This guide covers leveling the table on the Fusion Pro 32 and 48: leveling the table tub at the lead screws, fine tuning the engraving table inserts, and confirming the level with autofocus.
Parts Required
- None
Tools Required
- 5/32" Allen Wrench
When to Level the Table
Table level should be checked periodically so that every area of the table is the same distance from the focusing lens. If it is not, you can see a loss of laser power and inconsistent engraving and cutting. Level the table if:
- Laser power seems weak in certain areas of the table.
- The engraver cannot cut through material at or near the recommended settings in certain areas of the table.
- The engraver has been moved to a new location.
Leveling the Table Tub
Turn On Engraver
Turn on the engraver and let it finish starting up. Make sure the engraving tables are installed.
Lower the Focus Gauge
Lower the manual focus gauge. Use the Focus menu to raise the table until it touches the gauge.
Find the Low Corner
Use the Jog menu to move the lens carriage to each corner of the table and find which corner or corners are lower. On a level table, the gauge touches the table at every corner.
Locate the Table Levelers
There is a table leveler at the lead screw in each corner of the table.
Adjust the Low Corner
Loosen the two Allen screws on either side of the lead screw (circled in red), then turn the lead screw nut until that corner of the table touches the manual focus gauge.
Recheck Every Corner
Jog the lens carriage to each corner again. The manual focus gauge should touch the table at every corner.
Leveling the Engraving Table Inserts
Before you start, remove the engraving table and check it for damage, especially along the edges. A damaged or warped table can keep you from finishing this procedure. Put the table back in the engraver when you are done inspecting it.
The Fusion Pro 32 has four adjustment points and the Fusion Pro 48 has eight, because of the Pro 48’s modular table. The adjustment screws are under the front access panel and the exhaust plenum. The drawings show a Fusion Pro 48, but the same steps apply to the Pro 32.
Facing the front of the engraver
- Left screws: left side of the left table.
- Center screws: right side of the left table and left side of the right table.
- Right screws: right side of the right table.
Facing the rear of the engraver
- Left screws: right side of the right table.
- Center screws: right side of the left table and left side of the right table.
- Right screws: left side of the left table.
Check Positions 1 and 2
From the rear of the engraver, with the focus gauge touching the table, move the lens carriage between positions 1 and 2 and watch that the gauge stays in contact with the table.
Positions 1 and 2
Loosen the Clamp Screws
If this area needs adjusting, loosen the table clamp locking screws for positions 1 and 2.
Adjust the Leveling Screws
Raise or lower the table with the Allen-head leveling screws until the tip of the manual focus gauge stays in contact with the table as you move between the positions.
Important: At the rear of the engraver, tightening a leveling screw lowers the table and loosening it raises the table.
Repeat for Positions 3 and 4
Move the lens carriage between positions 3 and 4 and check the gauge. If needed, repeat the loosen, adjust and tighten process using the screws shown below.
Important: At the rear of the engraver, tightening a leveling screw lowers the table and loosening it raises the table.
Positions 3 and 4
Repeat for Positions 5 and 6
When the rear is level at positions 1 to 4, move to the front of the engraver. Move the lens carriage between positions 5 and 6, check the gauge and adjust if needed using the screws shown below.
Important: The front leveling screws work the opposite way from the rear ones: at the front, tightening a screw raises the table and loosening it lowers the table.
Positions 5 and 6
Repeat for Positions 7 and 8
Move the lens carriage between positions 7 and 8, check the gauge and adjust if needed using the screws shown below. Tighten the clamp locking screws when you are done.
Important: The front leveling screws work the opposite way from the rear ones: at the front, tightening a screw raises the table and loosening it lowers the table.
Positions 7 and 8
Check for Rocking
Press down on each corner of both engraving table inserts. They should not rock. If they do, repeat the leveling procedure.
Fine Tuning With Autofocus
Check With Autofocus
You can use autofocus to confirm the table level. Jog the lens carriage to each of the table locations used above and run an autofocus from the Focus menu.
Compare the Values
Compare the value returned at each location. If they are all within ±0.010, the table level is within specification.