This guide covers checking and adjusting the table level on the Zing, so the laser delivers even power across the whole engraving area.
Parts Required
- None
Tools Required
- 3/32" Allen Wrench
- Adjustable Wrench
Checking the Table Level
Press Focus
With the engraver on and no material in it, press the Focus button on the keypad.
Lower the Focus Stylus
Lower the focus stylus and slide it all the way to the right side of the engraving area.
Note: To tell whether the table is in focus, swing the stylus. It should tap against the table but not get stuck.
Focus the Table
Use the Up and Down arrow keys to raise or lower the table until it barely touches the focus stylus.
Power Off Engraver
Turn off the engraver.
Check Each Corner
Move the focus stylus to each corner of the table. The table should be in focus at every corner. If a corner is not, continue to the next section.
Adjusting the Table Level
Locate the Lead Nut Clamp
Find the lead nut clamp at the corner you need to adjust. There is one at each corner of the table.
Loosen the Clamp Screw
Reaching under the table through the front door, loosen the lead nut clamp screw with a 3/32" Allen wrench until it spins freely.
Turn the Lead Nut
Turn the plastic lead nut by hand, or with an adjustable wrench, until the focus stylus is just touching the table.
Repeat for Each Corner
Repeat this section for every corner that is out of level, then check all four corners again.