Manual Focus Gauge (MFG) Replacement – Fusion Pro 32 & 48

How do I replace the manual focus gauge in the Fusion Pro 32 and 48?

Introduction

This guide covers replacing the manual focus gauge (MFG) on the Fusion Pro 32 and 48. The MFG is held on the lens carriage by a single screw, and its length is set to the engraver’s calibrated focus height after installation.

Parts Required

  • CS1032 – Assy, Manual Focus Gauge

Tools Required

  • 3/32" Allen Wrench


MFG Removal

Step 1

Turn Off Engraver

Turn off the engraver.

Step 2

Remove the MFG

Loosen and remove the 3/32" Allen screw that holds the manual focus gauge in place, then remove the MFG.


MFG Installation

Step 3

Install the New MFG

Place the new CS1032 manual focus gauge in position. Install and tighten the 3/32" Allen screw.

Step 4

Turn On Engraver

Turn on the engraver.

Step 5

Match the MFG to Focus Height

Use the auto focus feature to move the table to the calibrated focus height. Then lengthen or shorten the MFG so its tip matches that focus height.

Was this helpful?

Yes
No
Thanks for your feedback!