Top Door Gas Shock Replacement

How do I replace the gas shock on the top door of the Fusion Pro 32 and 48?

Introduction

This guide covers replacing a top door gas shock on the Fusion Pro 32 and 48. The gas shock snaps onto ball studs and is held by a locking clip at each end.

Parts Required

  • CS0483 – Shock, Top Door, 48×36 (Fusion Pro 48)
  • HT0429 – Shock, Gas, Top Door, F32 (Fusion Pro 32)

Tools Required

  • Small Flathead Screwdriver


Gas Shock Removal

Step 1

Turn Off Engraver

Turn off the engraver.

Step 2

Disconnect from Power

Unplug the engraver from its power source.

Step 3

Open the Top Door

Open the top door of the engraver.

Step 4

Remove the Top Clip

Use a small flathead screwdriver to pry the locking clip off the top of the gas shock.

Step 5

Remove the Bottom Clip

Use a small flathead screwdriver to pry the locking clip off the bottom of the gas shock.

Step 6

Remove the Gas Shock

Support the top door so it cannot fall, then remove the gas shock from the ball stud mounts.

Important: The top door can drop once the gas shock is removed. Hold or prop it open until the new shock is installed.


Gas Shock Installation

Step 7

Install the New Gas Shock

Install the new gas shock on the ball studs with the barrel of the shock facing up: CS0483 for the Fusion Pro 48 or HT0429 for the Fusion Pro 32.

Step 8

Install the Top Clip

Install the locking clip on the top of the gas shock.

Step 9

Install the Bottom Clip

Install the locking clip on the bottom of the gas shock.

Step 10

Power On

Reconnect the engraver to power and turn it on.

Step 11

Check Door Movement

Open and close the top door to make sure it moves properly.

Was this helpful?