Focus and camera calibrations keep the Fusion Galvo G100 at the correct focal height and keep the cameras accurate. Always complete the focus and camera calibrations together; skipping the camera calibration can leave the camera stream inaccurate and throw off artwork placement.
Parts Required
- GC0208 – Target, Camera Calibration, G100
Tools / Materials Required
- 8″ x 8″ Piece of Anodized Aluminum
- 1/8″ Allen Wrench
When to Calibrate
Complete this procedure if you notice any of the following:
- Laser power appears weak at the currently calibrated focal height
- Galvo platform movement does not match focus input, or the platform crashes
- Artwork placement with the IRIS camera system is inaccurate
It is also required after replacing any of these components:
- Z-Axis PCB
- Fiber laser
- Control module
- Galvo head assembly
- Overhead camera assembly
- Galvo lens
Note: The G100 uses two lenses: the F163 (4″ x 4″ field) and the F254 (6″ x 6″ field). Complete these calibrations with each lens installed. This guide shows the F254 lens; the F163 procedure is identical. Complete all six calibrations below in order, in one session.
Galvo Platform Calibration
The galvo platform moves from the top to the bottom of the z-axis, locating the magnetic sensors along the z-axis PCB. This step must be completed for an accurate focus calibration.
Finish the Calibration
Let the engraver complete the calibration. When Calibration done appears, press Done.
Fiber Focus Calibration
This calibration sets the focal height of the fiber laser and the manual focus gauge. You will run a small job while adjusting the galvo platform to find the correct focal height.
Create the Test Job
In your preferred illustrating program, create a black raster box about 2″ x 2″ (50 mm x 50 mm), and send it to the Software Suite.
Set the Job Settings
Set the Process Type to Hatch and use these settings:
- Speed: 100
- Power: 40
- Wave: 10
Run the Job
Send the job to the engraver. Place the anodized aluminum in the middle of the worktable, close the door, and press Go to start the job.
Find the Focal Height
Use the joystick to slightly raise and lower the galvo platform while watching the spark where the laser hits the aluminum. The correct focal height is where the spark is brightest.
Stop the Job
Let go of the joystick. Press Go/Stop to pause the job, then press Reset (circled in red) to stop it.
Open Settings Menu
Remove the anodized aluminum from the engraver, then press the gear icon to open the Settings menu.
Enter the Thickness
Make sure the Thickness box matches the material you just marked. For anodized aluminum supplied by Epilog Laser, enter 0.025.
Start the Calibration
Press Start. This calibration is very fast because the engraver simply saves the current position of the galvo platform.
Finish the Calibration
Let the engraver complete the calibration. A Calibration done message appears when it is finished.
Red Dot Diode Calibration
Turn On the Red Dot
Press the Focus button (circled in red) to turn on the focus cross hair and the focus red dot.
Check the Red Dot
With the galvo platform at the correct focal height (a focus reading of 0.00), the red dot should be in the center of the cross hair.
Adjust if Needed
If the red dot is not centered, adjust it by loosening or tightening the 1/8″ Allen screw on the underside of the red dot assembly.
F163 (4″ x 4″) Lens
If calibrating with the F163 lens installed, adjust the Allen screw shown by the arrow.
F254 (6″ x 6″) Lens
If calibrating with the F254 lens installed, adjust the Allen screw shown by the arrow.
Manual Focus Gauge Calibration
Check the Manual Focus Gauge
With the galvo platform at the correct focal height (a focus reading of 0.00), place the manual focus gauge in the bracket next to the lens. It should be fully seated in the bracket with its tip touching the worktable.
Adjust if Needed
If the gauge is not fully seated or does not touch the table, loosen the locking nut, then turn the adjustment nut to set the length. Tighten the locking nut when the length is correct.
Camera Calibration
Place the Calibration Mat
Place the camera calibration mat in the center of the worktable and hold it flat with four of the red-capped thumbscrews.
Let the Calibration Run
A camera feed appears on the display while the calibration runs. The feed will look skewed or slanted; this is normal and does not affect the calibration.
Check the Score
When the calibration finishes, a message shows the calibration score. Press OK.
Note: The score varies with lens type, lighting, and how flat the mat is. 1.2 or less is good, 1.2 – 1.7 is acceptable but marginal, and 1.8 or higher may prompt you to run the calibration again. For a poor score, make sure the focus calibrations were completed first, the mat is flat and undamaged, and nothing else is on the worktable.
Galvo Calibration
Place the Anodized Aluminum
Place an 8″ x 8″ piece of anodized aluminum in the center of the worktable and hold it flat with four of the red-capped thumbscrews.
Start the Calibration
Press OK to begin. The engraver marks the aluminum, then the cameras inspect the mark and adjust so the galvo and camera positioning systems line up.
Check the Score
When the calibration finishes, a message shows the calibration score.
Note: 1.8 or less is good, 1.9 – 2.5 is acceptable but marginal, and higher than 2.5 may prompt you to run the calibration again. For a poor score, make sure the focus calibrations were completed first, the aluminum is flat and has not been marked before, and nothing else is on the worktable.