Skip to main content
Calibrations
16000-17000

Filters


Getting Started (11)
Usage and Operation (108)
Service and Repair (122)

Filters


Getting Started (11)
Usage and Operation (108)
Service and Repair (122)

CO2 Laser Alignment – Fusion Pro 32 & 48

How do I align the CO2 laser in the Fusion Pro 32 and 48?

Introduction

This guide covers aligning the CO2 laser on the Fusion Pro 32 and 48. The alignment has three parts: a pre-alignment that makes the CO2 laser and red dot coaxial, the cutting laser (mirror) alignment, and the perpendicular alignment.

Parts Required

  • CS0935 – Holder, Target, Alignment

Tools / Materials Required

  • 5/32" Allen Wrench
  • 3/32" Allen Wrench
  • Masking Tape
  • Eyeglasses or Protective Eyewear

When to Align

Check the CO2 laser alignment periodically to keep the engraver at optimum performance. Complete this procedure if:

  • Laser power appears weak in certain areas of the table, especially moving from left to right.
  • The engraver cannot cut through materials at or around the recommended settings.
  • Optics in the lens assembly fail prematurely.
  • The engraver has been moved to a new location.

Or if any of these components have been replaced: the laser tube, mirror 1, 2 or 3, the X-axis assembly, or the red dot diode.

CO2 Laser Safety: The CO2 laser can cause serious or permanent injury if safety procedures are not followed. Do not fire the laser with any engraver panels removed, do not place any part of your body in the beam path while the laser is operating, and do not defeat the safety interlock system. Everyone present should wear eye protection, such as prescription eyeglasses or Lexan or other polycarbonate safety glasses, for the whole procedure.


Pre-Alignment

The pre-alignment makes sure the CO2 laser and the red dot diode are coaxial, so the red dot can be used to align the mirrors.

Step 1

Turn On Engraver

Turn on the engraver and let it complete the startup process.

Step 2

Install Alignment Target

Install the CS0935 laser alignment target over the window optic on the left side of the lens carriage, then place a piece of masking tape over the target.

Step 3

Open the Settings Menu

On the display, press the gear icon to open the Settings menu.

Step 4

Open Alignment Mode

Press Alignment to open the Alignment Mode menu, which moves the lens carriage to set table positions and fires the laser without sending a job. For lasers under 120 watts, press Bottom Right (position 4). For 120-watt lasers, press Center.

Step 5

Fire the Laser

Make sure the laser power is set to 10% and press Activate once to fire the laser. Look through the top door, or open it if needed, to see whether the laser marked the masking tape.

Step 6

If There Is No Mark

Close the top door, then press and hold Activate while watching the masking tape. Let go as soon as you see the laser mark the tape.

Note: If the alignment is very poor, you may not get a burn mark in position 4. In that case, try for a burn mark in position 1.

Step 7

Compare Red Dot and Burn Mark

Press the Red Dot Pointer button to turn on the red dot, then check where it falls in relation to the burn mark. For an accurate alignment, the red dot and the burn mark should be in exactly the same spot. If they are, skip to Cutting Laser Alignment.

Note: At this point, where the red dot and burn mark sit in relation to the center of the target does not matter.

Step 8

Locate the Red Dot Diode

If the red dot and burn mark are not in the same spot, remove the lower rear panel of the engraver and locate the red dot diode to the right of the laser tube.

Step 9

Adjust the Red Dot

Use the three Allen adjustment screws to center the red dot over the burn mark on the masking tape.

Step 10

Install Lower Rear Panel

Once the red dot and burn mark are in exactly the same spot, install the lower rear panel and continue to Cutting Laser Alignment.


Cutting Laser Alignment

Important: The laser and red dot must be coaxial before you begin. You cannot properly align the laser if they are not.

Reference

Table Positions

For alignment, the table is divided into four positions. Each position is checked with the carriage moved there in Alignment Mode.

Reference

Mirror Locations

The CO2-only Fusion Pro has four mirrors. Each one is matched to a table position, so always adjust the mirror for the position you are checking.

Mirror 1 location

Mirror 1 – Position 1

Mirror 2 location

Mirror 2 – Position 2

Mirror 3 location

Mirror 3 – Positions 3 & 4

Mirror 4 location

Mirror 4 – Perpendicular Alignment

Adjusting Mirror 1 (Position 1)

Step 11

Move to Position 1

Place a new piece of masking tape on the alignment target and make sure the red dot pointer is on. In Alignment Mode, press Top Left to move the lens carriage to position 1. If the red dot is not centered on the target, mirror 1 needs adjusting.

Step 12

Remove Lower Mirror Cover

Remove the lower mirror cover at the back left corner of the engraver.

Step 13

Adjust Mirror 1

Use the three Allen adjustment screws on the back of mirror 1 to center the red dot on the alignment target. The screw guide shows which way the dot moves as you turn each screw.

Adjusting Mirror 2 (Position 2)

Step 14

Move to Position 2

Make sure the red dot pointer is on. In Alignment Mode, press Bottom Left to move the lens carriage to position 2. If the red dot is not centered on the target, mirror 2 needs adjusting.

Step 15

Remove Upper Mirror Cover

Remove the upper mirror cover at the back left corner of the engraver.

Step 16

Adjust Mirror 2

Use the three Allen adjustment screws on the back of mirror 2 to center the red dot on the alignment target.

Step 17

Recheck Position 1

Move the carriage back to position 1. If the red dot is still centered, continue to Mirror 3. If not, readjust mirror 1, then move between positions 1 and 2, adjusting the matching mirror at each, until the red dot is centered at both.

Note: In some cases this takes several moves back and forth between positions. Make sure you are adjusting the correct mirror for each position.

Adjusting Mirror 3 (Positions 3 & 4)

Step 18

Move to Position 3

Make sure the red dot pointer is on. In Alignment Mode, press Top Right to move the lens carriage to position 3. If the red dot is not centered on the target, mirror 3 needs adjusting.

Step 19

Remove Left Panel

Remove the left panel of the engraver.

Step 20

Adjust Mirror 3

Use the three Allen adjustment screws on the back of mirror 3 to center the red dot on the alignment target.

Step 21

Recheck Positions 1 and 2

Move the carriage back to positions 1 and 2. If the red dot is still centered at both, continue to Perpendicular Alignment. If not, readjust mirror 1 or 2, then move between positions 1, 2 and 3, adjusting the matching mirror at each, until the red dot is centered at all three.

Note: In some cases this takes several moves back and forth between positions. Make sure you are adjusting the correct mirror for each position.


Perpendicular Alignment

Once the mirrors are aligned, adjust mirror 4 so the beam travels straight down and vector cuts are as close to 90 degrees as possible. This is especially important for customers who do a lot of cutting.

Important: Skipping the perpendicular alignment can result in poor vector performance and premature failure of the optics in the lens carriage.

Step 22

Raise the Table

Make sure the red dot pointer is on. Use the Focus menu to raise the table, stopping short of pressing in the autofocus plunger.

Step 23

Place Target on the Table

Remove the alignment target from the lens carriage and set it on the table directly under the lens tube. Move it until the red dot is centered on the target, then tape the target down so it cannot move.

Step 24

Lower the Table

Use the Focus menu to lower the table 3–4" (75–100 mm).

Step 25

Adjust Mirror 4

If the red dot is no longer centered on the target, use the adjustment screws on mirror 4 to center it.

Step 26

Verify While Raising

Raise the table while watching the red dot. If it moves off the center of the target, repeat these steps until the red dot stays put as the table is raised and lowered.

Finish Up

Remove the alignment target from the table and reinstall the mirror covers and the left panel before running jobs.

Was this helpful?

Yes
No
Thanks for your feedback!
  • ID:
    KA-01543
  • Date:
    11/03/2026