This guide covers replacing the table switch board (z-axis PCB) on the Fusion Pro 32 and 48. The board is mounted at the front right of the engraver. After installation, the motor drives and FPGA are updated from the display.
Parts Required
- CS0359 – PCBA, Z-Axis Switches
Tools / Materials Required
- 5/32" Allen Wrench
- 5/16" Nut Driver or Adjustable Wrench
- Phillips Screwdriver
- Anti-Static Strap
- Pencil or Marker
Safety First: Ensure the engraver is completely powered off and the power cord is disconnected before removing any panels or touching internal components.
Table Switch Board Removal
Turn Off Engraver
Turn off the engraver.
Put On Anti-Static Strap
Place the anti-static strap around your wrist and attach the clamp to a bare metal surface on the engraver.
Locate the Table Switch Board
Locate the table switch board (z-axis PCB) at the front right side of the engraver.
Mark the Board Height
Use a pencil or marker to mark the engraver chassis at the top edge of the board (red arrow). This mark is used to set the height of the replacement board.
Disconnect Cables
Disconnect the display port cable and the two electrical harnesses from the board (highlighted in purple).
Remove Board Nuts
Loosen and remove the four 5/16" nuts that secure the board to the engraver chassis (circled in red).
Note: You may need to loosen the air assist pump to reach the lowest nuts. It is held to the bottom of the engraver by four Phillips screws.
Table Switch Board Installation
Install Board Nuts
Install, but do not fully tighten, the four 5/16" nuts that secure the board to the engraver chassis.
Align With the Mark
Lift the board until its top edge lines up with the mark made in step 6.
Tighten Board Nuts
Tighten the four 5/16" nuts that secure the board to the engraver chassis.
Connect Cables
Connect the display port cable and the two electrical harnesses to the board.
Program the Table Switch Board
Open the Settings Menu
On the display, press the gear icon in the upper right corner to open the Settings menu.
Update Motor Drives and FPGA
Select Motor Drives and FPGA, then press Update.
Important: Do not power off the engraver during the update. It is normal for the display to turn off while the update runs. When the update has been applied, the engraver prompts you to restart.
Restart When Prompted
When the engraver prompts you to restart, power cycle the engraver.