This guide covers aligning the CO2 laser in the Fusion Ascent. You first align the red dot pointer to the laser, then use the red dot to adjust the mirrors so the beam is centered in every corner of the table, and finally check that the beam leaves the lens carriage straight down. Read the whole guide before you start. Directions such as left-hand and right-hand are given as if you are facing the front of the machine. In the images, orange marks screws and parts to remove, blue marks screws to adjust, and yellow shows where to tap on the touch screen.
Laser Safety: This procedure fires the laser with covers removed. Everyone in the area must wear safety glasses while you work, and only fire the laser with the top door closed.
When to Align the Laser
Align the laser if any of the following apply:
- You notice a general loss of power.
- Engraving fades in one corner of the table.
- You lose power in certain areas of the table.
- You replaced the X-axis rail.
- You replaced the laser tube.
- You replaced a mirror.
- The engraver has been moved or shipped.
Before You Start
Table Positions
The table is divided into four positions, one in each corner. Each position matches the mirror you adjust there: at Position 1 you adjust only Mirror 1, at Position 2 only Mirror 2, and at Position 3 only Mirror 3. Position 4 is used to check the result.
The Mirrors
Mirrors 1 and 2 are behind the alignment access cover at the rear left-hand corner of the engraver. Mirror 3 is on the left-hand end of the X-axis rail. Mirror 4 is on top of the lens carriage and is adjusted last.
The Alignment Menu
The Alignment menu (Settings > Alignment) has a button for each corner that moves the lens carriage there, and an Activate button that fires the laser for alignment.
Alignment Procedure
Procedure 1: Align the Red Dot Pointer to the Laser
The red dot pointer must follow exactly the same path as the CO2 laser. If the two are not aligned to each other before you adjust the mirrors, the rest of the alignment will not work.
Note: If you are aligning because you replaced Mirror 3 or the X-axis rail, skip to Procedure 2. For every other reason, start here.
Remove the Alignment Access Cover
At the rear left-hand corner of the engraver, remove the four 5/32″ button head screws (orange) that hold the alignment access cover, and take the cover off.
Install the Alignment Target
Open the top door. Push the alignment target into the opening on the left-hand side of the lens carriage, where the beam enters, with the bullseye facing out to the left. It fits snugly into the carriage optic opening.
Cover the Target with Tape
Put a small square of masking tape over the face of the alignment target, then close the top door.
Open Settings
On the touch screen, tap the Settings icon (gear) in the top right-hand corner.
Move to Position 4
Tap Bottom Right. The lens carriage moves to Position 4, the front right-hand corner of the table.
Fire the Laser
With the top door closed, tap Activate to fire the laser at the tape. Use short, quick taps: the smaller and lighter the burn mark, the easier it is to center the red dot in it.
Note: All interlocked doors must be closed for the laser to fire. If you get no mark on the tape, set Power to 15–20% and check that the top door is fully closed.
Check the Burn Mark
Open the top door and look at the tape. There should be a small burn mark where the laser hit it. Leave the tape in place.
Turn On the Red Dot Pointer
Tap the red dot pointer icon at the bottom of the screen. The icon turns green while the pointer is on.
Find the Red Dot
Look for the red dot on the tape. If it is not in the burn mark, the red dot pointer needs adjusting.
Move the Red Dot onto the Burn Mark
You reach the red dot pointer’s adjustment screws with the 3/32″ Allen wrench through the openings in the top of the engraver, at the rear left-hand corner. This is the only step that is different between lasers: the 30–40 W and 60–80 W lasers have different mounts. Open the section for your laser. (The wattage is shown on the touch screen under Settings, next to Laser, and on the label on the back of the engraver.)
-
30–40 W Laser
Reach through the three openings and turn the adjustment screws (blue) to move the red dot into the center of the burn mark. Each screw moves the dot in the direction shown:
- Screw 1: moves the dot diagonally, lower left to upper right.
- Screw 2: moves the dot left and right.
- Screw 3: moves the dot diagonally, upper left to lower right.
- 60–80 W Laser
Note: Take your time here. The better the red dot and the laser line up, the better the rest of the alignment works.
Check Again
Put a fresh piece of tape on the target and repeat from step 8. When the red dot sits in the center of a new burn mark, the red dot pointer is aligned to the laser. Leave the red dot pointer on for the next procedure.
Procedure 2: Align the Laser in Each Corner
Now you use the red dot to adjust Mirrors 1, 2 and 3 so the beam hits the center of the target in all four corners of the table. Leave the alignment target in the carriage (you can remove the tape).
Remove the Alignment Access Cover
If you skipped Procedure 1, remove the four 5/32″ button head screws (orange) from the alignment access cover at the rear left-hand corner, and take the cover off.
Remove the Left Side Panel
Remove the left-hand side panel to reach the mirrors and see the target at the left-hand side of the table.
Move to Position 1
In the Alignment menu, tap Top Left. The lens carriage moves to Position 1, the rear left-hand corner.
Adjust Mirror 1
Mirror 1 is behind the alignment access cover. With the 3/32″ Allen wrench, turn its three adjustment screws (blue) until the red dot is in the center of the target. Each screw moves the dot in the direction shown.
Note: The carriage is close to the left-hand side of the machine in this position, so the dot can be hard to see. If so, free the top of the bellows from the X-axis (next step).
Free the Bellows (If Needed)
Grasp the top of the left-hand bellows where it meets the X-axis assembly and gently pull it away to separate the hook-and-loop fastener. Reattach it when you are finished.
Move to Position 2
Tap Bottom Left. The lens carriage moves to Position 2, the front left-hand corner.
Adjust Mirror 2
Mirror 2 is also behind the alignment access cover. With the 3/32″ Allen wrench, turn its adjustment screws (blue) until the red dot is in the center of the target.
Repeat Positions 1 and 2
Go back to step 16, re-center the dot at Position 1 with Mirror 1, then repeat from step 19 for Position 2 with Mirror 2.
Note: You may need to go back and forth several times. Each pass the dot moves less between the two positions. Continue until the dot stays in the center at both positions.
Move to Position 3
Tap Top Right. The lens carriage moves to Position 3, the rear right-hand corner.
Adjust Mirror 3
Mirror 3 is on the left-hand end of the X-axis rail. With the 3/32″ Allen wrench, turn its adjustment screws (blue) until the red dot is in the center of the target.
Repeat Positions 1 to 3
Check Positions 1 and 2 again (steps 16 to 21), then Position 3. Continue until the dot stays in the center of the target at all three positions.
Check Position 4
Tap Bottom Right to move the lens carriage to Position 4, the front right-hand corner.
Check the Dot
If the mirrors are aligned, the red dot is inside the center ring of the target. If it is not, go back to step 16 and continue the alignment.
Procedure 3: Perpendicular Alignment
The beam must leave the carriage mirror (Mirror 4) straight down through the focus lens. If it is at an angle, the dot moves as the table moves up and down.
Open the Focus Menu
Remove the alignment target from the carriage. With the red dot pointer still on, tap the Focus icon at the bottom of the touch screen.
Raise the Table to the Focus Gauge
Hang the manual focus gauge on the carriage. Use the Nudge up arrow to raise the table until the bottom of the gauge just touches the table surface. Then remove the gauge.
Center the Target Under the Dot
Place the alignment target on the table, under the lens carriage, with the red dot in the center of the bullseye.
Lower the Table 3 Inches
Use the Joystick to lower the table until CO2 Focus reads about 3.000.
Check the Dot
Check where the red dot is on the target. If it moved off the center, adjust Mirror 4 (next step). If it stayed in the center, skip to the final step.
Adjust Mirror 4
Mirror 4 is on top of the lens carriage. With the 3/32″ Allen wrench, turn its three adjustment screws (blue) to bring the red dot back to the center of the target. Each screw moves the dot in the direction shown.
Note: If the mirror has been adjusted a lot, center it first: tighten each of the three screws one full turn at a time, in any order, until all three are snug. Then loosen each screw one full turn at a time until each has been loosened three full turns.
Raise the Table and Repeat
Raise the table back up to the focus gauge (step 28) and check the dot again. Repeat steps 28 to 32 until the dot stays in the center of the target as you raise and lower the table.
Reinstall the Panels
Turn off the red dot pointer. Reattach the bellows if you freed it, then install the left-hand side panel and the alignment access cover with their screws.
Verify the Alignment
Create a Test File
In your graphics software, create a page the size of your table and put a small black filled box in each of the four corners.
Focus on Your Test Material
Use a scrap of material you know well, such as wood or acrylic (metal does not work for this test). Put it in the upper left-hand corner of the table and focus on it manually. Do not move the table up or down for the rest of the test.
Engrave Each Corner
Engrave the upper left-hand box with your usual settings for that material. Move the material to the next corner, engrave only that corner’s box, and repeat until all four boxes are engraved.
Compare the Boxes
All four boxes should have the same color and the same depth. A well-aligned machine uses the same settings in every corner; you should not need more power or less speed in one corner to get the same result.