Estimated Time: 2–5 Minutes | Skill Level: Basic The Autofocus Calibration Wizard allows the laser system to automatically determine the correct autofocus height using a calibrated reference surface. This process ensures accurate and consistent autofocus performance across supported materials. Running the Autofocus Calibration Wizard Open the Settings Menu (...)
Focus Calibration Wizard
Estimated Time: 5–10 Minutes | Skill Level: Basic The Focus Calibration Wizard allows the laser system to automatically determine the optimal focal height for the installed lens. This process engraves a test pattern on anodized aluminum and identifies the focus position that produces the brightest mark. Running the (...)
Manual Focus Gauge Calibration – Fusion Maker, Edge, Pro
This procedure outlines the steps required to calibrate the manual focus gauge after completing the Focus Calibration Wizard. Proper calibration ensures that the gauge accurately reflects the correct focal height determined using the Calibration Wizard. Note: The Calibration Wizard is available only on firmware version 1.1.2.1 or later. To update (...)
IRIS Camera Calibration Guide
Estimated Time: 20–40 Minutes • Skill Level: Intermediate Important: All focus calibration procedures must be completed before performing a camera calibration to ensure accurate results. Click the tabs below to switch between machine types. Each tab shows the camera calibration procedure specific to that machine. Overview & Requirements Fusion Edge (...)
Quick Guide: Calibrating the Joystick for Accurate Movement
Steps to Calibrate the Joystick Open the Settings Menu On the display panel, press the gear icon in the top-right corner to open the Settings menu. Image 1: Home screen with gear icon in top-right corner Access Advanced Settings Press and hold the word “Settings” on the screen until the (...)
Laser Alignment – Maker / Edge / Pro
Turn On To begin the laser alignment procedure, power on the laser. For the following procedures, the table will be broken into four (4) positions. Each position is identified by its relative distance to the laser source and corresponds with the mirror to adjust for that position. Three of the (...)
Focus Calibrations – Fusion Maker, Edge, and Pro
Please find the attachment for an in-depth description.
Fiber Alignment – Fusion Pro 32 & 48
This guide provides step-by-step instructions for performing precise laser alignment on the Fusion Pro CO2 and Fiber laser systems. Proper alignment ensures optimal engraving performance and reduces the risk of hardware damage. Whether you’re troubleshooting a drop in laser power or aligning after maintenance, this document will walk you through (...)
Touchpad Calibration – Fusion Maker, Edge, and Pro 24 and 36
Estimated time: 5 minutes • Skill: Basic Touchscreen calibration ensures accurate touch response when selecting options and settings on the display. This procedure is rarely required and should only be performed if the touchscreen is registering incorrect inputs or responding inconsistently. Touchscreen Calibration Procedure Open the Settings menu. At the (...)
Leveling the Table
This document outlines the table leveling procedure for the Fusion Maker, Edge, and Pro 24 and 36. Table level should be checked periodically to ensure that all areas of the table are the same distance from the focusing lens. If all areas of the table are not the same distance (...)
Adjusting the Home and Park Positions
This document outlines the home and park position adjustment procedures for the Fusion Maker, Fusion Edge, and Fusion Pro.
When to Calibrate the IRIS Camera System
Applies to: Fusion Maker • Fusion Edge • Fusion Pro • G100 All Fusion Maker, Edge, Pro, and G100 engravers are equipped with the IRIS™ camera system, which overlays your artwork onto the engraving table and material within the Epilog Dashboard software. The accuracy of this system depends on proper (...)