This guide covers replacing the complete x-axis assembly on the Fusion Pro 32 and 48. The x-axis assembly contains circuit boards, cameras and a motor, so after installation the carriage camera and the engraver peripherals are updated from the display.
Parts Required
- CS0400 – Assy, X-Axis Rail, 32×20 (Fusion Pro 32)
- CS1200 – Assy, X-Axis Rail, 48×36 (Fusion Pro 48)
Tools Required
- 5/32" and 7/64" Allen Wrenches
- 5/16" Nut Driver
- Phillips Screwdriver
Safety First: Ensure the engraver is completely powered off and the power cord is disconnected before removing any panels or touching internal components.
X-Axis Assembly Removal
Turn Off Engraver
Turn off the engraver.
Remove Side Panels
Remove the left and right panels of the engraver by loosening the 5/32" cam locks.
Loosen Lens Tube Collar
Loosen the Phillips screw on the lens tube retaining collar (circled in red). Hold the lens tube so it does not fall.
Remove Bellows
Remove the left and right bellows and the backing plate by loosening the six 5/16" nuts.
Loosen Drive Board Cover Screws
Loosen, but do not remove, the four Phillips screws that hold the x-axis drive board cover (circled in red).
Remove Drive Board Cover
Remove the x-axis drive board cover.
Disconnect Drive Board Connectors
Disconnect the seven electrical connectors from the x-axis drive board (red arrows).
Disconnect Air Tubing
Disconnect the air tubing from the elbow connector on the right side of the x-axis assembly (highlighted in purple).
Note: The air tubing is held by a retaining fixture. Press the tubing into the fixture, then hold the orange retaining ring against the fixture and pull the tubing away from it.
Remove Drive Board Housing Screws
Loosen and remove the four 7/64" hex screws that hold the x-axis drive board housing (circled in red).
Remove X-Axis Fasteners
Remove or loosen the four 5/32" fasteners that secure the x-axis assembly to the y-axis bearings: two on the right side (top) and two on the left side (bottom).
Lift the X-Axis Assembly
Lift the x-axis assembly up to clear the locator pins on the left and right y-axis bearing blocks.
Remove the X-Axis Assembly
Slide the x-axis assembly out of the engraver through the right side.
X-Axis Assembly Installation
Install the New X-Axis Assembly
Slide the new x-axis assembly into the engraver through the right side of the machine: CS0400 for the Fusion Pro 32 or CS1200 for the Fusion Pro 48.
Seat on the Bearing Blocks
Place the x-axis assembly on the y-axis bearing blocks, making sure the locator pins go into the upper bearing block assembly.
Install X-Axis Fasteners
Install or tighten the four 5/32" fasteners that secure the x-axis assembly to the y-axis bearings: two on the right side and two on the left side.
Position Drive Board Housing
Position the x-axis drive board housing over its mounting holes.
Install Drive Board Housing Screws
Install and tighten the four 7/64" hex screws that hold the x-axis drive board housing.
Reconnect Air Tubing
Reconnect the air tubing to the elbow fitting on the right side of the x-axis assembly.
Note: Insert the tubing into the collar of the retaining fixture, then gently pull on it to make sure it is secure.
Reconnect Drive Board Connectors
Reconnect the seven electrical connectors to the x-axis drive board.
Note: Each connector on the drive board is unique and only fits one receptacle.
Install Drive Board Cover
Install the x-axis drive board cover and tighten the four Phillips screws.
Install Bellows
Install the backing plate and bellows. Install and tighten the six 5/16" nuts that hold them in place.
Insert the Lens Tube
Insert the lens tube in the lens assembly with the notch in the tube facing the rear of the engraver (red arrow). Hold the lens tube so it does not fall.
Updating the Carriage Camera
Wait for Success
Let the engraver finish the update. A success message appears when it is done.
Updating the Peripherals
Open the Settings Menu
On the display, press the gear icon in the upper right corner to open the Settings menu.
Update Motor Drives and FPGA
Select Motor Drives and FPGA, then press Update.
Important: Do not power off the engraver during the update. It is normal for the display to turn off while the update runs. When the update has been applied, the engraver prompts you to restart.
Restart When Prompted
When the engraver prompts you to restart, power cycle the engraver.
Calibrate and Align
After replacing the x-axis assembly, complete a full focus calibration and laser alignment.