X-Axis Drive Board Replacement – Fusion Pro / Edge

This document details how to replace the TE0104 X-Axis Drive Board on the 17000 Edge and Pro machines.

Introduction

This guide will walk you through the process of removing, installing, and programming the X-Axis Drive Board for Fusion Edge and Pro 24 / 36 models. Proper precautions, including the use of an anti-static strap, are essential to ensure the safe handling of electronic components.

Drive Board Replacement Procedure

Models: Edge 12, 24 & 36, Pro 24 & 36

Important: An anti-static strap is required when working with any PCB to prevent static discharge damage.

  • Using the Anti-Static Strap

    1. Remove the anti-static strap from packaging.
    2. Place around your wrist and adjust for comfort.
    3. Ensure the clamp is closed and the metal plate contacts your skin.
    4. Attach the alligator clip to bare metal on the engraver chassis.
    5. Preferred location: chassis bolt connected to the ground behind the right panel.

      grounding location

  • X-Axis Drive Board Removal

    1. Turn off and unplug the engraver.
    2. Remove the right panel of the engraver.

      remove right side panel

    3. Loosen (do not remove) 4 Phillips screws on the drive board cover.

      loosen board cover screws

    4. Remove the drive board cover.

      remove drive board cover

    5. Wear anti-static strap and connect to a grounded surface.
    6. Remove 6 electrical connections on the drive board.

      remove cables

    7. Remove 5 Phillips screws holding the board.

      remove screws

    8. Remove the x-axis drive board.

      remove board

  • X-Axis Drive Board Installation

    1. Wear anti-static strap and ground yourself.

    2. Install new drive board and secure with 5 Phillips screws.

      install screws

    3. Reconnect 6 electrical connections.

      connect cables

    4. Reattach the drive board cover and tighten the 4 screws.

      install drive board cover

    5. Replace the right panel and reconnect power.

      install right side panel

  • Programming the X-Axis Drive Board

    1. At the display panel, press the gear icon in the upper right-hand corner of the display to open the Settings menu:

      screenshot

    2. Press Update:

      screenshot

    3. Press Program Peripherals:

      screenshot

    4. Once in the Peripheral Update menu, select all available components and press Update:

      screenshot

    5. Allow the engraver to run the update process.

      Warning: When running a peripheral update, do not power off the engraver. During a peripheral update, it is common for the display to power off. Once the update has been applied, the engraver will prompt to restart.

    6. Once the engraver prompts you to restart, power cycle the engraver.
  • ID:
    KA-01669
  • Date:
    04/17/2025

Tools:

  • 5/32” Hex Wrench
  • Phillips Head Screwdriver
  • Anti-Static Wrist Strap

Parts & Resources:

  • TE0104 - PCB, Servo Motor Drive