How do I replace the z-axis belt in the Fusion Maker, Edge, and Pro 24 and 36?

Introduction

This guide covers replacing the table (z-axis) belt on the Fusion Maker, Fusion Edge and Fusion Pro 24 and 36. The belt runs around the four lead screw pulleys under the table and is tensioned by the table motor.

Parts Required

  • RC0596 – Belt, Table, Z24 (24 x 12 table)
  • LC0504 – Belt, Table 24×24 (24 x 24 table)
  • LC0726 – Belt, Table, 36×24 (36 x 24 table)

Tools / Materials Required

  • 5/32" Allen Wrench
  • Pencil or Marker

Safety First: Ensure the engraver is completely powered off and the power cord is disconnected before removing any panels or touching internal components.


Table Belt Removal

Step 1

Turn Off Engraver

Turn off the engraver.

Step 2

Disconnect from Power

Unplug the engraver from its power source.

Step 3

Remove Right Panel

Remove the right panel of the engraver.

Step 4

Remove Front Panel and Crumb Tray

Remove the front access panel and the crumb tray of the engraver.

Step 5

Mark the Motor Position

Use a pencil or marker to mark the engraver chassis at the leading edge of the table motor bracket (shown in red). This mark is used to set the belt tension during installation.

Step 6

Disconnect Motor Harness

Disconnect the table motor electrical harness.

Step 7

Release Belt Tension

Loosen, but do not remove, the table motor tensioner thumbscrew (circled in red) to release the tension on the table belt.

Step 8

Remove Motor Mount Screws

Loosen and remove the four 5/32" Allen screws on the table motor mount (circled in red).

Step 9

Remove the Table Motor

Remove the table motor assembly.

Step 10

Free the Belt from the Pulleys

Press the table belt flat against the bottom of the engraver chassis and slip it out from under each lead screw pulley.

Step 11

Remove the Belt

Once the belt is free of every lead screw pulley, remove it from the engraver.


Table Belt Installation

Step 12

Place the New Belt

Place the new table belt in the bottom of the engraver.

Step 13

Wrap the Lead Screw Pulleys

Press the belt flat against the bottom of the engraver chassis and slip it under each lead screw pulley, with the toothed side of the belt wrapping around the pulley. Repeat for all four lead screw assemblies.

Reference

Table Belt Routing

The new belt (green) wraps around each lead screw pulley and the motor opening as shown for your table size.

24 x 12 Table

24 x 12 Table

24 x 24 Table

24 x 24 Table

36 x 24 Table

36 x 24 Table

Step 14

Feed the Motor Opening

Insert the belt into the opening for the table motor, leaving enough slack for the belt to wrap around the motor drive pulley when the motor is installed.

Step 15

Install the Table Motor

Install the table motor with the belt around its drive pulley. Install, but do not fully tighten, the four 5/32" Allen screws on the motor mount.

Step 16

Connect Motor Harness

Connect the table motor electrical harness.

Step 17

Tension the Belt

Begin tightening the table motor tensioner thumbscrew to tension the belt.

Step 18

Align With the Mark

Keep tightening the thumbscrew until the motor bracket lines up with the mark made in step 5. Then tighten the four 5/32" Allen screws on the motor mount.

Step 19

Install Front Panel and Crumb Tray

Install the front access panel and the crumb tray of the engraver.

Step 20

Install Right Panel

Install the right panel of the engraver.

Step 21

Power On

Reconnect the engraver to power and turn it on.