Table Level Procedure

How do I check and adjust the Zing table level?

Introduction

This guide covers checking and adjusting the table level on the Zing, so the laser delivers even power across the whole engraving area.

Parts Required

  • None

Tools Required

  • 3/32" Allen Wrench
  • Adjustable Wrench


Checking the Table Level

Step 1

Press Focus

With the engraver on and no material in it, press the Focus button on the keypad.

Step 2

Lower the Focus Stylus

Lower the focus stylus and slide it all the way to the right side of the engraving area.

Note: To tell whether the table is in focus, swing the stylus. It should tap against the table but not get stuck.

Step 3

Focus the Table

Use the Up and Down arrow keys to raise or lower the table until it barely touches the focus stylus.

Step 4

Power Off Engraver

Turn off the engraver.

Step 5

Check Each Corner

Move the focus stylus to each corner of the table. The table should be in focus at every corner. If a corner is not, continue to the next section.


Adjusting the Table Level

Step 6

Locate the Lead Nut Clamp

Find the lead nut clamp at the corner you need to adjust. There is one at each corner of the table.

Step 7

Loosen the Clamp Screw

Reaching under the table through the front door, loosen the lead nut clamp screw with a 3/32" Allen wrench until it spins freely.

Step 8

Turn the Lead Nut

Turn the plastic lead nut by hand, or with an adjustable wrench, until the focus stylus is just touching the table.

Step 9

Tighten the Clamp Screw

Retighten the lead nut clamp screw with the 3/32" Allen wrench.

Step 10

Repeat for Each Corner

Repeat this section for every corner that is out of level, then check all four corners again.