This guide covers leveling the table on the Fusion Maker, Fusion Edge and Fusion Pro 24 and 36: leveling the table tub at the lead screws, leveling the table inserts (Pro only), and confirming the level with autofocus.
Parts Required
- None
Tools / Materials Required
- 5/32" Allen Wrench
- 1/8" Allen Wrench
- 9/16" Wrench or Adjustable Wrench
- 11/16" Wrench or Adjustable Wrench
When to Level the Table
Table level should be checked periodically to keep the engraver working at its best. Level the table if:
- Laser power seems weak in certain areas of the table.
- The engraver cannot cut through material at or near the recommended settings in certain areas of the table.
- The engraver has been moved to a new location.
Leveling the Table Tub
Turn On Engraver
Turn on the engraver and let it finish starting up. Place a piece of flat material on the table.
Lower the Focus Gauge
Lower the manual focus gauge. Use the Focus menu to raise the table until the material touches the gauge.
Find the Low Corner
Use the Jog menu to move the lens carriage to each corner of the table and find which corner or corners are too low. The gauge should touch the material at every corner.
Remove the Rear Panel or Plenum
If a rear corner is low, remove the rear panel or the exhaust plenum.
Adjust the Low Corner
There is a table leveler on the lead screw at each corner of the table. Loosen the two Allen screws on either side of the lead screw, then turn the red lead screw nut (highlighted in purple) until the material touches the manual focus gauge.
Note: Pick a fixed reference point in the engraver cabinet and adjust every lead screw to line up with it.
Lock the Leveler
Tighten the two Allen screws on either side of the lead screw to lock the table leveler.
Recheck Every Corner
Jog the lens carriage to each corner again. The manual focus gauge should touch the table at every corner.
Leveling the Table Inserts (Pro Only)
Pro only Before you start, remove the engraving table insert and check it for damage, especially along the edges. A damaged table insert will keep you from completing this procedure.
Important: Do not do this procedure with the vector grid or slat assembly installed. It can damage the cutting grid or the manual focus gauge. Make sure the engraving table is installed.
Find the Low Corner
Use the Jog menu to move the lens carriage to each corner of the table and find which corner or corners are too low.
Remove the Panel or Plenum
If a front corner is low, remove the front access panel. If a rear corner is low, remove the rear panel or the exhaust plenum.
Table Insert Levelers
Each corner of the table has a table insert leveler screw and two locking screws.
Adjust the Insert Leveler
Loosen the two table insert leveler locking screws (circled in red), then tighten or loosen the table insert leveler screw until the table insert touches the manual focus gauge.
Lock the Insert Leveler
Tighten the two locking screws on either side of the table insert leveler screw.
Fine Tuning With Autofocus
Check With Autofocus
You can use autofocus to confirm the table level. Jog the lens carriage to each of the table locations used above and run an autofocus from the Focus menu.
Compare the Values
Compare the value returned at each location. If they are all within ±0.010, the table level is within specification.