y home, the vector grid ruler bars and vector grid home.
Parts Required
- None
Tools / Materials Required
- Anodized aluminum plates
- Small Phillips screwdriver
- Sheet of paper
- Calipers, tape measure or ruler
- 3/32" Allen wrench
Calibrating the Manual Focus Gauge
Work in order. Each calibration depends on the one before it, and everything starts with a correctly calibrated focus gauge. Starting part way through will not give good results. The whole procedure takes about 10–20 minutes.
Create a Test Box
In your graphics software, start a new page and draw a black-filled box roughly 2" x 1" in the top left corner.
Engrave the Box
Manually focus on a piece of anodized aluminum and engrave the box using the anodized aluminum settings for your laser wattage.
Find the Brightest Point
Turn off the LED cabinet lighting and start the job. While it runs, use the joystick to slowly raise or lower the table until the reflection of the engraving on the aluminum is at its brightest. Stop the job and reset.
Check the Focus Gauge
Once the engraver has reset, put the manual focus gauge in place and check where its tip sits relative to the anodized aluminum plate.
Adjust the Focus Gauge
Adjust the lower part of the focus gauge so that it is barely touching the top of the anodized aluminum plate.
Setting Table Home
Prepare the Table
Lower the table about halfway and remove the vector cutting grid.
Set Vector Grid to No
In the Configuration menu on the display, set Vector Grid Installed to No and save the settings.
Restore Table Home
In the same menu, select Restore Table Home. The table rises. Put the focus gauge in place and slide a sheet of paper under it as a feeler gauge. If the gap is too big or there is no gap at all, adjust the Table Home value and save the setting.
Confirm the Setting
Lower the table to any point below the table home position. Select Restore Table Home again and confirm that the paper drags lightly as you slide it under the focus gauge. Repeat the previous step and this one until table home is correct.
Setting X-Y Home
Create a Vector Box
With the vector grid still removed, start a new page and draw a 0.5" x 0.5" vector outline box. Place it exactly 1" from the left of the page and 1" down from the top.
Score the Box
Manually focus on a piece of anodized aluminum and vector score the box using a low speed, power and frequency.
Measure the Box
Measure from the left edge and the top edge of the plate to the box outline with calipers, a tape measure or a ruler. Both should be 1" or very close. If not, note how far off each one is in X and Y.
Adjust X and Y Home
In the Configuration menu, adjust X Home and Y Home, then save. You can change both at once, but it is easier to calibrate one axis at a time.
Note: You do not need to resend the job. Select Restore X-Y Home on the display and the new settings take effect.
Repeat Until Within 0.005"
Score and measure again, adjusting X and Y Home each time, until both measurements are within 0.005" of 1".
Score a Reference Sample
Once X and Y Home are correct, run one last vector score on a new piece of anodized aluminum.
Important: Keep this sample. You need it for the vector grid steps that follow.
Setting X-Y Home for the Vector Grid
Install the Vector Grid
Install the vector grid in the engraver and lower the table about halfway.
Loosen the Ruler Bars
Loosen the Allen screws holding the left and top ruler bars on the vector grid, just enough that the bars can slide.
Set Vector Grid to Yes
In the Configuration menu, set Vector Grid Installed to Yes and save the settings.
Place the Sample
Place the scored reference sample in the top left corner of the vector grid and raise the table to the manual focus point.
Set a Temporary Home
Turn on the red dot pointer. Using the display, jog the X and Y axes to 1", 1" and set a temporary home.
Line Up the Sample
Slide the sample so the red dot lines up with the top left corner of the scored box. Tighten the top Allen screw of the left ruler bar and the left Allen screw of the top ruler bar.
Confirm the Position
Check that the red dot is still on the top left corner of the scored box.
Squaring the Vector Grid Ruler Bars
Jog to the Top Ruler Bar
Leave the table near the top and the red dot on. Jog the Y axis until the red dot lines up with the front edge of the top ruler bar, then jog the carriage to the far right: 31" on the Fusion M2 32 or 39" on the Fusion M2 40.
Square the Top Ruler Bar
Move the right end of the top ruler bar until the red dot lines up with its front edge, then tighten that Allen screw.
Check Along the Top Bar
Jog the head back to the left and make sure the red dot stays on the front edge of the top ruler bar from far left to far right. Tighten the remaining top ruler bar screws.
Find the Left Line
Place the scored sample in the top left corner of the bed. Jog the head to 1", where the red dot lines up with the left vertical line of the scored box.
Jog to the Front
Jog the Y axis to the front of the engraver: 19" on the Fusion M2 32 or 27" on the Fusion M2 40.
Square the Left Ruler Bar
Slide the sample down the left ruler bar and line the red dot up with the left vertical line of the scored box. Adjust the left ruler bar to match and tighten its Allen screw.
Check Along the Left Bar
Using the scored box as a reference, jog the head back toward home and make sure the red dot stays on the left vertical line. Tighten the remaining Allen screws.
Note: The right side ruler bar can be left alone.
Calibrating Vector Grid Home
Prepare the Table
The vector grid should be installed and Vector Grid Installed set to Yes. Lower the table about halfway.
Restore Table Home
In the Configuration menu, select Restore Table Home. The table rises. Put the focus gauge in place and slide a sheet of paper under it. If the gap is too big or there is no gap at all, adjust the Vector Grid Home value and save the setting.
Confirm the Setting
Lower the table below the home position, select Restore Table Home again and confirm the paper drags lightly under the focus gauge. Repeat the previous step and this one until vector grid home is correct.