Skip to main content
Table / Grid
8000

Filters


Getting Started (5)
Usage and Operation (89)
Service and Repair (40)

Filters


Getting Started (5)
Usage and Operation (89)
Service and Repair (40)

Table Belt Install – Mini / Helix

How do I replace the Helix Z-belt?

Introduction

This guide covers replacing the table (Z-axis) belt on the Mini and Helix. The table belt drives the vertical movement of the engraving table.

Parts Required

  • Table (Z-Axis) Belt

Tools / Materials Required

  • Phillips Screwdriver
  • Long 5/16" Nut Driver
  • 3/32" Hex Wrench
  • Wire Cutters
  • Sharpie Marker

Safety First: Ensure the engraver is completely powered off and the power cord is disconnected before removing any panels or touching internal components.


Belt Removal

Step 1

Raise the Table

With the engraver on, raise the table to its top position.

Step 2

Power Off Engraver

Turn off the engraver.

Step 3

Disconnect From Power

Unplug the power cord from the engraver.

Step 4

Remove the Side Panels

Remove both side panels.

Step 5

Remove the Front Panel

Remove the front service panel.

Step 6

Disconnect the Motor Lead

Disconnect the table motor lead.

Step 7

Disconnect the Ribbon Cable

Disconnect the white ribbon cable from the control board.

Step 8

Mark the Tension Screw

A 3/32" hex screw sets the belt tension. Before removing the bracket, color the visible thread between the bracket and the fixed nut with a Sharpie, including the edge of the thread at the fixed nut.

Step 9

Remove the Bracket Nuts

Reaching in from the side with a long 5/16" nut driver, remove the two nuts on the motor bracket.

Step 10

Remove the Tension Screw

Unscrew the 3/32" hex tensioning screw and remove the motor and bracket.

Step 11

Remove the Old Belt

Turn the belt on its flat edge and slip it out under the left drive pulley, then do the same at the right drive pulley. Remove the old belt.


Belt Installation

Step 12

Route the New Belt

Route the new belt as shown. It is easiest to put it on the left drive pulley first, then loop it around the right drive pulley.

Step 13

Fit the Belt on the Motor

Getting the belt around the motor pulley is a little tricky. Pull the silver spindle down about 1/4" (6.35 mm), set the motor and bracket into the engraver at an angle, and slip the belt squarely onto the spindle.

Step 14

Seat the Bracket

Set the motor bracket on the fixed screws and start the two nuts. Do not tighten them yet.

Step 15

Set the Belt Tension

Thread in the hex tensioning screw until the edge of the Sharpie mark is at the edge of the fixed nut, exactly where it was before.

Important: The mark must be in exactly the same place as before; this sets the belt tension.

Step 16

Tighten the Bracket Nuts

Tighten the two nuts holding the motor bracket.

Step 17

Back Off the Left Nut

Loosen the left nut a quarter turn.

Step 18

Reconnect the Motor Lead

Reconnect the motor lead.

Step 19

Reconnect the Ribbon Cable

Reconnect the white ribbon cable to the control board.

Step 20

Reinstall the Panels

Reinstall the front service panel and both side panels.

Step 21

Reconnect Power and Test

Plug the power cord back in, turn on the engraver and check that the table moves up and down correctly.

Was this helpful?

Yes
No
Thanks for your feedback!
  • ID:
    KA-01143
  • Date:
    11/05/2026