Skip to main content
Calibrations
16000-17000

Filters


Getting Started (11)
Usage and Operation (108)
Service and Repair (122)

Filters


Getting Started (11)
Usage and Operation (108)
Service and Repair (122)

Adjusting the Home and Park Positions

How do I adjust the home and park positions in the Fusion Maker, Fusion Edge, and Fusion Pro?

Introduction

This guide covers checking and adjusting the X and Y home position, the rotary home position and the park positions on the Fusion Maker, Fusion Edge and Fusion Pro 24, 32, 36 and 48.

Parts Required

  • None

Tools / Materials Required

  • Ruler, Measuring Tape or Calipers
  • Scrap material that marks well (anodized aluminum, wood or two-layer plastic)

X & Y Home Position Calibration

The X and Y home position sets the zero point the engraver works from, so artwork lands where you placed it. You do not need to calibrate it regularly. Calibrate it when artwork engraves or cuts in the wrong location, or after replacing any of these parts:

  • X- or Y-axis motor
  • X- or Y-axis home switch
  • Control board (in rare cases)

You need a ruler, measuring tape or calipers and a small piece of material at least 3" x 3" (75 mm x 75 mm). Wood, anodized aluminum or two-layer engraveable plastic work well.

Checking the Home Position

Step 1

Turn On Engraver

Turn on the engraver and let it finish starting up.

Step 2

Create the Test Box

In your preferred illustration program, set the artboard to the size of the engraver table. Draw a 1" x 1" (25 mm x 25 mm) vector box and place it 1" (25 mm) from the left edge and 1" (25 mm) from the top edge of the artboard.

Step 3

Send to the Software Suite

Send the job to the Epilog Software Suite.

Step 4

Place Material and Check Preview

Place the material in the upper-left corner of the table. In the Job Preview pane, make sure the box is still in the upper-left corner.

Important: Do not move the box with the Software Suite edit tools.

Step 5

Set the Job Parameters

Use these settings:

  • Power: high enough to leave a visible mark (cutting through is not needed)
  • Speed: 50%
  • Frequency: the recommended value for your material

Step 6

Run the Job

Send the job to the engraver and start it.

Step 7

Measure the Box

When the job is done, remove the material and measure from the left and top edges of the material to the left and top lines of the box. Both should be 1" (25 mm). If not, adjust the home position as described below.

Adjusting the Home Position

Step 8

Open the Settings Menu

On the display, press the gear icon to open the Settings menu.

Step 9

Open the Home Menu

Press Home.

Step 10

Note the Home Values

The Home menu shows the current X and Y home values.

Note: Adjust one axis at a time for an accurate calibration, and write down the current X and Y home values before you change them.

Reference

Which Way to Adjust

X-Axis Home

The x-axis home value is a negative number: the distance from the x-axis home switch on the right side of the x-axis assembly.

  • Decrease the value (more negative) to move the home position to the left.
  • Increase the value (more positive) to move the home position to the right.
Y-Axis Home

The y-axis home value is a positive number: the distance from the y-axis home switches at the rear of the engraver.

  • Decrease the value (closer to zero) to move the home position toward the rear of the engraver.
  • Increase the value to move the home position toward the front of the engraver.

Step 11

Enter a New Value

Press the axis you want to change and enter a new value on the pop-up keypad.

Step 12

Save and Home

Press the disk icon next to the X and Y home values to save the change, then press Home Axis so the engraver moves to the new home position.

Step 13

Rerun the Test Job

Place the material in the upper-left corner of the table again, open the Job menu and rerun the test job.

Step 14

Measure and Repeat

Measure again, and repeat the adjustment until the box is 1" (25 mm) from both the left and top edges of the material.


Rotary Home Position Calibration

The rotary home position sets the zero point for the rim drive and 3-jaw chuck fixtures. Calibrate it when artwork engraves in the wrong location on the rotary, or after replacing any of these parts:

  • X- or Y-axis motor
  • X- or Y-axis home switch
  • Control board (in rare cases)
  • Rotary motor, rotary PCB or the rotary itself

Checking the Home Position

Step 15

Turn On Engraver

With the rotary fixture installed, turn on the engraver and let it finish starting up.

Step 16

Turn On the Red Dot

Press the Red Dot Pointer button to turn on the red dot.

Step 17

Check the Rim Drive

On the rim drive, the red dot should sit in the position shown.

Step 18

Check the 3-Jaw Chuck

On the 3-jaw chuck, the red dot should sit in the position shown. If the red dot is not at the ideal position, adjust the rotary home position as described below.

Adjusting the Home Position

Step 19

Open the Settings Menu

On the display, press the gear icon to open the Settings menu.

Step 20

Open the Home Menu

Press Home.

Step 21

Note the Rotary Home Values

The Home menu shows the X and Y rotary home values for the fixture that is installed (the rim drive is shown here).

Note: Adjust one axis at a time for an accurate calibration, and write down the current X and Y home values before you change them.

Reference

Which Way to Adjust

X-Axis Home

The x-axis home value is a negative number: the distance from the x-axis home switch on the right side of the x-axis assembly.

  • Decrease the value (more negative) to move the home position to the left.
  • Increase the value (more positive) to move the home position to the right.
Y-Axis Home

The y-axis home value is a positive number: the distance from the y-axis home switches at the rear of the engraver.

  • Decrease the value (closer to zero) to move the home position toward the rear of the engraver.
  • Increase the value to move the home position toward the front of the engraver.

Step 22

Enter a New Value

Press the axis you want to change and enter a new value on the pop-up keypad.

Step 23

Save and Home

Press the disk icon next to the X and Y home values to save the change, then press Home Axis so the engraver moves to the new home position.

Step 24

Repeat Until Correct

Repeat the adjustment until the red dot sits in the ideal position shown above.


Park Positions

The park position is where the carriage sits while the engraver is idle. You can move it to make it easier to place material on the table or in a rotary fixture. It is separate from the home positions, and changing it does not affect where the engraver engraves or cuts.

Note: This procedure applies to the park positions for the flat table, the rim drive and the 3-jaw chuck.

Step 25

Open the Settings Menu

On the display, press the gear icon to open the Settings menu.

Step 26

Open Expanded Settings

Press the gear and wrench icon in the lower left corner to open the expanded settings menu.

Step 27

Find the Flat Table Park Position

Expand the System Settings tab and swipe down to Park Position. Use this setting when no rotary is installed.

Step 28

Or Find the Rotary Park Position

When a rim drive or 3-jaw chuck is installed, use the Park Position setting under Rotary instead.

Reference

Park Position Values

Unlike the home values, which measure from the home switches, the park position values measure from the X and Y home position. Both are positive numbers.

  • X (first number): decrease it (closer to zero) to move the park position left; increase it to move it right.
  • Y (second number): decrease it (closer to zero) to move the park position toward the rear; increase it to move it toward the front.

Step 29

Enter New Values

Press the park position setting and enter new X and Y values on the pop-up keypad.

Step 30

Save and Park

Press OK to save the change, then press Park Axis so the engraver moves to the new park position.

Step 31

Repeat as Needed

Repeat until the carriage parks where you want it.

Was this helpful?

Yes
No
Thanks for your feedback!
  • ID:
    KA-01546
  • Date:
    11/03/2026

Continue Your Laser Journey

Revisit a past lesson or move ahead to discover what's next.