Work through this checklist before replacing a CO2 laser tube. Most lasers that seem to have no output or low output turn out to have a different cause: an open interlock, dirty optics, alignment or focus. This guide covers the Fusion Edge, Maker, Pro and Ascent. Where a step is different on the Ascent, open the panel for your machine. If the laser has not been used for more than a month, follow the Extended Cold Start Guide first.
Materials
- Masking tape
- Card stock
- 0.025″ anodized aluminum
- Alignment target
Tools Required
- Laser safety glasses
- 5/32″ Hex Wrench
- 3/32″ Hex Wrench
- #2 Phillips Screwdriver
- Manual focus gauge
- Optics cleaning supplies
Safety First: Some checks fire the laser with covers removed. Everyone in the room must wear laser safety glasses during those steps. Turn off and unplug the engraver before removing any panel, and never touch areas marked with the high-voltage symbol.
No Output
The laser does not mark at all. Start at Part 1.
Low Output
Marks are weak, or you keep raising power and lowering speed. Start at Part 2.
Part 1: No Output
Safety Interlocks
Check the Interlock LEDs
The status LEDs are on the right side of the machine, below the control panel. Close all doors. The interlock LEDs must be on whenever the doors are closed, and must stay on for the whole time a job runs.
Note: No interlock LEDs? Make sure every door is fully closed, check the top door seal for debris, and look for an unusual gap between the top door and the chassis. If the interlock LEDs still do not light, troubleshoot the interlocks before going on. See Control Module Port and LED Overview.
Laser Control LED
Clear the Table
Remove all flammable material from the table.
Watch the CO2 Laser Control LED
While the job runs, the CO2 laser control LED must light each time the system tells the laser to fire.
Note: No laser control LED? Check the artwork and job settings: on a dual-source machine the laser source must be set to CO2, the power must be above 0, and the artwork must be inside the artboard. Fix the interlock or laser control LED before going on.
Burn Mark at the X-Axis
Tape the X-Axis Beam Opening
Open the top door and move the carriage away from the left end of the X-axis. Put a piece of masking tape over the round opening at the left end of the rail, where the beam leaves mirror 3 and enters the work area toward the carriage (mirror 4).
This is the same on the Fusion Edge, Maker, Pro and Ascent.
Open Settings
Press reset twice to send the carriage home, then tap the gear icon at the top right of the display.
Fire the Laser
Close all doors, then tap Activate once.
Warning: Everyone in the room must wear laser safety glasses.
Burn Mark
The laser is firing and reaching the X-axis. Check the carriage optics: go to Part 2: Low Output.
No Burn Mark
Continue with the laser status LEDs below.
Laser Status LEDs
High Voltage: The next steps open the laser bay. Do not touch any area marked with the high-voltage symbol.
Remove the Laser Cover
Find the Status LEDs on the Laser
The laser has three status LEDs on its connector end, the end toward the right side of the machine (away from the periscope):
- Red: power to the laser.
- Green: interlocks active.
- Yellow: on only while the laser is told to fire.
The LEDs are the same on every laser, but their layout differs:
Check the Red and Green LEDs
The red and green LEDs on the laser must both be on.
Red and Green On
Continue with the burn test at the laser.
An LED Is Off
- No red LED: laser unplugged, damaged harness, damaged laser or power supply.
- No green LED: interlocks not engaged, or a damaged interlock or harness. If these do not match the interlock LEDs on the side panel, check the connection between the laser and the control board.
Burn at the Laser
Warning: This test fires the laser with a mirror removed. Everyone in the room must wear laser safety glasses.
Remove Mirror 1
Turn off the machine, then remove mirror 1, the first mirror after the laser.
Place Card Stock in the Mirror Mount
Put a piece of card stock in the empty mirror 1 mount, then turn the machine on and close all doors.
Fire the Laser
Open Settings > Alignment and tap Activate. Have a second person watch the yellow LED on the laser: it must light while Activate is pressed. You can also take a video of the LEDs.
Check the Card Stock
Take out the card stock and look for a burn mark. Reinstall mirror 1 and its covers when you are done.
Burn Mark on the Card
The laser works. The problem is in the beam path or optics: go to Part 2: Low Output.
No Burn Mark
If there is no burn mark directly outside the laser and all three laser LEDs work correctly, contact Epilog Technical Support.
Part 2: Low Output
Having to keep lowering speed and raising power can mean low output from the laser. Run a reference engraving first, then check optics, alignment and focus, comparing a new engraving after each section.
Reference Engraving
Load the Material Setting
Send the file to the Epilog Dashboard, then import the Anodized Aluminum setting from the materials library.
Load and Focus
Place a piece of 0.025″ anodized aluminum in the top left corner of the table, and set the table height with the manual focus gauge.
Record the CO2 Focus Value
Open the Focus menu and write down the CO2 Focus value.
Note: If the CO2 Focus value is above 0.04″ or below 0.01″, skip to Verify Focus.
Run the Reference Engraving
Close all doors and run the job. Label the engraving and keep it to compare against throughout this procedure.
Carriage Optics
Inspect the Lens and Carriage Mirror
Remove the lens and the carriage mirror, clean both sides, and check them for damage. Discolored or damaged optics must be replaced. See Optics Removal and Installation and Optics Cleaning.
Compare a New Engraving
Reinstall the optics and run the reference engraving again on an unused area of the aluminum. Compare it to the first engraving.
Improvement
Low output is resolved. Do a full optics cleaning, then repeat the test engraving.
No Improvement
Continue with Verify Alignment.
Verify Alignment
Install the Alignment Target
Check the Red Dot at Top Left
In Settings > Alignment, tap Top Left and turn on the red dot pointer. The red dot must be inside the center ring of the target.
Check the Red Dot at Bottom Right
Tap Bottom Right. The red dot must still be inside the center ring.
Tape the Target
With the carriage still at the bottom right, put masking tape over the target.
Fire a Test Pulse
Close all doors and tap Activate once.
Warning: Check the tape often so you do not burn through the target, and remove the target when you are done.
Compare the Red Dot and Burn Mark
The burn mark and the red dot must line up. If they do not, follow the full Alignment Procedure.
Improvement
If you adjusted the alignment, run the reference engraving again and compare. If it is better, low output is resolved.
No Improvement
Continue with Verify Focus.
Verify Focus
If the focus is off, the beam is wider at the material and the engraving looks weak. The Focus Calibration Wizard finds the table height that gives the brightest mark and saves it as the new CO2 focus.
Run the Focus Calibration Wizard
Follow the Focus Calibration Wizard article. In short: tap the gear icon, then Focus > CO2 Focus > Standard, load 0.025″ anodized aluminum, and let the machine engrave its numbered test pattern. Then enter the number of the brightest mark.
Note: Older firmware? The wizard needs firmware 1.1.2.1 or later. If you cannot update the firmware, skip the wizard and find the focus manually in the next step instead.
Older Firmware Only: Find Focus Manually
Skip this step if you ran the wizard. Send the reference engraving with the anodized aluminum setting and load a piece of anodized aluminum. Set the distance from the focus gauge hook on the carriage to the material:
- Single source (CO2 only): 2 5/8″ (66 mm). Close all doors and run the job.
- Dual source (CO2 and fiber): start the job, pause it, then set 2 7/8″ (73 mm). Close all doors and resume the job.
While the job runs, raise and lower the table and watch for the brightest mark, then write down the CO2 Focus value at that height.
Compare the Focus Value
Open the Focus menu and compare the new CO2 Focus value to the one you recorded for the reference engraving.
Compare a New Engraving
Run the reference engraving again with the new focus and compare it to the original.
Improvement
Low output is resolved.
No Improvement
If you skipped the optics or alignment sections, complete them. Otherwise the laser may have low output: contact Epilog Technical Support.
Before You Contact Support
If the laser still has no output or low output after these checks, contact Epilog Technical Support. Include photos of your test engravings, the red dot and burn mark, the LEDs, and the focus values you recorded.