Skip to main content
Calibrations
16000-17000

Filters


Getting Started (11)
Usage and Operation (108)
Service and Repair (122)

Filters


Getting Started (11)
Usage and Operation (108)
Service and Repair (122)

Leveling the Table

How do I level the table in the Fusion Maker, Edge, and Pro 24 and 36?

Introduction

This guide covers leveling the table on the Fusion Maker, Fusion Edge and Fusion Pro 24 and 36: leveling the table tub at the lead screws, leveling the table inserts (Pro only), and confirming the level with autofocus.

Parts Required

  • None

Tools / Materials Required

  • 5/32" Allen Wrench
  • 1/8" Allen Wrench
  • 9/16" Wrench or Adjustable Wrench
  • 11/16" Wrench or Adjustable Wrench

When to Level the Table

Table level should be checked periodically to keep the engraver working at its best. Level the table if:

  • Laser power seems weak in certain areas of the table.
  • The engraver cannot cut through material at or near the recommended settings in certain areas of the table.
  • The engraver has been moved to a new location.

Leveling the Table Tub

Step 1

Turn On Engraver

Turn on the engraver and let it finish starting up. Place a piece of flat material on the table.

Step 2

Lower the Focus Gauge

Lower the manual focus gauge. Use the Focus menu to raise the table until the material touches the gauge.

Step 3

Find the Low Corner

Use the Jog menu to move the lens carriage to each corner of the table and find which corner or corners are too low. The gauge should touch the material at every corner.

Step 4

Remove the Front Panel

If a front corner is low, remove the front access panel.

Step 5

Remove the Rear Panel or Plenum

If a rear corner is low, remove the rear panel or the exhaust plenum.

Step 6

Adjust the Low Corner

There is a table leveler on the lead screw at each corner of the table. Loosen the two Allen screws on either side of the lead screw, then turn the red lead screw nut (highlighted in purple) until the material touches the manual focus gauge.

Note: Pick a fixed reference point in the engraver cabinet and adjust every lead screw to line up with it.

Step 7

Lock the Leveler

Tighten the two Allen screws on either side of the lead screw to lock the table leveler.

Step 8

Recheck Every Corner

Jog the lens carriage to each corner again. The manual focus gauge should touch the table at every corner.


Leveling the Table Inserts (Pro Only)

Pro only Before you start, remove the engraving table insert and check it for damage, especially along the edges. A damaged table insert will keep you from completing this procedure.

Important: Do not do this procedure with the vector grid or slat assembly installed. It can damage the cutting grid or the manual focus gauge. Make sure the engraving table is installed.

Step 9

Find the Low Corner

Use the Jog menu to move the lens carriage to each corner of the table and find which corner or corners are too low.

Step 10

Remove the Panel or Plenum

If a front corner is low, remove the front access panel. If a rear corner is low, remove the rear panel or the exhaust plenum.

Reference

Table Insert Levelers

Each corner of the table has a table insert leveler screw and two locking screws.

Table Insert Leveler Screw

Table Insert Leveler Screw

Table Insert Leveler Locking Screws

Table Insert Leveler Locking Screws

Step 11

Adjust the Insert Leveler

Loosen the two table insert leveler locking screws (circled in red), then tighten or loosen the table insert leveler screw until the table insert touches the manual focus gauge.

Step 12

Lock the Insert Leveler

Tighten the two locking screws on either side of the table insert leveler screw.


Fine Tuning With Autofocus

Step 13

Check With Autofocus

You can use autofocus to confirm the table level. Jog the lens carriage to each of the table locations used above and run an autofocus from the Focus menu.

Step 14

Compare the Values

Compare the value returned at each location. If they are all within ±0.010, the table level is within specification.

Was this helpful?

Yes
No
Thanks for your feedback!