X-Axis Assembly Replacement – Fusion Pro 32 & 48

How do I replace the x-axis assembly in the Fusion Pro 32 and 48?

Introduction

This guide covers replacing the complete x-axis assembly on the Fusion Pro 32 and 48. The x-axis assembly contains circuit boards, cameras and a motor, so after installation the carriage camera and the engraver peripherals are updated from the display.

Parts Required

  • CS0400 – Assy, X-Axis Rail, 32×20 (Fusion Pro 32)
  • CS1200 – Assy, X-Axis Rail, 48×36 (Fusion Pro 48)

Tools Required

  • 5/32" and 7/64" Allen Wrenches
  • 5/16" Nut Driver
  • Phillips Screwdriver

Safety First: Ensure the engraver is completely powered off and the power cord is disconnected before removing any panels or touching internal components.


X-Axis Assembly Removal

Step 1

Turn Off Engraver

Turn off the engraver.

Step 2

Disconnect from Power

Unplug the engraver from its power source.

Step 3

Remove Side Panels

Remove the left and right panels of the engraver by loosening the 5/32" cam locks.

Step 4

Center the X-Axis Assembly

Manually move the x-axis assembly to the middle of the engraver.

Step 5

Loosen Lens Tube Collar

Loosen the Phillips screw on the lens tube retaining collar (circled in red). Hold the lens tube so it does not fall.

Step 6

Remove Lens Tube

Remove the lens tube.

Step 7

Remove Bellows

Remove the left and right bellows and the backing plate by loosening the six 5/16" nuts.

Step 8

Loosen Drive Board Cover Screws

Loosen, but do not remove, the four Phillips screws that hold the x-axis drive board cover (circled in red).

Step 9

Remove Drive Board Cover

Remove the x-axis drive board cover.

Step 10

Disconnect Drive Board Connectors

Disconnect the seven electrical connectors from the x-axis drive board (red arrows).

Step 11

Disconnect Air Tubing

Disconnect the air tubing from the elbow connector on the right side of the x-axis assembly (highlighted in purple).

Note: The air tubing is held by a retaining fixture. Press the tubing into the fixture, then hold the orange retaining ring against the fixture and pull the tubing away from it.

Step 12

Remove Drive Board Housing Screws

Loosen and remove the four 7/64" hex screws that hold the x-axis drive board housing (circled in red).

Step 13

Remove Drive Board Housing

Remove the x-axis drive board housing.

Step 14

Remove X-Axis Fasteners

Remove or loosen the four 5/32" fasteners that secure the x-axis assembly to the y-axis bearings: two on the right side (top) and two on the left side (bottom).

Step 15

Lift the X-Axis Assembly

Lift the x-axis assembly up to clear the locator pins on the left and right y-axis bearing blocks.

Step 16

Remove the X-Axis Assembly

Slide the x-axis assembly out of the engraver through the right side.


X-Axis Assembly Installation

Step 17

Install the New X-Axis Assembly

Slide the new x-axis assembly into the engraver through the right side of the machine: CS0400 for the Fusion Pro 32 or CS1200 for the Fusion Pro 48.

Step 18

Seat on the Bearing Blocks

Place the x-axis assembly on the y-axis bearing blocks, making sure the locator pins go into the upper bearing block assembly.

Step 19

Install X-Axis Fasteners

Install or tighten the four 5/32" fasteners that secure the x-axis assembly to the y-axis bearings: two on the right side and two on the left side.

Step 20

Position Drive Board Housing

Position the x-axis drive board housing over its mounting holes.

Step 21

Install Drive Board Housing Screws

Install and tighten the four 7/64" hex screws that hold the x-axis drive board housing.

Step 22

Reconnect Air Tubing

Reconnect the air tubing to the elbow fitting on the right side of the x-axis assembly.

Note: Insert the tubing into the collar of the retaining fixture, then gently pull on it to make sure it is secure.

Step 23

Reconnect Drive Board Connectors

Reconnect the seven electrical connectors to the x-axis drive board.

Note: Each connector on the drive board is unique and only fits one receptacle.

Step 24

Install Drive Board Cover

Install the x-axis drive board cover and tighten the four Phillips screws.

Step 25

Install Bellows

Install the backing plate and bellows. Install and tighten the six 5/16" nuts that hold them in place.

Step 26

Insert the Lens Tube

Insert the lens tube in the lens assembly with the notch in the tube facing the rear of the engraver (red arrow). Hold the lens tube so it does not fall.

Step 27

Tighten Lens Tube Collar

Tighten the Phillips screw on the lens tube retaining collar.

Step 28

Install Side Panels

Install the left and right panels of the engraver.

Step 29

Power On

Reconnect the engraver to power and turn it on.


Updating the Carriage Camera

Step 30

Open the Settings Menu

On the display, press the gear icon to open the Settings menu.

Step 31

Open Advanced Settings

Press and hold the word Settings to open the Advanced Settings menu.

Step 32

Open the Camera Tab

Open Diagnostics, scroll to the Camera tab and press Test & Update.

Step 33

Update the Camera

Press Update Cameras.

Step 34

Wait for Success

Let the engraver finish the update. A success message appears when it is done.


Updating the Peripherals

Step 35

Open the Settings Menu

On the display, press the gear icon in the upper right corner to open the Settings menu.

Step 36

Open Peripheral Update

Press Program to open the Peripheral Update menu.

Step 37

Update Motor Drives and FPGA

Select Motor Drives and FPGA, then press Update.

Important: Do not power off the engraver during the update. It is normal for the display to turn off while the update runs. When the update has been applied, the engraver prompts you to restart.

Step 38

Restart When Prompted

When the engraver prompts you to restart, power cycle the engraver.

Calibrate and Align

After replacing the x-axis assembly, complete a full focus calibration and laser alignment.