This guide covers replacing the Carriage Camera PCB (which also contains the Auto Focus sensor) and the X-Axis USB-C cable on the 16000 Series Fusion Pro. Camera recalibration is required after replacing the PCB.
Safety First: Ensure the engraver is completely powered off and the power cord is disconnected before removing any panels or touching internal components.
Carriage Camera PCB Replacement
Power Off Engraver
Turn off the engraver.
Remove the PCB Screws
Remove the eight (8) T4 Torx screws that secure the Carriage Camera PCB.
Install the New PCB
Set the new Carriage Camera PCB in place and secure it with the eight (8) T4 Torx screws.
Note: If you are not replacing the USB-C cable, reconnect it to the new PCB, reinstall the carriage cover and skip to reconnecting power.
USB-C Cable Replacement
Remove the Cable Chain Screws
Remove the two (2) T8 Torx screws on each end of the cable chain.
Pull the Cable Through the Chain
Pull the USB-C cable through the cable chain.
Remove the Right-Side Panel
Using a 5/32″ hex wrench, remove the right-side panel of the machine.
Remove the X-Axis Drive PCB Cover
Loosen the four (4) Phillips head screws and remove the X-Axis Drive PCB cover.
Pull Out the Old Cable
Pull the USB-C cable out through the right side of the machine.
Unplug the Extension Cable
Unplug the USB-C cable from the extension cable to the left of the motor.
Route the Replacement Cable
Feed the replacement cable back through the machine and cable chain.
Reattach the Cable Chain
Reattach the cable chain with the two (2) T8 Torx screws on each end.
Connect the Extension Cable
Plug the USB-C cable into the extension port by the motor.
Secure the Cable
Use replacement cable ties to attach the USB-C cable to the X-Axis rail.
Replace All Covers
Reinstall the X-Axis Drive PCB cover, the right-side panel and the carriage cover.
Recalibrate the Cameras
After replacing the Carriage Camera PCB, you must recalibrate your cameras. Follow the Camera Calibration article to complete this.