Coherent to Epilog Laser Replacement

Introduction

This guide covers upgrading an Epilog Mini or Helix from the original Coherent C40 laser tube to an Epilog laser tube. You remove the old laser tube, install the MT266 adapter bracket that the new tube hangs on, then hang and connect the new tube. Depending on your machine, you may also need to install a new fan tray and rotate the power supply on a new bracket; each of those sections says which machines need it. Read through the whole procedure before you start. Directions such as left-hand and right-hand are given as if you are facing the back of the machine, where all of this work is done.

Parts Required

  • Epilog Replacement Laser Tube
  • Adapter Bracket (MT266), with shoulder screw, washer and mounting screws
  • Fan Tray (Mini 24 and Helix with 4 fans only)
  • PSU Bracket (MT525) and Rear Panel (silver PSU with the label facing out only)

Tools Required

  • Phillips Screwdriver
  • SAE (Inch) Allen Wrench Set
  • Locking Pliers
  • 5/16″ Nut Driver or Wrench

Safety First: Turn off the engraver and unplug it from power before you start.


Laser Tube Removal

Step 1

Turn Off the Engraver

Turn off the engraver.

Step 2

Disconnect from Power

Unplug the engraver from its power source.

Step 3

Remove the Rear Panel

From the back of the machine, remove the screws (red arrows) that hold the rear panel with a Phillips screwdriver, and take the panel off. The laser tube is the silver finned unit directly above the exhaust port.

Step 4

Disconnect the Red Dot Pointer

The red dot pointer is on the right side of the laser tube. Follow its thin red and black wires to the black connector, press the tab and unplug the connector.

Step 5

Disconnect the Data Cable

Press the tab on the gray data cable and unplug it from the left side of the laser tube.

Step 6

Disconnect the Power Harness

Follow the red and black power wires from the laser tube to the white connector, and unplug the connector.

Step 7

Loosen the Thumb Screws

Loosen the three green thumb screws (one on the left, two on the right) with a Phillips screwdriver until they stop.

Note: The thumb screws are captive and will not come all the way out of the bracket.

Step 8

Slide the Laser Tube to the Left

Slide the laser tube to the left until it stops, about 1/2″ (12 mm). This frees its bracket slots from the shoulder screws.

Step 9

Remove the Laser Tube

Carefully lift the laser tube up and out of the engraver, and set it on a flat table.

Caution: The laser tube can weigh 10 to 20 lbs (4.5 to 9 kg). Use proper lifting technique, and get help if you need it.


Installing the Adapter Bracket

Step 10

Remove the Left Shoulder Screw

Unscrew and remove the left-hand shoulder screw (circled) that the old tube hung on. You will not reuse it.

Step 11

Remove the Left Standoff

Grip the left-hand spacing standoff (circled) with locking pliers and break it away from the back wall. This does not damage the engraver.

Step 12

Locate the Adapter Bracket

Find the MT266 adapter bracket in the upgrade kit, along with its shoulder screw, washer and mounting screws.

Step 13

Install the Shoulder Screw in the Bracket

Install the new shoulder screw and washer in the top left-hand corner of the MT266 adapter bracket.

Step 14

Install the Adapter Bracket

Line up the two screw holes on the right-hand side of the adapter bracket with the screw holes in the back wall, and fasten the bracket with the screws provided.


Installing the New Fan Tray

Note: Do this section only on a Mini 24 or Helix that has 4 fans with space for 6. If your machine already has 6 fans, or it is a Mini 18, skip to Installing the New Laser Tube.

Step 15

Locate the Fan Tray

Find the fan tray along the top of the back opening (boxed).

Step 16

Disconnect the Fan Harness

Unplug the fan wire harness at the left-hand side of the fan tray.

Step 17

Remove the Harness Holder

Remove the wire harness holder (circled).

Step 18

Remove the Fan Tray

With a 5/16″ nut driver, remove the nuts (circled) on the left and right sides of the fan tray, and take the tray out.

Step 19

Install the New Fan Tray

Insert the new fan tray and fasten it with the nuts.

Step 20

Reconnect the Fan Harness

Plug the fan wire harness back in and secure it with the harness holder.


Rotating the Power Supply

Caution: The power supply (PSU) can hold a hazardous electrical charge even after it is unplugged. Make sure the engraver is off and unplugged, do not touch electrical contacts, leads or damaged wires with your bare hands, and never open the PSU housing.

Step 21

Identify Your Power Supply

On some machines the PSU must be rotated on a new bracket to make room for the new laser tube. Compare your PSU to the pictures:

  • Silver PSU, label facing out (A): continue with this section.
  • Silver PSU, label facing up (B) or black PSU (C): skip to Installing the New Laser Tube.

Step 22

Disconnect the PSU Output

Follow the red and black wires from the PSU to the white connector, and unplug it. Do this for every pair of red and black wires.

Step 23

Disconnect the PSU Input

Follow the green, white and black wires from the PSU to the white connector, and unplug it.

Step 24

Remove the Power Supply

Loosen the two green thumb screws on the left and right sides of the PSU, and lift the PSU out of the engraver.

Step 25

Remove the Old PSU Bracket

Set the PSU on a flat surface with the mounting bracket facing up and the thumb screws toward you. Remove the four mounting screws (red arrows) and discard the bracket. Keep the screws.

Step 26

Roll the Power Supply

Roll the PSU toward you so the side with the label faces directly away from you.

Step 27

Install the New PSU Bracket

Set the new MT525 bracket on top of the PSU with its thumb screws toward you. Line up the holes, and fasten the bracket with the four mounting screws.

Step 28

Reinstall and Reconnect the Power Supply

Set the PSU back in the engraver and tighten the green thumb screws. Plug the red and black output connectors and the green, white and black input connector back in.

Note: If your engraver has two PSUs, repeat this section for the second one.


Installing the New Laser Tube

Step 29

Hang the New Laser Tube

Line up the slots in the new laser tube’s mounting brackets with the shoulder screws, and hang the tube on them.

Step 30

Slide the Laser Tube to the Right

Slide the laser tube to the right until it stops, about 1/2″ (12 mm), so the slots seat on the shoulder screws.

Step 31

Tighten the Thumb Screws

Tighten the three green thumb screws (circled) to hold the laser tube in place.

Step 32

Reconnect the Laser Tube

Plug the red dot pointer connector, the gray data cable and the red and black power connector back in.

Step 33

Install the Rear Panel

Tuck any loose wires back into the engraver, and reinstall the rear panel with its screws.

Note: If you rotated the power supply, use the new rear panel that came with the PSU bracket. It makes room for the new PSU position.

Step 34

Reconnect Power

Plug the engraver back in and turn it on.

Step 35

Align the Laser

Align the laser before you use the engraver. See Laser Alignment – Mini / Helix MT for the steps.

Was this helpful?

Yes
No
Thanks for your feedback!
  • Date: