This guide covers tensioning the X-axis belt on the Fusion and Fusion M2, for positioning errors caused by the belt slipping.
Parts Required
- None
Tools Required
- 7/32" Allen Key
- 7/64" Allen Key
Safety First: Ensure the engraver is completely powered off and the power cord is disconnected before removing any panels or touching internal components.
Before You Start: Contact Epilog Technical Support before tensioning the X-axis belt.
Tensioning the X-Axis Belt
Power Off Engraver
Turn off the engraver.
Remove the Upper Left Panel
Turn the two black Allen screws on the upper left panel about 3/4 turn clockwise with a 7/32" Allen key, and the panel releases. Remove the panel and set it aside.
Loosen the Top Mounting Screws
Find the mirror and pulley block on the left end of the X-axis arm. Two of its four pulley mounting screws are on top of the block. Loosen these two screws with a 7/64" Allen key.
Important: Loosen these screws only. Do not remove them.
Loosen the Remaining Mounting Screws
The other two mounting screws are reached through the two access holes in the block (circled). Loosen them with the 7/64" Allen key.
Important: Loosen these screws only. Do not remove them.
Turn the Tensioner Screw
Find the tensioner screw inset into the left end of the mirror and pulley block. Turn it clockwise one full turn with the 7/64" Allen key.
Tighten the Mounting Screws
Tighten all four mounting screws on the mirror and pulley block to hold the belt tension in place.
Replace the Upper Left Panel
Reinstall the upper left panel and turn the two Allen screws back to lock it.